1. Prodotto finitoview
The DewinLVD KWS-303 is a versatile 8-in-1 smart digital electric meter designed for DIN rail installation. It provides comprehensive monitoring of electrical parameters and includes multiple protection features to ensure safety and efficient power management. This device is suitable for a wide range of applications including industrial, commercial, and residential settings.
Caratteristiche principali:
- Misurazione 8 in 1: Visualizza contemporaneamente Voltage, Current, Power, Electricity (kWh), Frequency, Power Factor, Time, and Temperature.
- Protezione completa: Caratteristiche overvoltage, sottovoltage, protezione da sovracorrente e sovratemperatura.
- Display LCD ad alta definizione: Clear, colorful 178-degree viewing angle display with backlight for visibility day and night.
- One-Touch Zero Reset: Easily reset current and timer measurements for accurate data tracking.
- Archiviazione automatica dei dati: Retains the last test data during power outages and resumes data collection upon power restoration.
- Installazione su guida DIN: Convenient and secure 35mm DIN rail mounting.
- Costruzione durevole: Made from high-quality flame-retardant PC material for safety and reliability.

Image 1.1: The DewinLVD KWS-303 meter's display showing 8 electrical parameters and its one-click reset function.

Immagine 1.2: Es.amples of where the KWS-303 meter can be utilized, including industrial facilities, commercial markets, educational institutions, and laboratories.
2. Informazioni sulla sicurezza
Si prega di leggere attentamente tutte le istruzioni di sicurezza prima di installare o utilizzare il dispositivo. La mancata osservanza di queste istruzioni può causare scosse elettriche, incendi o lesioni gravi.
- Personale qualificato: L'installazione e la manutenzione devono essere eseguite solo da elettricisti qualificati.
- Disconnessione dell'alimentazione: Scollegare sempre l'alimentazione dal circuito prima di procedere all'installazione, al cablaggio o alla manutenzione.
- Cablaggio corretto: Assicurarsi che tutti i collegamenti elettrici siano sicuri e conformi alle normative elettriche locali.
- Voltage Valutazione: Non superare il volume specificatotage valori nominali di corrente del dispositivo.
- Ambiente: Installare il dispositivo in un luogo asciutto e ben ventilato, lontano dalla luce solare diretta, da alte temperature e da gas corrosivi.
- Messa a terra: Ensure proper grounding if required by local regulations.
3. Specifiche
The following table details the technical specifications of the DewinLVD KWS-303 Smart Digital Electric Meter:
| Parametro | Valore |
|---|---|
| Nome del prodotto | Rail Type Digital Measuring Meter |
| Materiale | PC ignifugo |
| Voltage Gamma | CA 85-290 V |
| Intervallo attuale | 0-40A |
| Intervallo di potenza | 0-12 kW |
| Gamma di elettricità | 0-9999 kWh |
| Gamma di frequenza | Frequenza |
| Fattore di potenza | 0-1PF |
| Intervallo di tempo | 99 giorni |
| Intervallo di temperatura | -20°C a 150°C |
| Funzione di memoria di spegnimento | SÌ |
| Zero Current Function | SÌ |
| Timer Zero Reset Function | SÌ |
| Metodo di installazione | Guida DIN da 35 mm |
| Dimensioni (L×W×H) | Dimensioni: 8.2 × 5 × 2.5 centimetri |
| Peso | 110g |
| Numero di modello | Il KWS-303 |
| Colore | Blu |

Image 3.1: Visual representation of the meter's dimensions and a summary of its key specifications.
4. Configurazione e installazione
The KWS-303 meter is designed for easy installation on a standard 35mm DIN rail. Follow these steps carefully:
- Disconnessione dell'alimentazione: Before starting, ensure that the main power supply to the circuit where the meter will be installed is completely disconnected. Use appropriate lockout/tagle nostre procedure.
- Montaggio: Fissare il misuratore su una guida DIN standard da 35 mm nel quadro elettrico. Assicurarsi che sia fissato saldamente.
- Cablaggio: Connect the input and output wires according to the diagram below.
- Collegare il Zero Line In (N) to the neutral wire from the power source.
- Collegare il Fire Line In (L) to the live wire from the power source.
- Collegare il Zero Line Out (N) to the neutral wire of the load.
- Collegare il Fire Line Out (L) to the live wire of the load.
- Ensure the temperature sensing interface (NTC) is connected if temperature monitoring is desired.
- Verifica connessioni: Double-check all wiring connections for correctness and tightness to prevent loose contacts and potential hazards.
- Ripristina alimentazione: Once installation is complete and verified, restore power to the circuit. The meter display should illuminate.

