SEBSON IR_OUT_IA

SEBSON Outdoor Motion Detector IR_OUT_IA User Manual

Model: IR_OUT_IA | Brand: SEBSON

1. Introduzione

Thank you for choosing the SEBSON Outdoor Motion Detector. This device is designed for reliable outdoor use, featuring an IP65 rating for weather resistance and a 240° infrared sensor. It is programmable for ignition duration, ambient brightness, and detection range, making it suitable for various lighting applications with both incandescent and LED bulbs. This manual provides essential information for safe installation, operation, and maintenance of your motion detector.

SEBSON Outdoor Motion Detector, front view

Immagine 1: anteriore view of the SEBSON Outdoor Motion Detector, showcasing its compact design and sensor lens.

2. Istruzioni di sicurezza

Si prega di leggere attentamente le presenti istruzioni di sicurezza prima dell'installazione e dell'uso. La mancata osservanza di queste istruzioni può causare scosse elettriche, incendi o altri pericoli.

  • Installazione elettrica: L'installazione deve essere effettuata da un elettricista qualificato, nel rispetto delle normative locali in materia di cablaggio.
  • Disconnessione dell'alimentazione: Always disconnect the main power supply before performing any installation, maintenance, or repair work.
  • Voltage: Garantire la fornitura voltage matches the detector's specified voltage (230 Volt).
  • Uso esterno: The device is IP65 rated for outdoor use, protecting against dust and water jets. Ensure all connections are properly sealed.
  • Montaggio: Mount the detector securely on a stable wall surface.
  • Bambini: Tenere i materiali di imballaggio e le piccole parti fuori dalla portata dei bambini.

3. Prodotto finitoview

The SEBSON Outdoor Motion Detector features three adjustable dials for precise control over its operation:

  • LUSSO: Adjusts the ambient brightness threshold (3-2000 LUX) at which the detector activates.
  • SENSO: Controls the detection range (8-14 meters).
  • TEMPO: Sets the duration (10 seconds to 15 minutes) for which the connected light remains on after motion is detected.
Close-up of the SEBSON motion detector's adjustment dials for LUX, SENS, and TIME settings.

Immagine 2: Primo piano view of the three adjustment dials (LUX, SENS, TIME) located on the underside of the motion detector.

4. Configurazione e installazione

4.1 Montaggio del rilevatore

The motion detector is designed for wall surface mounting. Choose a stable location that provides the desired detection coverage and is within the recommended mounting height.

  1. Disconnect the main power supply before starting installation.
  2. Separate the mounting base from the main unit.
  3. Segnare i punti di foratura sulla parete utilizzando la base di montaggio come modello.
  4. Praticare dei fori e inserire tasselli adeguati (se necessario).
  5. Secure the mounting base to the wall using screws. Ensure the 'UP' arrow on the base points upwards.
Indietro view of the SEBSON motion detector's mounting base with 'UP' arrow and screw holes.

Immagine 3: posteriore view of the mounting base, showing the 'UP' indicator and screw holes for wall attachment.

Diagram showing the dimensions of the mounting plate, 60mm width.

Image 4: Diagram illustrating the width of the mounting plate, which is 60 mm.

4.2 Cablaggio

This motion detector uses a 3-wire connection. Ensure all wiring is done with the power supply disconnected.

  • Connect the Live (L) wire from the power supply to the 'L' terminal on the detector.
  • Connect the Neutral (N) wire from the power supply to the 'N' terminal on the detector.
  • Connect the Switched Live (L') wire from the detector to the Live terminal of your light fixture.
  • Connect the Neutral wire from the power supply to the Neutral terminal of your light fixture.
  • Assicurarsi che tutti i collegamenti siano ben saldi e adeguatamente isolati.

4.3 Considerazioni sul posizionamento

Optimal performance depends on correct placement:

  • Altezza di montaggio: The recommended mounting height is between 1.80 meters and 2.50 meters for optimal detection.
  • Area di rilevamento: The sensor has a 240° detection angle and a range of 8-14 meters. Position it to cover the desired area without unnecessary triggers.
  • Evitare ostacoli: Do not mount the detector near large objects, trees, or walls that could obstruct the detection field.
  • Fattori ambientali: Avoid mounting near direct sunlight, heat sources (e.g., vents, outdoor units), or areas with constant movement (e.g., busy roads) to prevent false triggers.
Diagram illustrating the 240 degree detection angle and up to 14 meter range of the motion detector, with recommended mounting height.

