1. Introduzione
The FNIRSI 1014D is a versatile 2-in-1 device, combining a digital oscilloscope with a DDS (Direct Digital Synthesis) function signal generator. Designed for a wide range of applications from electronic DIY to scientific research, this instrument offers powerful features for waveform analysis and signal generation. This manual provides essential information for the safe and effective operation, setup, and maintenance of your FNIRSI 1014D.
Image 1.1: FNIRSI 1014D Digital Oscilloscope with connected probes, showcasingrazie al suo design compatto e alla sua doppia funzionalità.
2. Informazioni sulla sicurezza
Si prega di leggere attentamente tutte le istruzioni di sicurezza prima di utilizzare il dispositivo. La mancata osservanza di queste istruzioni può causare scosse elettriche, incendi o danni al prodotto.
- Utilizzare sempre l'adattatore di alimentazione fornito. L'utilizzo di un adattatore non corretto potrebbe danneggiare il dispositivo o rappresentare un rischio per la sicurezza.
- Non utilizzare il dispositivo in ambienti bagnati o damp condizioni.
- Evitare di esporre il dispositivo alla luce solare diretta o a temperature elevate.
- Garantire una ventilazione adeguata per evitare il surriscaldamento.
- Non tentare di aprire o riparare il dispositivo da soli. Per qualsiasi intervento di assistenza, rivolgersi a personale qualificato.
- Before connecting probes, ensure the device is powered off and the circuit under test is de-energized if necessary.
- Be aware of the maximum input voltage ratings for the oscilloscope channels and probes to prevent damage.
3. Contenuto della confezione
Verifica che tutti gli articoli elencati di seguito siano presenti nel tuo pacco:
- 1 x FNIRSI-1014D Oscilloscope
- 2 x 100MHz Probes (1X and 10X)
- 1 x pinza
- 1 x 5V 2A Power Adapter (US standard plug)
- 1 cavo dati USB di x
- 1 x Manuale utente in inglese
4. Prodotto finitoview
4.1 Caratteristiche principali
- Alte prestazioni: in tempo realeampling rate up to 1 GSa/s and 100 MHz * 2 analog bandwidth. Supports single, normal, and auto trigger modes for both periodic analog and aperiodic digital signals.
- Integrated DDS Function Signal Generator: 2.5 VPP output, 1 Hz frequency steps, supports 14 types of function signals and customizable cut signals, with storage for up to 1000 custom signals.
- Easy Measurement: Cursor measurement function allows direct reading of peak-to-peak values and frequencies without manual scale unit conversion.
- Display intuitivo: High-efficiency Auto button for quick waveform display. Features a 7-inch high-definition LCD screen with 800 x 480 resolution.
- Analisi avanzata: Lissajous Graphics Display for comparing amplitude, frequency, and phase of two signals. FFT (Fast Fourier Transform) function for estimating harmonic content.
4.2 Disposizione del pannello frontale
The front panel of the FNIRSI 1014D features the main display, control buttons, and input connectors for the oscilloscope channels and signal generator output.
Immagine 4.1: Dettagliata view of the FNIRSI 1014D front panel, highlighting the 7-inch display, control knobs, function buttons, and input connectors for channels 1 and 2, along with the signal generator output.
4.3 Collegamenti del pannello posteriore
The rear panel provides essential connections for power and data transfer.
Immagine 4.2: posteriore view of the FNIRSI 1014D, showing the power input port and the USB port for data export.
4.4 Applicazioni
The FNIRSI 1014D is suitable for a variety of applications, including:
- Progetti fai da te elettronici
- Riparazione elettrodomestici
- Car repair and diagnostics
- Debug delle apparecchiature
- Ricerca scientifica
- Sviluppo del prodotto
Image 4.3: Visual representation of the diverse applications for the FNIRSI 1014D, ranging from hobbyist electronics to professional diagnostics.
5. Impostazione
5.1 Collegamento di alimentazione
- Connect the provided 5V 2A power adapter to the DC input port on the rear panel of the oscilloscope.
- Collegare l'adattatore di alimentazione a una presa di corrente adatta.
- Premere il tasto ENERGIA button on the front panel to turn on the device. The display will illuminate.
5.2 Probe Connection and Calibration
Before taking measurements, it is crucial to properly connect and calibrate the oscilloscope probes.
- Connect the BNC connector of the probe to the desired input channel (CH1 or CH2) on the front panel.
- Attach the ground clip of the probe to the ground reference of your circuit.
- For 10X probes, ensure the switch on the probe is set to 10X. The oscilloscope should also be configured for 10X attenuation in the channel settings.
- Calibrazione della sonda: Connect the probe tip to the calibration signal output (usually a square wave test point on the oscilloscope itself, or use the internal signal generator). Adjust the compensation trimmer on the probe until a perfect square wave is displayed on the screen.
6. Istruzioni per l'uso
6.1 Funzioni di base dell'oscilloscopio
The FNIRSI 1014D features intuitive controls for waveform acquisition and display.
- Pulsante automatico: Premere il tasto AUTO button for automatic setup of vertical, horizontal, and trigger parameters to quickly display a stable waveform.
