Reznor UDXC-150

Manuale di istruzioni per il riscaldatore a gas naturale Reznor UDXC-150 da 150,000 BTU

Modello: UDXC-150 | Marca: Reznor

1. Introduzione e oltreview

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Reznor UDXC-150 natural gas unit heater. The UDXC-150 is a 150,000 BTU commercial-grade forced air heater designed for various indoor spaces such as garages, workshops, and warehouses. It features an 83% thermal efficiency rating and is built for durability and quiet operation.

2. Informazioni sulla sicurezza

AVVERTIMENTO: L'installazione, la regolazione, l'alterazione, l'assistenza o la manutenzione non corrette possono causare danni alla proprietà, lesioni o morte. Leggere attentamente le istruzioni di installazione, funzionamento e manutenzione prima di installare o riparare questa apparecchiatura.

Precauzioni generali di sicurezza:

  • L'installazione e la manutenzione devono essere eseguite da un installatore qualificato, da un'agenzia di assistenza o da un fornitore di gas.
  • Ensure adequate ventilation is provided as per local codes and manufacturer instructions.
  • Maintain proper clearances from combustible materials as specified in the installation guide.
  • Non conservare o utilizzare benzina o altri vapori e liquidi infiammabili nelle vicinanze di questo o di altri apparecchi.
  • Never obstruct the air intake or exhaust vents.
  • Ispezionare regolarmente l'unità per verificare eventuali segni di danni o malfunzionamenti.

3. Caratteristiche del prodotto

The Reznor UDXC-150 unit heater incorporates advanced technology for reliable and efficient heating:

  • Elevata efficienza termica: Achieves an 83% AFUE (Annual Fuel Utilization Efficiency) rating.
  • Scambiatore di calore durevole: Features a TCORE2 titanium-stabilized aluminized steel heat exchanger for extended lifespan.
  • Accensione avanzata: Equipped with multi-try direct spark ignition with time lockout.
  • Funzionamento silenzioso: Designed for low noise with vibration-isolated fan and venter motors.
  • Display diagnostico: Includes a 7-segment display board for simple troubleshooting and a status-indicating LED light.
  • Montaggio flessibile: Offers 2- and 4-point suspension options for ceiling or wall mounting (mounting hardware sold separately).
  • Facile manutenzione: External gas connection for simplified service access.
  • Certificato di sicurezza: ETL Approved.
  • Heating Flexibility: Single-burner design with two BTU outputs for varying temperature needs.
Reznor UDXC-150 Unit Heater with standard features listed: 83% AFUE Efficiency, Multi-Try Direct Spark Ignition, TCORE2 Titanium-Stabilized Aluminized Steel Heat Exchanger, Low Noise Operation.

This image displays the Reznor UDXC-150 unit heater and highlights its key standard features, including 83% AFUE efficiency, multi-try direct spark ignition with time lockout, a TCORE2 titanium-stabilized aluminized steel heat exchanger, and low noise operation due to vibration-isolated fan and venter motors.

Reznor UDXC-150 Unit Heater with additional standard features: Status-Indicating LED Light, 7-Segment Display Board, 2- and 4-Point Suspension Options, External Gas Connection, ETL Approved.

This image shows the Reznor UDXC-150 unit heater and details further standard features such as a status-indicating LED light, a 7-segment display board for troubleshooting, options for 2- and 4-point suspension, an external gas connection for ease of maintenance, and ETL approval.

4. Contenuto della confezione

Your Reznor UDXC-150 unit heater package includes the following components:

  • Reznor UDXC-150 Natural Gas Unit Heater
  • Vertical Category 1 Double Wall B-Vent Kit (for venting out of a roof)

Vertical B-Vent Kit Components:

  • 1x Reznor CCI Vent Cap
  • 1x Draft Hood Connector
  • 2x 12" Length Straight Pipe (5" diameter)
  • 2x 24" Length Straight Pipe (5" diameter)
  • 2x 60° Adjustable Elbow (5" diameter)
  • 1x 90° Adjustable Elbow (5" diameter)
  • 1x Roof Flashing (up to 5/12 Pitch)
  • 1x 5" Diameter Storm Collar
Components of a 5-inch diameter double wall B-vent kit for vertical Category I venting, including vent cap, draft hood connector, straight pipes, adjustable elbows, roof flashing, and storm collar.

This image displays the various components included in a 5-inch diameter double wall B-vent kit for vertical Category I venting. The kit includes a Reznor CCI Vent Cap, a Draft Hood Connector, 12-inch and 24-inch straight pipes, 60-degree and 90-degree adjustable elbows, roof flashing, and a storm collar.

5. Configurazione e installazione

Installation of the Reznor UDXC-150 unit heater requires adherence to all local codes and regulations, as well as the detailed instructions provided in the full installation manual. It is strongly recommended that installation be performed by a qualified and licensed professional.