Image 4.1: Detailed wiring diagram and display parameter labels for the KWS-303 meter.
5. Istruzioni per l'uso
The KWS-303 meter provides real-time monitoring and protection. Here’s how to operate its main functions:
5.1 Display e navigazione
Upon power-up, the HD LCD screen will display all 8 measurement parameters simultaneously. The display is designed for a 178-degree viewing angle, ensuring readability from various positions.
5.2 One-Touch Zero Reset Function
The meter features a convenient one-touch zero reset function for specific parameters:
- Per reimpostare il Electricity (kWh) reading: Press and hold the designated reset button (refer to the device's physical buttons, typically marked with a reset icon or '–' button for specific models) until the kWh value resets to zero.
- Per reimpostare il Tempo measurement: Similarly, press and hold the appropriate button to reset the accumulated time.
This function is useful for monitoring energy consumption or operation time over specific periods.
5.3 Conservazione dei dati
The KWS-303 meter automatically saves the last recorded test data. In the event of a power outage, the data is retained. When power is restored, the meter will continue to accumulate data from the last saved point, preventing data loss.

Image 5.1: The meter's data storage feature, ensuring continuity of measurement data even after power interruptions.
5.4 Funzionalità di protezione
The meter incorporates several protection mechanisms to safeguard your electrical system and connected devices:
- Sovravoltage Protezione: Disconnette automaticamente il circuito se il voltage exceeds a safe threshold.
- Sottovoltage Protezione: Disconnects the circuit if the voltage scende al di sotto di un minimo di sicurezza.
- Protezione da sovracorrente: Trips the circuit if the current draw exceeds the rated ampetà (40A).
- Protezione da sovratemperatura: Shuts down the circuit if the internal temperature or sensed external temperature (if NTC is connected) becomes dangerously high.
These protection features help prevent damage to appliances and ensure electrical safety. The meter will typically display an error code or indicator when a protection event occurs.

Image 5.2: The KWS-303 meter's integrated protection functions for enhanced electrical safety.
6. Manutenzione
To ensure the longevity and accurate operation of your DewinLVD KWS-303 meter, follow these simple maintenance guidelines:
- Pulizia: Regularly wipe the meter's exterior with a soft, dry cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the display or casing.
- Ispezione: Periodically inspect the wiring connections to ensure they remain tight and free from corrosion. Check for any signs of physical damage to the meter.
- Ambiente: Ensure the operating environment remains within the specified temperature and humidity ranges. Avoid exposing the meter to excessive dust or moisture.
- Nessuna parte riparabile dall'utente: The meter contains no user-serviceable parts. Do not attempt to open or repair the device yourself, as this will void the warranty and could lead to electric shock.
7. Risoluzione Dei Problemi
If you encounter issues with your KWS-303 meter, refer to the following common troubleshooting steps:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il display è vuoto | Nessuna alimentazione; Cablaggio allentato; Malfunzionamento del dispositivo. | Check main power supply. Verify all wiring connections are secure. If power is present and wiring is correct, contact support. |
| Letture errate | Improper wiring; Sensor issue; Device malfunction. | Review wiring diagram (Image 4.1) and ensure correct connections. Check if the NTC temperature sensor is properly connected. Contact support if issues persist. |
| Protection trip (e.g., power cut off) | Sovravoltage, sottovoltage, overcurrent, or overtemperature condition detected. | Identify and resolve the underlying electrical issue (e.g., reduce load, check power supply stability, ensure proper ventilation). The meter will typically reset automatically once the condition is resolved, or may require a manual power cycle. |
| Reset function not working | Button not pressed correctly; Device malfunction. | Ensure the reset button is pressed and held for the required duration. If still unresponsive, contact support. |
Se non riesci a risolvere un problema seguendo questi passaggi, contatta l'assistenza clienti per ulteriore assistenza.
8. Garanzia e supporto
The DewinLVD KWS-303 Smart Digital Electric Meter is covered by a manufacturer's warranty against defects in materials and workmanship. Specific warranty terms and duration may vary by region and retailer. Please retain your proof of purchase for warranty claims.
Assistenza clienti:
For technical assistance, warranty inquiries, or to report any issues, please contact your retailer or the manufacturer directly. Refer to the product packaging or the official DewinLVD websito per le informazioni di contatto.
Quando contatti l'assistenza, tieni a portata di mano le seguenti informazioni:
- Product Model: KWS-303
- Data di acquisto
- Descrizione del problema