Image 5: Detection area diagram, showing the 240° angle, maximum 14m range, and recommended mounting height of 1.80m to 2.50m.

Lato view dimensions of the SEBSON motion detector, showing 99mm length and 61mm height.

Immagine 6: Lato view dimensions of the motion detector, indicating a length of 99mm and a height of 61mm.

5. Istruzioni per l'uso

After installation, restore power and adjust the settings using the three dials on the underside of the detector (refer to Image 2).

  • LUX (Luminosità ambientale): Turn the dial towards the 'sun' symbol for activation in brighter conditions (up to 2000 LUX) or towards the 'moon' symbol for activation only in darker conditions (down to 3 LUX).
  • TIME (Ignition Duration): Rotate the dial to set how long the light remains on after motion is detected. Settings range from 10 seconds to 15 minutes.
  • SENS (Detection Range): Adjust this dial to control the sensitivity and effective detection distance, from 8 meters to 14 meters. Test different settings to find the optimal range for your environment.

Prova: It is recommended to test the detector's settings during both day and night to ensure it operates as desired. You can set the LUX to maximum (sun symbol) for daytime testing of range and time duration, then adjust it to the desired ambient light level for normal operation.

6. Manutenzione

The SEBSON Outdoor Motion Detector requires minimal maintenance.

  • Pulizia: Periodically wipe the sensor lens and housing with a soft, damp panno per rimuovere polvere e sporco. Non utilizzare detergenti o solventi abrasivi.
  • Ispezione: Regularly check the detector for any signs of damage, loose connections, or wear.
  • Ostruzioni: Ensure no new obstructions (e.g., growing plants, debris) are blocking the sensor's field of view.

7. Risoluzione Dei Problemi

Se riscontri problemi con il tuo rilevatore di movimento, fai riferimento ai seguenti problemi comuni e alle relative soluzioni:

ProblemaPossibile causaSoluzione
La luce non si accende quando viene rilevato un movimento.
  • Impostazione LUX errata (troppo alta).
  • Nessuna alimentazione elettrica.
  • Lampadina/apparecchio difettoso.
  • Sensore ostruito.
  • Regolare l'impostazione LUX verso il simbolo della "luna".
  • Controllare i collegamenti elettrici e l'interruttore automatico.
  • Test light fixture with another power source.
  • Rimuovere eventuali ostruzioni dal sensore.
La luce rimane costantemente accesa.
  • Movimento continuo nell'area di rilevamento.
  • Impostazione TIME troppo lunga.
  • Errore di cablaggio.
  • Reduce SENS setting or reposition detector.
  • Regolare l'impostazione TIME su una durata più breve.
  • Verificare i collegamenti elettrici.
La luce si accende senza alcun movimento apparente.
  • High sensitivity (SENS).
  • Environmental factors (wind, heat, small animals).
  • Sensor picking up distant movement.
  • Ridurre l'impostazione SENS.
  • Reposition detector to avoid heat sources or busy areas.
  • Adjust the angle of the sensor head.
Il raggio di rilevamento è troppo corto/lungo.
  • SENS setting incorrect.
  • Altezza di montaggio non corretta.
  • Adjust SENS setting.
  • Verify mounting height is between 1.80m and 2.50m.

Se il problema persiste dopo aver provato queste soluzioni, contattare l'assistenza clienti o un elettricista qualificato.

8. Specifiche

Technical specifications for the SEBSON Outdoor Motion Detector IR_OUT_IA:

CaratteristicaSpecificazione
MarcaSEBSON
Numero di modelloIR_OUT_IA
Fonte di alimentazioneElettrico con cavo
Voltage230 Volt
Peso dell'articolo164 grammi (circa 5.8 once)
Dimensioni del prodotto3.9 x 2.91 x 2.4 pollici (circa 99 x 74 x 61 mm)
Portata massima14 metri
Angolo di rilevamento240°
LUX Adjustment Range3 - 2000 LUX
Regolazione del ritardo di tempo10 secondi - 15 minuti
Grado di protezione IPGrado di protezione IP65
Carico massimo (incandescente)2000W
Carico massimo (LED)1000W
Tipo di montaggioMontaggio a parete
Dispositivi compatibiliLight, Security System, Smart Home Hub
Usi consigliatiGarden, Driveway, Garage

9. Garanzia e supporto

Per informazioni sulla garanzia e sull'assistenza clienti, consultare la documentazione fornita con l'acquisto o contattare il rivenditore. Conservare la prova d'acquisto per eventuali reclami in garanzia.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.