Introduzione
Thank you for choosing the Aideepen USB-C Power Meter and Protocol Tester. This device is designed for precise measurement and monitoring of USB-C power delivery, supporting various fast charging protocols. Its robust construction and intuitive display make it an essential tool for tech enthusiasts and professionals.
This manual provides detailed instructions on how to set up, operate, and maintain your device, ensuring optimal performance and longevity.
Prodotto finitoview
The Aideepen USB-C Power Meter features a 1.14-inch HD IPS display housed in a durable CNC metal case, offering dustproof and drop-resistant properties. It provides real-time data for voltage, current, power, and supports various fast charging protocols.

Image: The USB-C Power Meter's display showing real-time voltage, current, and power readings, along with protocol information.
Caratteristiche principali:
- High-Definition IPS Display: 1.14-inch screen for clear, real-time data visualization.
- Costruzione durevole: CNC metal casing provides dustproof and drop-resistant protection.
- One-Touch Page Switching: Easily navigate between three multi-functional display pages.
- Professional Measurement: Includes curve measurement, ripple measurement, and comprehensive protocol testing.
- Ampio supporto di protocollo: Compatible with PD2.0/3.0, PPS, QC2.0/3.0, FCP, SCP, AFC, PE, DASH, VOOC, SuperVooc.
- Stabile e sicuro: Utilizes reliable Type-C voltage and current detection technology for secure monitoring.
- Rotazione automatica dello schermo: Built-in gravity sensor for convenient vieworientamento.
Layout del dispositivo:

Image: Diagram illustrating the device's buttons and ports. The device features a USB-C input and output, along with control buttons on the side.
- Tasto indietro: Returns to the previous menu or main page.
- Pulsante OK: Conferma le selezioni o accede ai sottomenu.
- Pulsanti sinistra/destra: Navigates between display pages or selects options within menus.
- Interruttore OFF/ON: Interruttore di alimentazione per il dispositivo.
Impostare
The Aideepen USB-C Power Meter is designed for plug-and-play operation. No complex setup is required.
- Accensione: Ensure the OFF/ON switch on the side of the device is in the 'ON' position.
- Connetti alla fonte di alimentazione: Plug the USB-C input of the tester into your power adapter or power bank.
- Connetti dispositivo: Plug your USB-C device (e.g., smartphone, tablet, laptop) into the USB-C output of the tester.
- Inizia il monitoraggio: The device will automatically power on and begin displaying real-time voltage, current, and power data.
Istruzioni per l'uso
The tester offers multiple display modes and functions accessible via its side buttons.
Switching Display Pages:
The device has three main display pages. Use the Left/Right buttons per scorrerli:
- Page 1: Real-time Data Display
Shows current direction, voltage, current, power, charging protocol, handshake position, and data line voltage (D+, D-, CC1, CC2). - Page 2: Capacity Statistics & Max Values
Visualizza voltage, current, power, charging protocol, capacity statistics (automatically saved when powered off), maximum voltage, current, power, and MCU chip real-time temperature. - Page 3: Curve Display
Presents voltage and current as curves on a unit grid, sampling time, current direction, real-time curve plotting, voltage, corrente e potenza.

Image: The three main display pages of the USB-C Power Meter, showing real-time data, accumulated statistics, and a voltage/current curve graph.
Cambio lingua:
To switch the display language (Chinese/English):

Image: Visual guide for navigating the menu to change the display language from Chinese to English.
- Dal display principale, premere il tasto Tasto indietro to enter the 'Menu' screen.
- Utilizzare il Left/Right buttons to select '3 Setting' and press the Pulsante OK per accedere all'interfaccia delle impostazioni.
- Select 'Language' using the Left/Right buttons e premere OK. Utilizzare il Left/Right buttons to switch between languages. After successful switching, press OK di nuovo per confermare.
- Una volta completate le impostazioni, premere il tasto Tasto indietro to exit the settings interface and return to normal operation.
Protocol Testing:
The device supports various protocol tests, including Auto-Test and PD Single Cheat. Navigate to the 'Protocol' menu option to access these features.

Image: The protocol test menu, showing options like 'Auto-Test' and 'PD Single Cheat' for advanced power delivery analysis.
For detailed protocol testing, refer to the on-screen prompts and use the OK E Left/Right buttons to navigate and select options. The device will display supported protocols (green) and unsupported protocols (red).
Rilevamento della corrente bidirezionale:
The tester supports bidirectional current detection, allowing you to monitor power flow regardless of the connection orientation.

Image: The device demonstrating its ability to detect current flow in both directions, useful for various charging setups.
Manutenzione
- Pulizia: Per pulire il dispositivo, utilizzare un panno morbido e asciutto. Evitare l'uso di detergenti abrasivi o solventi.
- Magazzinaggio: Conservare il dispositivo in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.
- Gestione: While the device is drop-resistant, avoid unnecessary impacts to prevent damage to internal components or the display.
- Aggiornamenti del firmware: Check the official Aideepen websito per eventuali aggiornamenti firmware disponibili per garantire prestazioni e compatibilità ottimali.
Risoluzione dei problemi
- Nessun display/alimentazione:
Ensure the OFF/ON switch is in the 'ON' position. Verify that the power source is active and providing power to the tester. Try a different USB-C cable or power source. - Letture errate:
Ensure all connections are secure. Some cables or devices may not fully support certain fast charging protocols, leading to lower than expected readings. Test with known good cables and devices. - Display Frozen/Unresponsive:
Try turning the device off and then on again using the OFF/ON switch. If the issue persists, disconnect all power, wait a few seconds, and reconnect. - Problema linguistico:
Follow the 'Language Switching' instructions in the Operating section to set your preferred language.
Specifiche
| Caratteristica | Specificazione |
|---|---|
| Marca | aiutante |
| Numero di modello | KBAI0058-AAB |
| Ingresso/Uscita Voltage Gamma | DC 4-30V |
| Intervallo attuale | 0-12A |
| Intervallo di potenza | 0-360 W |
| Display | 1.14-inch HD IPS Color Screen |
| Protocolli supportati | PD2.0/3.0, PPS, QC2.0/3.0, FCP, SCP, AFC, PE, DASH, VOOC, SuperVooc |
| Dimensioni (circa) | 54.96 mm x 24.45 mm x 11.15 mm (2.16 pollici x 0.96 pollici x 0.44 pollici) |
| Colore | Nero |
| Origine | Cina |

Image: Detailed dimensions of the Aideepen USB-C Power Meter.
Garanzia e supporto
This Aideepen product comes with a Garanzia di 180 giorni dalla data di acquisto, a copertura dei difetti di fabbricazione. Si prega di conservare la prova d'acquisto per eventuali reclami in garanzia.
For technical support, troubleshooting assistance, or warranty inquiries, please contact Aideepen customer service through the retailer's platform or visit the official Aideepen websito per le informazioni di contatto.
We are committed to providing high-quality products and support to our customers.