1. Introduzione
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new Faber 60 cm 1200 m³/hr Autoclean Curved Chimney. Please read all instructions carefully before using the appliance and retain this manual for future reference.

Image 1.1: Faber 60 cm Autoclean Curved Chimney, front view.
2. Informazioni sulla sicurezza
Seguire sempre le precauzioni di sicurezza di base quando si utilizzano apparecchi elettrici per ridurre il rischio di incendi, scosse elettriche e lesioni. Questo apparecchio è destinato esclusivamente all'uso domestico.
- Assicurarsi che l'alimentazione corrisponda al voltage specificato sull'apparecchio.
- Do not operate the chimney with a damaged cord or plug.
- Tenere i bambini lontani dall'apparecchio durante il funzionamento.
- Non flambare sotto la cappa aspirante.
- Clean the oil collector regularly to prevent grease buildup and fire hazards.
- Ensure adequate ventilation in the room when the chimney is used simultaneously with gas or other fuel-burning appliances.
3. Caratteristiche del prodotto
Your Faber Autoclean Curved Chimney is equipped with advanced features for an optimal kitchen environment:
- Tipo: Black Curved Glass, Wall Mounted.
- Tipo di filtro: Filterless design for hassle-free maintenance.
- Potenza di aspirazione: 1200 m³/hr for effective smoke and odor removal.
- Tipo di controllo: Touch Control, Gesture Control, and Motion Sensor for easy operation.
- Livelli di velocità: 3 adjustable speed settings.
- Livello di rumore: 59dB for quiet operation.
- Caratteristiche speciali: Autoclean function, Built-in Oil Collector, and 1 LED Lamp.

Image 3.1: Key features including silent operation, gesture control, and premium black glass finish.

Image 3.2: The chimney is designed for low noise operation, ensuring a quiet kitchen environment.
4. Configurazione e installazione
Proper installation is crucial for the performance and safety of your chimney. It is recommended to have the chimney installed by a qualified technician.
4.1 Controlli pre-installazione
- Dimensioni del mobile: Measure the clear width between your kitchen cabinets. Common chimney widths are 60 cm, 75 cm, and 90 cm. This model is 60 cm.
- Distanza in altezza: Measure the height from your gas stove to the desired chimney base position. For T-shape/Curved models, a minimum clearance of 28-30 inches (71-76 cm) is typically recommended.
- Alimentazione elettrica: Ensure a suitable electrical outlet (230 Volts) is available near the installation area.

Image 4.1: Chimney dimensions and recommended distance from the gas stove to the chimney base.
4.2 Tipo di installazione
This chimney is suitable for ducted installation. For ductless use, a charcoal filter (to be purchased separately) is required. Contact customer support for more information on ductless conversion.

Image 4.2: Illustration of ducted and ductless installation options.
4.3 Guida all'installazione Video
Watch this video for a visual guide on important measurements and installation considerations for your chimney.
Video 4.3: Chimney installation guide covering width and height measurements.
5. Istruzioni per l'uso
Your Faber chimney offers intuitive control options for a seamless cooking experience.
5.1 Pannello di controllo
The chimney features a touch control panel, gesture control, and motion sensor for easy operation. The control panel typically includes buttons for power, speed adjustment (3 levels), light, and autoclean function.

Image 5.1: Close-up of the touch control panel.
5.2 Controllo dei gesti
To activate or adjust settings using gesture control, simply wave your hand in front of the motion sensor. Refer to the specific gesture patterns in the quick start guide for detailed instructions.

Image 5.2: Demonstrating gesture control for the chimney.
5.3 Regolazione della velocità
Select from 3 speed levels to match your cooking needs. Use lower speeds for light cooking and higher speeds for heavy frying or grilling to ensure maximum smoke extraction.
6. Manutenzione
Regular maintenance ensures the longevity and optimal performance of your Faber chimney.
6.1 Funzione di autopulizia
The autoclean feature simplifies cleaning by collecting oil in a detachable tray. Activate the autoclean function as per the instructions in the quick start guide. This process helps maintain the chimney's efficiency without manual scrubbing.

Image 6.1: Autoclean feature with visible oil collector and LED light.
6.2 Oil Collector Cleaning
The built-in oil collector should be emptied and cleaned regularly. To remove, gently slide out the oil tray. Wash it with warm soapy water, rinse thoroughly, and ensure it is completely dry before reinserting.
6.3 Filterless Technology
This chimney features filterless technology, eliminating the need for traditional filter cleaning. The powerful suction and autoclean function manage grease and smoke effectively.

Image 6.2: Illustration of the filterless design.

Image 6.3: Powerful suction without the need for messy filter cleaning.
7. Risoluzione Dei Problemi
If you encounter any issues with your chimney, refer to the following common troubleshooting steps:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il camino non si accende | No power supply, loose connection, power outage. | Check power plug, circuit breaker, and main power supply. |
| Bassa potenza di aspirazione | Oil collector full, ducting obstruction, incorrect speed setting. | Empty and clean oil collector. Check ducting for blockages. Increase speed setting. |
| Rumore insolito durante il funzionamento | Loose parts, motor issue, foreign object in fan. | Turn off and inspect for loose components. Contact service if noise persists. |
| Le luci non funzionano | LED lamp failure, loose wiring. | Check connections. If LED is faulty, contact service for replacement. |
If the issue persists after attempting these steps, please contact Faber customer support.
8. Specifiche
| Attributo | Valore |
|---|---|
| Marca | Fabbro |
| Numero di modello | 330.0738.738 |
| Dimensioni del prodotto (P x L x A) | 41D x 60W x 43H centimetri |
| Colore | Nero |
| Capacità del flusso d'aria | 1200 metri cubi all'ora |
| Livello di rumore | 59 decibel |
| Tipo di montaggio | Montaggio a parete |
| Tipo di controlli | Tocco, gesto |
| Voltage | 230 Volt |
| Numero Di Velocità | 3 |
| Sorgente luminosa | GUIDATO |
| Tipo di filtro | Senza filtro |
| Tipo di ventilazione | canalizzato |
| Peso dell'articolo | 11400 grammi |
| Paese di origine | India |
9. Garanzia e supporto
Your Faber chimney comes with comprehensive warranty coverage and dedicated support.
- Garanzia del prodotto: 2 Years Comprehensive Warranty on the entire product.
- Garanzia del motore: 8 anni di garanzia sul motore.
For warranty claims, service requests, or technical assistance, please contact Faber customer support at 1800-209-3484.

Image 9.1: Warranty information for the product and motor.
9.1 Opzioni di garanzia estesa
You may have options to extend your warranty coverage. Please refer to your purchase documentation or contact Faber for details on available extended warranty plans.
- 3 Years Faber Protect+ Extended Warranty: Available from Faber.
- 1 or 2 Years Total Protection: Available from Acko.
10. Prodotto finitoview Video
Guarda questo video per una panoramica completaview of the Faber Autoclean Curved Chimney's features and benefits.
Video 10.1: Detailed product overview of the Faber Autoclean Curved Chimney.