Aiphone VM-RMT

Aiphone VM-RMT Residential Fire Alarm Compatible Monitor Security Master Unit

Manuale di istruzioni

1. Introduzione

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Aiphone VM-RMT Residential Fire Alarm Compatible Monitor Security Master Unit. Please read this manual thoroughly before using the product and retain it for future reference.

2. Informazioni sulla sicurezza

To prevent injury to users or others, and to avoid property damage, please observe the following safety precautions. Incorrect operation due to disregard of instructions may cause harm or damage.

  • Sicurezza elettrica: Ensure the unit is connected to an AC100V 50/60Hz power supply. Do not attempt to open or repair the unit yourself. Refer all servicing to qualified personnel.
  • Installazione: Installation should be performed by a qualified technician. Ensure the unit is securely mounted according to the provided mounting dimensions to prevent it from falling.
  • Ambiente: Do not expose the unit to direct sunlight, high humidity, extreme temperatures, or corrosive environments. Operate within the specified temperature range of 0°C to 40°C.
  • Pulizia: Scollegare l'alimentazione prima della pulizia. Utilizzare un panno morbido e asciutto. Non utilizzare detergenti liquidi o spray.
  • Bottone di emergenza: Familiarize yourself with the location and function of the emergency button for immediate use in critical situations.

3. Prodotto finitoview

The Aiphone VM-RMT is a residential security master unit featuring a monitor for fire alarm compatibility. It includes various indicators and controls for security and communication functions.

3.1 Esterno View e componenti

The diagram below illustrates the external features and key components of the VM-RMT unit.

Diagram showing the external view, mounting dimensions, and specifications of the Aiphone VM-RMT security master unit.

Descrizione dell'immagine: This diagram provides a detailed technical drawing of the Aiphone VM-RMT unit. It includes an external view with dimensions (260mm height, 180mm width, 33.8mm depth), indicating the locations of the monitor (touch panel), emergency button, power LED, status LED, microphone, speaker, OFF button, and TALK button. Below this, a mounting diagram shows the recommended installation dimensions and a mounting height of approximately 1,400mm from the floor. The bottom section details the product specifications in a table format, covering power, consumption, display type, pixel count, weight, operating temperature, mounting type, compatible box, material, color, and included accessories.

  • Monitor (Touch Panel): 7-inch TFT LCD display for visual information and interaction.
  • Bottone di emergenza: For immediate activation of emergency alerts.
  • Power (Green) LED: Indica che l'unità è accesa.
  • Status (Red) LED: Indicates alarm or error conditions.
  • Microfono: For two-way communication.
  • Oratore: For audio output and communication.
  • Pulsante SPENTO: To turn off specific functions or silence alarms.
  • Pulsante PARLA: To initiate or respond to communication.

4. Configurazione e installazione

Proper installation is crucial for the optimal performance and safety of the VM-RMT unit. It is recommended that installation be performed by a qualified professional.

4.1 Montaggio

The unit is designed for wall mounting. Use a JIS2 standard switch box with a separator for installation. The recommended mounting height is approximately 1,400mm from the floor to the center of the unit.

4.2 Schema elettrico

The following diagram illustrates the necessary wiring connections for the VM-RMT unit, including power, external sensors, and auxiliary devices.

Wiring diagram for the Aiphone VM-RMT security master unit, showing connections to various sensors and devices.

Descrizione dell'immagine: This detailed wiring diagram for the Aiphone VM-RMT residential security master unit shows connections for the main unit to various external components. It illustrates the power supply (AC100V), connections to gas/CO sensors (up to 3 units), auxiliary sounders (up to 2 units), water leak sensors, fire sensors, call buttons, and other security sensors. It also shows connections for a camera unit and a residential door station. The diagram specifies cable types (e.g., AED, AEO) and connection points (e.g., R1, R2, G+, G-, A1, A2, B1, B2, SL, SC, ST, S1E, S2E, S3E, S4E, S5E), providing a comprehensive guide for system integration.