- Vertical Controls (VOLTS/DIV): Use the vertical knobs (e.g., CH1/CH2) to adjust the vertical scale (voltage per division) and position of the waveform.
- Horizontal Controls (SEC/DIV): Use the horizontal knob to adjust the time base (time per division) and position of the waveform.
- Controlli del grilletto: Adjust the trigger level and mode (Single, Normal, Auto) to stabilize repetitive waveforms or capture single-shot events. The trigger edge can be set to rising or falling.
Image 6.1: The 7-inch HD screen of the FNIRSI 1014D, showing various menu options for waveform settings, measurements, and system configurations.
6.2 DDS Signal Generator Functions
The built-in DDS signal generator can produce various waveforms for testing circuits.
- Connect the signal generator output (GEN) to the circuit you wish to test.
- Access the signal generator menu (refer to the on-screen interface for specific button/menu navigation).
- Select the desired waveform type (e.g., Sine, Square, Triangle, Sawtooth).
- Adjust the frequency (in 1 Hz steps) and amplitude (fixed at 2.5 VPP) as needed.
- Customizable signals can be stored and recalled.
6.3 Measurement and Analysis Functions
- Misurazione del cursore: Activate cursor measurements to precisely determine voltage and time differences on the waveform. The device will display values directly.
- FFT (Trasformata di Fourier veloce): Use the FFT function to analyze the frequency components of a signal, useful for identifying harmonics and noise.
- Lissajous Graphics: This mode allows for the comparison of two signals' amplitude, frequency, and phase relationships, typically by displaying one signal on the X-axis and the other on the Y-axis.
6.4 Salvataggio ed esportazione dei dati
The FNIRSI 1014D supports saving waveforms and exporting data.
- Memorizzazione delle forme d'onda: The device can store up to 1000 waveform pictures and 1000 waveform data sets.
- Esportazione USB: Connect a USB drive to the rear panel's USB port to export saved images or waveform data for further analysis on a computer.
7. Manutenzione
- Pulizia: Utilizzare un panno morbido e asciutto per pulire il dispositivo. Per lo sporco ostinato, un panno leggermenteamp È possibile utilizzare un panno con un detergente delicato, assicurandosi che nessun liquido penetri nel dispositivo.
- Magazzinaggio: Conservare l'oscilloscopio in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.
- Cura della sonda: Maneggiare le sonde con cura. Evitare di piegare o sollecitare eccessivamente i cavi. Mantenere pulite le punte delle sonde.
8. Risoluzione Dei Problemi
If you encounter issues with your FNIRSI 1014D, refer to the following common problems and solutions:
- Nessun display/dispositivo non acceso:
- Assicurarsi che l'adattatore di alimentazione sia collegato correttamente e inserito in una presa di corrente funzionante.
- Verificare che il pulsante di accensione sia premuto completamente.
- Controllare se l'adattatore di alimentazione è danneggiato.
- Nessuna forma d'onda visualizzata:
- Check if the probe is correctly connected to the input channel and the circuit under test.
- Ensure the probe's ground clip is connected to the circuit's ground.
- Premere il tasto AUTO pulsante per regolare automaticamente le impostazioni.
- Regola le scale verticale (VOLTS/DIV) e orizzontale (SEC/DIV).
- Check trigger settings (level, mode).
- Distorted or Unstable Waveform:
- Recalibrate the probe if using a 10X setting.
- Adjust the trigger level and mode for stability.
- Ensure the probe is properly grounded.
- Check for external noise sources.
- Il generatore di segnale non emette:
- Verificare che il cavo di uscita sia collegato correttamente.
- Ensure the signal generator function is enabled and configured in the menu.
9. Specifiche
Detailed technical specifications for the FNIRSI 1014D:
| Caratteristica | Specificazione |
|---|---|
| Modello | FNIRSI-1014D |
| Larghezza di banda analogica | 100MHz * 2 Channels |
| Numero di canali | 2 |
| S in tempo realeamptasso di ling | 1 GSa/s |
| Sensibilità verticale | 50 mV/div ~ 500 V/div |
| Horizontal Time Base Range | 50S/div ~ 10nS/div |
| Volume massimo di provatage | 40V (1X probe), 400V (10X probe) |
| Profondità di archiviazione | 240Kbit |
| Resistenza di ingresso | 1 MΩ |
| ADC Precision | 8 bit |
| Modalità di accoppiamento | Corrente alternata/corrente continua |
| Modalità trigger | Single, Normal, Auto |
| Bordo del grilletto | Salita/discesa |
| Trigger esterno voltage | 0~40 V |
| Porte di estensione | USB Image Export |
| DDS Signal Generator Output | 2.5 VPP |
| DDS Signal Frequency Steps | Frequenza 1 Hz |
| DDS Signal Types | 14 types + Customizable |
| Display | LCD HD da 7 pollici |
| Risoluzione dello schermo | 800x480 |
| Materiale | addominali |
| Dimensioni | Dimensioni: 310 mm x 145 mm x 70 mm |
| Peso | 1.57 kg |
Image 9.1: On-screen display of key specifications for the FNIRSI 1014D, providing a quick reference for its capabilities.
10. Garanzia e supporto
FNIRSI products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official FNIRSI websito. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.