Introduzione
Thank you for choosing the Elitech TM-2TH Digital Thermometer Hygrometer. This device is designed for precise monitoring of temperature and humidity in various environments, including refrigerators, freezers, wine cabinets, and more. Please read this manual carefully before use to ensure proper operation and to maximize the lifespan of your device.
Caratteristiche del prodotto

The Elitech TM-2TH offers precision monitoring with a temperature range of -10°C to 50°C and a humidity range of 10% to 95% RH. It features ultra-long battery life, flexible installation options, and a °C/°F toggle function.

This device provides high accuracy with ±1°C temperature accuracy and ±5% RH precision (within 30%~85% RH range), ensuring reliable readings for critical environments.

The TM-2TH automatically records and displays maximum and minimum temperature and humidity values, allowing users to track environmental fluctuations over time.

Designed for versatility, the thermometer hygrometer can be installed in three ways: hanging via its integrated hook, standing on a flat surface, or magnetically attached to metal surfaces.

The TM-2TH is suitable for a wide range of applications, including monitoring conditions in wine cabinets, medicine cabinets, refrigerators, camping boxes, and baby's fridges.
Specifiche
| Modello | TM-2TH |
| Intervallo di temperatura | da -10°C a 50°C (da 14°F a 122°F) |
| Precisione della temperatura | ±1°C (±1.8°F) |
| Umidità ambiente | 10% al 95% di umidità relativa |
| Precisione dell'umidità | ±5% RH (within 30%~85% RH) |
| Tipo di batteria | 1 x CR2032 (incluso) |
| Riferimento del prodotto | TM-2TH-2Pack |
| Dimensioni della confezione (circa) | Dimensioni: 15.4 x 9.5 x 6.5 cm |
| Peso del pacco (circa) | 90 grammi |
| Paese di origine | Cina |
Impostare
1. Installazione della batteria
- Individuare il coperchio del vano batteria sul retro del dispositivo.
- Aprire il coperchio facendolo scorrere o sollevandolo delicatamente.
- Insert one CR2032 battery, ensuring the positive (+) side faces upwards.
- Replace the battery compartment cover securely. The device should power on automatically and display current temperature and humidity.
2. Posizionamento
The TM-2TH offers multiple placement options:
- In piedi: Use the integrated kickstand to place the device on any flat surface.
- Sospeso: Utilize the built-in hook to hang the device from a rack or hook.
- Magnetico: Attach the device to any metallic surface, such as a refrigerator door, using its magnetic backing.
Choose a location that provides accurate readings for the area you wish to monitor, avoiding direct sunlight or heat sources.
Istruzioni per l'uso
1. Reading Display
Upon activation, the device will display the current temperature and relative humidity. The temperature is typically shown in degrees Celsius (°C) or Fahrenheit (°F), and humidity as a percentage(%).
2. Commutazione delle unità di temperatura (°C/°F)
Locate the °C/°F button, usually on the back or side of the device. Press this button to toggle between Celsius and Fahrenheit temperature units.
3. ViewRegistrazione dei record MAX/MIN
Il dispositivo registra automaticamente i valori di temperatura e umidità più alti (MAX) e più bassi (MIN) dall'ultimo reset. view questi record:
- Premere il tasto Massimo/minimo premere una volta il pulsante per visualizzare i valori massimi registrati.
- Premere il tasto Massimo/minimo nuovamente il pulsante per visualizzare i valori minimi registrati.
- Press it a third time to return to the current temperature and humidity display.
4. Resetting MAX/MIN Records
To clear the recorded MAX/MIN values and start a new recording cycle:
- Mentre viewing the MAX or MIN records, press and hold the Massimo/minimo pulsante per circa 3 secondi.
- The display will flash, indicating that the records have been reset to the current temperature and humidity.
Manutenzione
1. Sostituzione della batteria
When the display becomes dim or the device stops functioning, it is time to replace the CR2032 battery. Follow the battery installation steps in the "Setup" section to replace the battery.
2. Pulizia
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water. Ensure the sensor openings are free from dust and debris for accurate readings.
3. Conservazione
If the device will not be used for an extended period, remove the battery to prevent leakage and store it in a cool, dry place.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Nessun display o display poco luminoso | La batteria è scarica o non è installata correttamente. | Sostituire la batteria CR2032 o assicurarsi che sia installata con la polarità corretta. |
| Letture imprecise | Sensor blocked or device placed near heat/cold source. | Ensure sensor openings are clear. Relocate the device to a more representative area. Allow time for readings to stabilize. |
| MAX/MIN values not resetting | Pulsante non tenuto abbastanza a lungo. | Press and hold the MAX/MIN button for at least 3 seconds until the display flashes. |
Garanzia e supporto
Elitech provides a standard warranty for its products. For specific warranty terms, technical support, or service inquiries, please refer to the warranty card included with your purchase or visit the official Elitech websito. Conservare la prova d'acquisto per eventuali reclami in garanzia.