  • Collegamento elettrico: Connect the AC100V 50/60Hz power supply to the designated terminals.
  • Collegamenti del sensore: The unit supports various sensors including gas/CO sensors (up to 3 units), fire sensors, and water leak sensors. Connect these to the appropriate terminals as shown in the diagram.
  • Dispositivi ausiliari: Connect auxiliary sounders (up to 2 units) and call buttons as needed.
  • Unità fotocamera: If applicable, connect the camera unit for visual monitoring.
  • Residential Door Station: Connect the door station for communication with visitors.

5. Istruzioni per l'uso

The VM-RMT unit features a user-friendly touch panel display for easy operation.

  • Accensione/spegnimento: The unit powers on automatically when connected to the power supply. Use the OFF button to silence alarms or turn off specific functions.
  • Visualizzazione del monitor: The 7-inch TFT LCD touch panel displays security status, alerts, and communication interfaces. Tap icons or menu options to navigate.
  • Comunicazione: Press the TALK button to initiate two-way communication with connected door stations or other intercom units.
  • Avviso di emergenza: In case of an emergency, press the EMERGENCY button to activate the alarm.
  • Indicatori di stato: Observe the Power (green) and Status (red) LEDs for quick visual feedback on the unit's operational state and any active alerts.

6. Manutenzione

Regular maintenance ensures the longevity and reliable operation of your VM-RMT unit.

  • Pulizia: Gently wipe the display and exterior surfaces with a soft, dry cloth. Do not use abrasive cleaners, solvents, or spray directly onto the unit.
  • Ispezione: Periodically check for any visible damage to the unit or wiring. Ensure all connections are secure.
  • Test di funzionalità: Regularly test the alarm functions and communication features to ensure they are working correctly. Refer to the operating instructions for testing procedures.

7. Risoluzione Dei Problemi

If you encounter issues with your VM-RMT unit, refer to the following common problems and solutions.

Problema Possibile causa Soluzione
L'unità non si accende. No power supply; loose power connection. Controllare il collegamento del cavo di alimentazione. Assicurarsi che la presa di corrente sia funzionante.
Nessun audio durante la comunicazione. Microphone or speaker issue; volume too low. Check volume settings on the touch panel. Ensure microphone/speaker are not obstructed.
L'allarme suona inaspettatamente. Sensor triggered; false alarm. Identify the triggered sensor via the display. Investigate the cause. Press OFF button to silence.
Il pannello touch non risponde. Problema temporaneo del software. Disconnect power for 30 seconds, then reconnect to restart the unit.

Se il problema persiste dopo aver provato queste soluzioni, contattare l'assistenza clienti o un tecnico qualificato.

8. Specifiche

Detailed technical specifications for the Aiphone VM-RMT unit.

Caratteristica Specificazione
Alimentazione elettrica AC100V 50 / 60Hz
Consumo energetico Standby: 4.5W, Massimo: 14.5W
Display 7-inch TFT LCD (Touch Panel)
Conteggio pixel Circa. 1.15 milioni di pixel
Peso Circa 1.0 kg
Dimensioni del prodotto (LxWxH) Dimensioni: 26 x 18 x 3.4 cm
Temperatura di esercizio da 0°C a 40°C
Tipo di montaggio Montaggio a parete
Compatible Box JIS2 Standard Switch Box + Separator
Materiale Flame Retardant PC + ABS Resin
Colore Bianco come la neve
Componenti inclusi Unità principale
Metodo di comunicazione Simultaneous Call Method
Fire Alarm Response Japan Fire Protection Association Certified Product
Pressione sonora 70dB or more (1m in front, excluding voice)
Codice JAN 4968249513001

9. Garanzia e supporto

For warranty information, technical support, or service inquiries, please refer to the documentation included with your purchase or visit the official Aiphone websito. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.

Informazioni sui contatti: Si prega di fare riferimento alle istruzioni ufficiali del produttore website or your local distributor for the most up-to-date contact details for support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.