Considerazioni chiave sull'installazione:

  • Montaggio: The unit can be ceiling-mounted or wall-mounted using appropriate suspension points. Mounting hardware is sold separately. Ensure the mounting structure can safely support the weight of the unit.
  • Sfiato: This model includes a vertical Category 1 double wall B-vent kit. Proper venting is crucial for safety and efficiency. Follow all instructions for vent pipe assembly and roof flashing.
  • Collegamento gas: Connect the unit to a natural gas supply line. All gas connections must be leak-tested by a qualified professional. The external gas connection is designed for ease of access.
  • Collegamento elettrico: The unit requires a 24V electrical connection. Ensure all wiring is done according to electrical codes and the manufacturer's specifications. The unit includes an external terminal strip for 24V wiring and a built-in enhanced disconnect switch.
  • Distanze: Maintain specified clearances from combustible materials around the heater and vent system.
Reznor UDXC-150 Unit Heater mounted on a ceiling in a workshop, with text describing compact and durable heating, suitable for commercial spaces and ceiling/wall mounting.

This image shows the Reznor UDXC-150 unit heater installed on a ceiling, emphasizing its compact and durable design. It highlights its suitability for larger commercial garages, warehouses, and industrial workspaces, and its capability for ceiling or wall mounting with multiple venting options.

Reznor UDXC-150 Unit Heater showing simplified installation and advanced features like removable front face, hinged access door, threaded-nut retainers, integrated circuit board, disconnect switch, LED, and external terminal strip.

This image highlights the simplified installation and advanced features of the Reznor UDXC-150 unit heater. It points out the updated cabinet structure with a removable front face, a hinged access door panel with a quarter-turn latch, threaded-nut retainers for ceiling or wall mounting, an enhanced integrated circuit board with a 7-segment display, a built-in enhanced disconnect switch, a status-indicating LED, and an external terminal strip for 24V wiring.

6. Istruzioni per l'uso

Once properly installed and connected, the Reznor UDXC-150 unit heater is designed for straightforward operation, typically controlled by an external thermostat (not included).

Funzionamento di base:

  • Accensione: Ensure the main power supply to the unit is switched on.
  • Controllo del termostato: Set your external thermostat to the desired temperature. The heater will automatically cycle on and off to maintain the set temperature.
  • Potenza termica: The single-burner design offers two BTU outputs. The unit will automatically adjust between high fire for colder conditions and low fire for milder temperatures to ensure efficient heating.
  • Circolazione dell'aria: The low static pressure axial fan provides effective air circulation, distributing heat evenly throughout the space.
  • Indicatore di stato: Observe the status-indicating LED and the 7-segment display board for operational status and any diagnostic codes.

For detailed startup procedures and advanced settings, refer to the complete operating manual.

7. Manutenzione

Regular maintenance ensures the longevity and efficient operation of your Reznor UDXC-150 unit heater. All maintenance should be performed by a qualified service technician.

Programma di manutenzione consigliato:

  • Ispezione annuale: Have a qualified technician inspect the heat exchanger, burner, ignition system, fan motor, and all gas and electrical connections annually.
  • Pulizia: Ensure the fan blades and heat exchanger fins are free from dust and debris to maintain optimal airflow and efficiency.
  • Controllo del sistema di ventilazione: Inspect the entire vent system for any blockages, leaks, or corrosion.
  • Dispositivi di sicurezza: Verify the proper operation of all safety controls and limit switches.

Scollegare sempre l'alimentazione dall'unità prima di effettuare qualsiasi operazione di manutenzione o pulizia.

8. Risoluzione Dei Problemi

The Reznor UDXC-150 is equipped with diagnostic features to assist in identifying operational issues. Refer to the full service manual for detailed troubleshooting steps.

Common Indicators and Actions:

  • Nessun riscaldamento/Unità non avviata: Check power supply, gas supply, and thermostat settings. Consult the 7-segment display for error codes.
  • Rumori insoliti: Could indicate fan imbalance, motor issues, or debris. Disconnect power and inspect. If persistent, contact a technician.
  • LED di stato: The status-indicating LED provides a quick visual cue of the unit's operational state. Refer to the manual for specific flash codes.
  • Display a 7 segmenti: This display will show diagnostic codes that pinpoint specific issues. Note the code and consult the troubleshooting section of the detailed manual.

If you are unable to resolve an issue, contact a qualified HVAC service technician.

9. Specifiche

CaratteristicaDettaglio
MarcaReznor (Distributed by 1HVAC)
Numero di modelloUDXC-150
Classificazione BTUPotenza nominale: 150,000 BTU
Efficienza termica83% AFUE
Tipo di carburanteGas naturale
Metodo di riscaldamentoAria forzata
Fattore di formaMounted (Ceiling/Wall)
Uso interno/esternoAl chiuso
Dimensioni del prodotto (P x L x A)48.44" x 38.19" x 20.13"
Numero di velocità2
Vent Kit IncludedVertical Category 1 Double Wall B-Vent Kit (5-inch diameter)
Reznor UDXC-150 Unit Heater with dimensions: 20 1/8 inches height, 38 3/16 inches width, 48 7/16 inches depth, and 150,000 BTU rating.

This image illustrates the physical dimensions of the 150,000 BTU Reznor UDXC-150 unit heater, showing its height of 20 1/8 inches, width of 38 3/16 inches, and depth of 48 7/16 inches.

10. Garanzia e supporto

For specific warranty information regarding your Reznor UDXC-150 unit heater, please refer to the documentation included with your purchase or contact the seller directly. Warranty terms typically cover manufacturing defects and may vary.

For technical support, service inquiries, or to purchase replacement parts, please contact 1HVAC, the distributor of this product. You can visit the 1HVAC Store per ulteriori informazioni.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.