1. Introduzione
This manual provides essential information for the safe and efficient operation of your Aninerel 12000W Solar Hybrid Inverter. Please read this manual thoroughly before installation and use, and retain it for future reference. This inverter is designed to convert 48V DC power from solar panels or batteries into 120V single-phase or 240V split-phase AC power, providing a continuous output of 12,000W and a peak output of 24,000W.

Figura 1: Fronte view of the Aninerel 12000W Solar Hybrid Inverter.
2. Informazioni sulla sicurezza
Always observe safety precautions during installation, operation, and maintenance. Failure to follow these instructions may result in serious injury or damage to the equipment.
- Assicurarsi che tutti i collegamenti elettrici siano sicuri e correttamente polarizzati.
- Non tentare di aprire o riparare l'inverter da soli. Rivolgersi a personale qualificato.
- The inverter is equipped with comprehensive protection mechanisms including overvoltage, sottovoltage, reverse polarity, and short circuit protection.
- This unit is UL1741 certified for reliable and safe use.
- Install the inverter in a well-ventilated area, away from flammable materials and moisture. The IP65 dustproof enclosure allows for indoor and semi-outdoor use.

Figure 2: Inverter protection features including overcharge, overload, overcurrent, overvoltage, short circuit, overheat, overspeed, and undervoltage protezione.
3. Prodotto finitoview
3.1 Caratteristiche principali
- Output & Voltage Flessibilità: 12,000W continuous, 24,000W peak output. Converts 48V DC to 120V single-phase or 240V split-phase AC.
- Dual MPPT & High-Efficiency Charging: Two MPPT solar charging controllers with a maximum 220A battery charging current. Supports high-voltage PV arrays up to 500VDC.
- Capacità parallela: Connect up to 6 units for a maximum output of 72kW. Supports 120V single-phase, 240V split-phase, or 208V three-phase output with multiple units.
- Advanced Design & Operation: Features an OLED light-touch screen for intuitive monitoring and parameter adjustment. WIFI-enabled for real-time status checks.
- Durability & Safety: IP65 dustproof enclosure, smart variable-speed cooling, and comprehensive protection mechanisms. UL1741 certified.
- Funzionamento a basso rumore: Incorporates noise reduction technology for quiet performance.

Figura 3: Oltreview of key features including battery compatibility, grid connection (no feedback), scalability, versatile design, flexible settings, and wireless communication.

Figure 4: Illustration of the inverter's low-noise operation, comparing its sound level (45dB) to other common sounds.
3.2 Componenti del prodotto

Figura 5: dettagliata view of the inverter's components and ports.
- Schermo di visualizzazione
- pilota lamp
- Porta di uscita AC
- Porta di ingresso CA
- WIFI port (optional)
- Porta di comunicazione USB
- Porta di comunicazione RS485-1
- RS485-2/CAN communication port
- Porta di contatto a secco
- CT current sensing for self-consumption (optional)
- Interruttore a bilanciere ON/OFF
- Photovoltaic (PV) parameters
- Parametri della batteria
- Porta di comunicazione parallela (solo modulo parallelo)
- Interruttore di ingresso CA
- Tenuta della vite di messa a terra
3.3 Accessori inclusi

Figure 6: Standard accessories included with the inverter.
- Manuale di istruzioni
- Kit di installazione
- Parallel Cable (x1)
- Anti-reverse current CT (x2)
- WIFI Module (x1)
4. Installazione
Proper installation is crucial for the inverter's performance and safety. Refer to the detailed wiring diagrams in the full instruction manual for specific connection procedures.
- Montaggio: Securely mount the inverter in a location that allows for adequate ventilation and access for connections.
- Collegamento della batteria: The inverter is compatible with 48V AGM, GEL, Lead-acid, Li-ion, and LiFePO4 batteries. Ensure correct polarity when connecting.
- Ingresso FV: Connect your solar panels to the designated PV input ports. The inverter supports up to 6,000W+6,000W PV input with a maximum of 500VDC.
- Ingresso/uscita CA: Connect the AC input from the grid or generator and the AC output to your loads.
- Messa a terra: Ensure the inverter is properly grounded using the grounding screw hold.
- Funzionamento senza batteria: The inverter supports direct solar-to-load use without a battery, depending on solar availability.

Figure 7: The inverter supports various 48V battery types including GEL, FLD, LI, and SLD.

Figura 8: Esample of a single-phase hybrid inverter system showing power supply from grid and selling electricity to the state grid.
5. Setup Preferences
The inverter allows you to configure charging and load priorities to optimize energy management.

Figure 9: Setup preferences for controlling battery charging and appliance power sources.
5.1 Charging Priority
Control how the battery bank is charged from different power sources:
- Priorità solare: The inverter prioritizes solar power for charging. AC input will only charge the battery when solar power is no longer available.
- Solar and AC Input: The inverter charges the battery bank from both solar and AC power simultaneously.
- Solo solare: The inverter charges the battery bank exclusively from available solar power.
5.2 Load Priority
Control how your appliances receive power:
- Priorità solare: The inverter supplies the load first with solar power. If solar is insufficient, it will compensate from the AC input.
- Priorità CA: The inverter redirects AC input to power all loads and uses DC inputs when AC input power is unavailable.
- Priorità DC: The inverter prioritizes drawing power from the battery first. If the battery level is low, it will convert from AC input to power loads.
6. Funzionamento
The inverter features an OLED light-touch screen for monitoring and adjusting parameters. The intuitive interface allows for easy control of the system's functions.
- Accensione/spegnimento: Use the ON/OFF rocker switch (component 11) to power the unit.
- Monitoraggio dello schermo: The display screen (component 1) shows real-time operational data such as input/output voltage, corrente, potenza e stato della batteria.
- Regolazione dei parametri: Navigate through the menu on the OLED screen to customize settings like charging current, output voltage range, and priority modes.
7. Monitoraggio Wi-Fi
The inverter includes a Wi-Fi module for remote monitoring of its operating status. This allows you to check system performance anytime, anywhere.
- Download dell'app: Download the "Smart Value" application from the Google Play Store or Apple App Store.
- Connessione: Follow the in-app instructions to connect your inverter to the Wi-Fi network.
- Dati in tempo reale: Monitor parameters such as PV input, battery charge/discharge, AC output, and system alerts.
- Web Monitoraggio: Web-based monitoring is also available at ValueClouds.com.

