1. Introduzione
Water activity (aw) is a critical parameter indicating the free water content in a substance, directly influencing microbial growth and product stability. The VTSYIQI Intelligent Water Activity Tester Model VD-90P is designed for precise measurement of water activity in various materials, including paste, dough, and other food products. This instrument features a high-precision WSC-4 sensor, a mini printer for data recording, and an intuitive LCD display for ease of use. This manual provides detailed instructions for the proper setup, operation, and maintenance of your VD-90P water activity meter.
2. Prodotto finitoview
2.1 Componenti
The VTSYIQI Intelligent Water Activity Tester Model VD-90P package typically includes the following components:
- Main Host Unit (VD-90P)
- WSC-4 Water Activity Sensor
- Mini stampante
- Cavi di alimentazione
- Manuale d'uso
- Calibration Salts (Sodium Chloride, Magnesium Chloride)
- Sampi Piatti
- Staffa regolabile

Figure 1: Complete VD-90P Water Activity Tester Kit

Figure 2: VD-90P Main Unit with LCD and Adjustable Bracket
2.2 Caratteristiche principali
- Campo di misura: 0-0.980aw (non-condensing environment)
- Precisione della misurazione: ±0.015aw (@25°C)
- Intervallo di temperatura: 0-50°C
- Precisione della temperatura: ±0.5°C
- Ripetibilità: ≤0.015
- Coefficiente di temperatura: ≤0.0005/°C
- Punti di misurazione: 1
- Misurazione rapida: Results in approximately 10 minutes
- Integrated Mini Printer for convenient data recording
- High Brightness LCD Display for intuitive operation
- Automatic Compensation for Environmental Parameters
- English Menu for user-friendly navigation
- Versatile application for solid, liquid, lump, and powder samples

Figure 3: Key Features of the VD-90P

Figure 4: Applicable Sampi tipi
3. Impostazione
- Disimballare i componenti: Carefully remove all components from the packaging. Verify that all listed items in Section 2.1 are present and undamaged.
- Posizionamento: Place the main host unit on a stable, level, and vibration-free surface, away from direct sunlight, heat sources, and strong electromagnetic fields.
- Collegare il sensore: Connect the WSC-4 water activity sensor cable to the designated sensor port on the main unit. Ensure a secure connection.
- Connetti stampante: Connect the mini printer to the main unit using the provided cable.
- Collegamento elettrico: Connect the power cable to the main unit and then to a suitable power outlet (110V AC or 220V AC, depending on your model and region).

Figura 5: Collegamenti del pannello posteriore
4. Funzionamento
- Accensione: Press the power switch to turn on the device. The LCD display will illuminate.
- Navigazione nel menu: Use the "Selection" buttons (up/down arrows) to navigate through the menu options and the "Confirmation" button to select an option.
- Preparare Sampon: Metti la tua sample into a clean, dry sample dish. Ensure the sample fills the dish adequately without overflowing.
- Inserisci Sampon: Posizionare con attenzione le sample dish into the sensor chamber of the WSC-4 sensor. Close the sensor lid securely to create a sealed environment.
- Inizia la misurazione: From the main menu, select "Measurement" and confirm. The device will begin the measurement process, which typically takes about 10 minutes.
- Leggi i risultati: Once the measurement is complete, the water activity (Aw) and temperature (T) will be displayed on the LCD screen.
- Dati di stampa: If desired, use the integrated mini printer to print the measurement results. Refer to the printer's specific instructions for paper loading and operation.
4.1 Guida video operativa
Video 1: This video demonstrates the basic operation and calibration process of the VTSYIQI VD-90P Water Activity Meter, including sample placement and menu navigation.
5. Calibrazione
The VTSYIQI VD-90P Water Activity Tester is factory-calibrated for immediate use. Regular recalibration is recommended approximately every 5 months to ensure continued accuracy. For calibration, you will need pure Sodium Chloride (NaCl) and Magnesium Chloride (MgCl2) solutions, which can be purchased locally as liquid powders are restricted for air transport.
- Access Calibration Menu: From the main menu, select "Calibration" and confirm.
- Select Calibration Standard: The display will show options for calibration standards (e.g., NaCl, MgCl2). Select the appropriate standard you are using.
- Prepare Calibration Sampon: Place the chosen calibration solution into a clean sampil piatto.
- Insert Calibration Sampon: Posizionare la sample dish into the sensor chamber and close the lid.
- Inizia la calibrazione: Follow the on-screen prompts to initiate the calibration process. The device will measure the standard and adjust its readings accordingly.
- Conferma calibrazione: Once calibration is complete, the device will indicate success. Repeat the process for other calibration standards if necessary.
6. Manutenzione
- Pulizia del sensore: Regularly clean the WSC-4 sensor and sample chamber with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the sensor.
- Magazzinaggio: Store the VD-90P unit in a clean, dry, and temperature-stable environment when not in use. Keep it away from dust and corrosive substances.
- Manutenzione della stampante: Ensure the mini printer has sufficient paper. Replace paper rolls as needed, following the printer's specific instructions.
- Spegni: Always turn off the device using the power switch when not in operation.
7. Risoluzione Dei Problemi
If you encounter issues with your VTSYIQI VD-90P Water Activity Tester, consider the following common troubleshooting steps:
- Il dispositivo non si accende: Check the power cable connection to both the unit and the power outlet. Ensure the power switch is in the 'On' position.
- Letture imprecise: Verify that the sensor is clean and properly connected. Ensure the sample dish is correctly seated and the sensor lid is closed tightly. Consider performing a calibration as described in Section 5.
- Printer Not Working: Check the printer cable connection to the main unit. Ensure the printer has paper and is powered on. Refer to the mini printer's manual for specific troubleshooting.
- "No Condensing" Error: This indicates that the environmental conditions might be outside the recommended operating range. Ensure the testing environment is stable and non-condensing.
For persistent issues or error messages not covered here, please refer to the comprehensive user manual included with your device or contact VTSYIQI customer support.
8. Specifiche
| Parametro | Valore |
|---|---|
| Modello | VD-90P |
| Measuring Range (Water Activity) | 0-0.980aw (no condensing) |
| Measurement Accuracy (Water Activity) | ±0.015aw (@25°C) |
| Intervallo di temperatura | 0-50°C |
| Precisione della temperatura | ±0.5°C |
| Ripetibilità | ≤0.015 |
| Coefficiente di temperatura | ≤0.0005/°C |
| Punti di misurazione | 1 |
| Display | Large-screen LCD 128×64DOTS |
| Modalità di uscita | Micro stampante |
| Volume di fornituratage | 110V AC±10% / 220V AC±10% (Optional) |
| Consumo energetico | ≤15 W |
| Peso dell'articolo | 26.4 libbre (circa 12 kg) |
| Dimensioni del prodotto (L x P x A) | 15.75 x 3.94 x 9.84 pollici (circa 40 x 10 x 25 cm) |
| Materiale | Plastica |
| Componenti inclusi | Main Host, WSC-4 Water Activity Sensor, Mini Printer, Power Cables, User Manual, Calibration Salts, Sampi Piatti |
9. Garanzia e supporto
The VTSYIQI Intelligent Water Activity Tester Model VD-90P comes with warranty protection. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact VTSYIQI customer service. For technical support, inquiries, or service requests, please reach out to VTSYIQI directly through their official channels.