The RD600 EMF Meter is a compact, handheld device designed for the simultaneous detection of electric and magnetic field radiation. It features a clear LCD graphic display, sound and light alarm functions, and a simple one-button operation for ease of use. This device helps assess the safety level of electromagnetic radiation in various environments.
Le caratteristiche principali includono:
- Dual-use functionality for electric and magnetic field detection.
- Automatic sound and light alarm when radiation exceeds safety thresholds.
- LCD graphic display showing radiation value trends and safety evaluations.
- Built-in electromagnetic radiation sensor for accurate readings.
2. Informazioni sulla sicurezza
Please read and understand all safety instructions before operating the RD600 EMF Meter. Failure to follow these instructions may result in inaccurate readings or damage to the device.
- Do not attempt to open or modify the device. Internal components are not user-serviceable.
- Tenere il dispositivo lontano dall'acqua e dall'umidità eccessiva.
- Evitare di esporre il dispositivo a temperature estreme o alla luce solare diretta per periodi prolungati.
- This device is for informational purposes and should not be used as a substitute for professional safety assessments or medical advice.
- Smaltire la batteria e il dispositivo secondo le normative locali.
3. Impostazione
3.1 Ricarica del dispositivo
The RD600 EMF Meter is equipped with a built-in 3.7V, 320mAh lithium battery. Before first use, or when the battery indicator shows low power, charge the device using the provided Type-C USB cable.
- Connect the Type-C end of the USB cable to the charging port on the side of the RD600 device.
- Connect the other end of the USB cable to a standard 5V DC USB power adapter (not included) or a computer USB port.
- The charging indicator on the device will show charging status. Allow sufficient time for a full charge.

Figure 1: Connecting the Type-C charging cable to the RD600 EMF Meter.
3.2 Accensione/Spegnimento
Press and hold the power button located on the front of the device to turn it on or off.
4. Istruzioni per l'uso
4.1 Esecuzione delle misurazioni
Once powered on, the RD600 will automatically begin detecting electric and magnetic fields. The LCD screen will display the current readings.
- Hold the device firmly and point it towards the area or object you wish to measure.
- The display will show the electric field (E) in V/m and the magnetic field (H) in uT/mG.
- Move the device slowly around the area to identify sources of radiation.

Figure 2: RD600 EMF Meter in use, detecting radiation from common household devices.
4.2 Interpretazione delle letture e degli allarmi
The RD600 provides a visual and audible indication of radiation levels:
- Schermo LCD: The screen shows numerical values for electric and magnetic fields. It also includes a graphic display of radiation value trends and an evaluation (e.g., "Harmful" or "Safe") to indicate the current radiation level relative to safety thresholds.
- Allarme sonoro e luminoso: If the detected radiation levels exceed predefined safety values, the device will emit an audible alarm and a visual light indicator will activate. This serves as an immediate warning.
Refer to local and international guidelines for specific safe exposure limits to electromagnetic fields.
5. Manutenzione
5.1 Pulizia
Per pulire il dispositivo, utilizzare un panno morbido e asciutto. Non utilizzare detergenti abrasivi, solventi o immergere il dispositivo in acqua.
5.2 Conservazione
Store the RD600 in a cool, dry place away from direct sunlight and extreme temperatures when not in use. If storing for extended periods, ensure the battery is partially charged to prolong its lifespan.
6. Risoluzione Dei Problemi
- Il dispositivo non si accende: Assicurati che la batteria sia sufficientemente carica. Collega il dispositivo a una fonte di alimentazione tramite il cavo Type-C e riprova.
- Nessuna lettura visualizzata: Check if the device is powered on. Ensure there are potential EMF sources in the vicinity. If the issue persists, the device may require service.
- L'allarme suona continuamente: This indicates high levels of electromagnetic radiation. Move away from the source or investigate the cause of the high readings.
- Letture imprecise: Ensure no other electronic devices are interfering with the measurement. Calibrate the device if a calibration option is available (refer to advanced settings if applicable, though not detailed in this manual).
7. Specifiche
| Parametro | Valore |
|---|---|
| Campo elettrico | 1-1999 V/m |
| Campo magnetico | 0.1-999.9 mG |
| Precisione del campo elettrico | 1V/m |
| Precisione del campo magnetico | 0.01 uT / 0.1 mG |
| Temperatura di esercizio | -10 a 60 ℃ |
| Umidità di esercizio | Meno dell'80% di umidità relativa |
| Batteria | Batteria al litio integrata da 3.7 V, 320 mAh |
| Volume di caricatage | CC 5V |
| Corrente di carica | Meno di 1A |
| Dimensioni | 90 x 60 x 23 mm (circa 3.54 x 2.36 x 0.91 pollici) |
| Peso | Circa. 83 g (0.18 libbre) |
8. Garanzia e supporto