Figure 10: Wi-Fi module connection and mobile app monitoring for the inverter.
8. Collegamento parallelo
The Aninerel 12000W Solar Hybrid Inverter supports parallel connection of up to 6 units to meet higher power demands, expanding the maximum output power to 72kW.

Figure 11: Various parallel connection configurations for single-phase, split-phase, and three-phase systems.
- Single-Phase Parallel: Up to 6 units can be connected in parallel for 120V residential systems, delivering up to 72kW.
- Split-Phase Parallel: For 240V systems, units can be configured in series and parallel. For example, two inverters in each phase (two pairs in split-phase).
- Three-Phase Output: Three units can be configured to achieve 208V three-phase output.
These configurations allow for scalable power solutions for both residential and small commercial solar systems.
9. Manutenzione
Una manutenzione regolare garantisce la longevità e le prestazioni ottimali del vostro inverter.
- Pulizia: Periodically clean the exterior of the inverter to prevent dust accumulation, especially around ventilation openings. The IP65 rating provides dust protection.
- Ventilazione: Ensure that the inverter's cooling system (smart variable-speed fans) operates without obstruction. Avoid blocking air inlets and outlets.
- Verifiche della connessione: Controllare regolarmente tutti i collegamenti elettrici per verificarne la tenuta e l'assenza di segni di corrosione.
- Aggiornamenti del firmware: Controllare il produttore website or the Smart Value app for any available firmware updates to ensure optimal performance and new features.
10. Risoluzione Dei Problemi
If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific error codes and detailed solutions, consult the comprehensive manual.
- Nessuna potenza in uscita: Check AC input breaker, battery connections, and PV input. Ensure the inverter is switched ON.
- Codici di errore sul display: Note down any error codes displayed on the OLED screen and refer to the manual's troubleshooting section for their meaning and recommended actions.
- Protezione da sovraccarico: If the inverter trips due to overload, reduce the connected load and restart the unit.
- Batteria non in carica: Verify PV input, MPPT settings, and battery connections. Check battery health.
- Problemi di connettività Wi-Fi: Ensure the Wi-Fi module is correctly installed and within range of your router. Restart the module and the app.
11. Specifiche
Key technical specifications for the Aninerel 12000W Solar Hybrid Inverter (Model ANJ-12000W-LVP-WIFI).

Figure 12: Comprehensive technical specifications of the inverter.
| Parametro | Valore |
|---|---|
| Modello | ANJ-12000W-LVP-WIFI |
| Potenza di uscita nominale | Split phase 12000VA/12000W, Single phase: 7200VA/7200W (limited by wiring terminals) |
| Potenza massima di picco | Split phase 18000VA, Single phase: 18000VA |
| Volume di uscita nominaletage | 120Vac (L1/N, L2/N) / 240Vac (L1/L2) |
| Capacità di carico dei motori | 6 CV |
| Frequenza CA nominale | Frequenza di campionamento: 50 Hz/60 Hz |
| Capacità parallela | 1~6 units |
| Volume di uscitatage Forma d'onda | Onda sinusoidale pura |
| Protezione da sovraccarico | 102%<load<125%)+10%: report error, turn off output after 5 minutes; (125%<load<150%)+10%: report error, turn off output after 10 seconds; load>150%)+10%: report error, turn off output after 5 seconds; |
| Tipo di batteria | Lithium/Lead-acid batteries |
| Vol. nominale della batteriatage | 51.2V (Vol. minimo inizialetage 44V) |
| Mains/Generator Input Range | (90 Vca~140 Vca)±2% |
| Certificazione di sicurezza | UL STD.1741 |
| Massimo. Corrente di carica MPPT | 160A |
| Corrente di carica massima della rete/generatore | 160A |
| Max. Hybrid Charge Current | 220A |
| Numero di inseguitori MPPT | 2 |
| Max. Potenza del campo fotovoltaico | 6000W × 2 |
| Corrente di ingresso massima | 22A × 2 |
| massimo volumetage di circuito aperto | 500 Vcc |
| MPPT voltage Gamma | 90Vcc~500Vcc |
| Max. Bypass Phase Overload Current | 2P, 63A/63A (L1/L2) |
| Efficienza di monitoraggio MPPT | 95% |
| Support Communication | WiFi Modules/RS485/CAN/USB/Dry contact |
| Dimensioni | 24.4 × 17.7 × 5.19 pollici |
| Peso | 23.8KG / 52.47LB |
12. Garanzia e supporto
Aninerel is committed to providing excellent customer support. For warranty information, technical assistance, or any inquiries, please contact us through the following channels:
- E-mail: anenji168@outlook.com
- Telefono/WhatsApp: +86 188 0375 9233
- Orari di apertura: PDT: 9 AM - 6 PM
Our technical support team is available to assist with setup, operation, and troubleshooting.

Figure 13: Aninerel customer support contact details.