1. Introduzione
This manual provides essential information for the safe and efficient operation of your EVTSCAN F2100B 2-Axes Linkage CNC Control System. This system is designed for use with CNC flame and plasma cutting machine equipment, offering precise control and a user-friendly interface.
Key features include quick connection terminals for easy setup, multi-language support (Chinese, English, Spanish, Portuguese, French, and more), a 7-inch HD LCD display for clear observation, and a compact keyboard design for comprehensive manual input.
2. Informazioni sulla sicurezza
AVVERTIMENTO: Failure to follow these safety instructions may result in serious injury, death, or damage to the equipment.
- Keep hands and feet clear of moving machine parts. Access to moving parts may be possible through the front panel.
- When operating the machine, avoid wearing loose clothing or wire ropes that could become entangled.
- This equipment must only be operated by trained and authorized personnel.
- Disassembly of the unit by unauthorized technical personnel is strictly prohibited.
- Do not spill acidic, alkaline, corrosive, or other harmful substances onto the control system.
- Electric shock can be fatal. Installation must adhere strictly to the steps and requirements outlined in this manual and the package.
- Never touch wires or cables when the power is on.
3. Contenuto della confezione
Verificare che tutti gli elementi elencati di seguito siano presenti nella confezione:
- 1 x CNC Control System (F2100B)
- 3 x Plugs (total 15 pieces)
- 1 x Terminals set

Figure 3.1: Included plugs, terminals, and mounting hardware.
4. Prodotto finitoview
The EVTSCAN F2100B is a robust 2-axes linkage CNC control system featuring a compact keyboard and a high-definition display, designed for industrial cutting applications.

Figura 4.1: Fronte view of the EVTSCAN F2100B CNC Control System, highlighting the keyboard and display.

Figure 4.2: The 7-inch HD display provides clear visual feedback for the 2-axes linkage CNC control system.

Figura 4.3: dettagliata view of the control panel, showing function keys, navigation buttons, and alphanumeric input area.
5. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Tipo di articolo | CNC Control System |
| Materiale del prodotto | Acciaio inossidabile |
| Modello del prodotto | Codice articolo: F2100B |
| Number of Control Axes | 2 Axes Linkage |
| Precisione del controllo | ±0.001 mm |
| Coordinate Range | ± 99999.99mm |
| Maximum Pulse Frequency | 200KHz |
| Massima velocità operativa | 15 meter/min |
| Maximum Program Lines | 80000 linee |
| Maximum Single Program | 4M |
| Time Class Resolution | 10 millisecondo |
| System Working Power | DC +24V power input, power greater than 80W |
| Display | 7in 800 x 480 HD 16 million color high brightness LCD display |
| Interfaccia USB | 1.1 front interface, supports at least 16GB U disk |
| Frequenza della CPU | 400 MHz |
| User Available Program Space | 256M electronic hard disk |
| Dimensioni del pacco | 14.96 x 10.63 x 5.12 pollici |
| Peso dell'articolo | 4.62 libbre |
| Produttore | EVTSCAN |
| Numero modello articolo | EVTSCANok1zmbc5gs |
6. Configurazione e installazione
Proper installation is crucial for the safe and correct functioning of the CNC control system. Always refer to the detailed wiring diagrams provided with your specific machine and this manual.
6.1 Collegamento di alimentazione
- The system requires a DC +24V power input. Ensure the power supply is greater than 80W.
- Connect the power supply to the DC 24V terminal on the rear panel (CN6). Observe polarity (+ and -).
6.2 Collegamenti di cablaggio
Connect all necessary input, output, and motor cables according to the provided wiring instructions. Use the quick connection terminals and plugs for secure connections.
- CN1 (Input): Connect input signals from your machine.
- CN2 (Output): Connect output signals to your machine.
- CN3 (Motor1): Connect to the first motor.
- CN4 (Motor2): Connect to the second motor.
- CN5 (RS232): Porta di comunicazione seriale.
- CN8 (CAN): CAN bus communication port.
- CN6/CN7: Additional signal and motor limit connections.

Figure 6.1: Rear panel connections of the F2100B control system, including power, input, output, motor, and communication ports.
6.3 Messa a terra
Ensure proper grounding of the control system to prevent electrical hazards and ensure stable operation. Refer to your machine's grounding requirements.
7. Istruzioni per l'uso
The F2100B control system is designed for intuitive operation through its integrated keyboard and 7-inch HD display. Specific operational procedures will depend on the cutting machine it is integrated with and the software used.
7.1 Accensione/Spegnimento
- To power on, ensure all connections are secure and then apply DC +24V power. The system will boot up and display the main interface.
- To power off, follow the shutdown procedure within the system's software interface if available, then disconnect the power supply.
7.2 Navigazione e input di base
- Use the alphanumeric keys for data entry and program editing.
- Function keys (F1-F8) provide quick access to common operations such as Ignition, Preheat, Arc, Heighten, Cut Oxy, and I/O off.
- Navigation keys (arrows, HOME, END, PgUp, PgDn) allow movement within menus and programs.
- The 'START' button initiates operations, and the 'STOP' button halts them.
7.3 Selezione della lingua
The system supports multiple languages. Refer to the system settings menu on the display to select your preferred language (e.g., Chinese, English, Spanish, Portuguese, French).
Connettività USB 7.4
A front USB 1.1 interface is provided for data transfer, supporting U disks of at least 16GB. This allows for easy loading of cutting programs and system updates.
8. Manutenzione
Regular maintenance ensures the longevity and reliable performance of your CNC control system.
- Pulizia: Keep the display and keyboard clean and free from dust, debris, and corrosive substances. Use a soft, dry cloth for cleaning. Avoid harsh chemicals.
- Connessioni: Periodically check all cable connections for tightness and signs of wear or damage. Ensure plugs and terminals are securely seated.
- Ambiente: Operate the system in a clean, dry environment within the specified temperature and humidity ranges. Protect it from excessive vibrations and impacts.
- Aggiornamenti software: Check for any available software or firmware updates from the manufacturer to ensure optimal performance and access to new features.
9. Risoluzione Dei Problemi
Questa sezione fornisce indicazioni generali per i problemi più comuni. Per problemi più complessi, contattare l'assistenza tecnica.
9.1 Il sistema non si accende
- Verify that the DC +24V power supply is connected correctly and is providing sufficient power (greater than 80W).
- Check all power cables and connections for damage or loose contacts.
- Assicurarsi che la fonte di alimentazione sia attiva.
9.2 Display non funzionante
- Confirm the system is powered on.
- Check for any display cable connections if applicable (internal, not user-serviceable).
- If the system powers on but the display remains blank, contact technical support.
9.3 Input/Output Malfunction
- Inspect the specific input/output cables connected to CN1 and CN2 for damage or incorrect wiring.
- Verify the settings within the control system's software for correct I/O configuration.
9.4 Motor Control Issues
- Check motor connections to CN3 and CN4.
- Ensure motor drivers are correctly configured and receiving signals from the control system.