FNIRSI DST-210

FNIRSI DST-210 3-in-1 Oscilloscope, Multimeter, Signal Generator User Manual

Modello: DST-210

1. Introduzione

The FNIRSI DST-210 is a versatile 3-in-1 portable test instrument, combining the functionalities of an oscilloscope, a digital multimeter, and a DDS signal generator. This device is designed for electronics enthusiasts, engineers, and technicians requiring a compact yet powerful tool for various measurement and diagnostic tasks. It features a 2.8-inch TFT color display, a 3000mAh rechargeable battery, and a user-friendly interface.

FNIRSI DST-210 3-in-1 device showing oscilloscope, multimeter, and signal generator functions

Figura 1: Oltreview of the FNIRSI DST-210 highlighting its 3-in-1 capabilities.

2. Impostazione

2.1 Disimballaggio

Carefully remove the FNIRSI DST-210 from its packaging. Verify that all components are present, including the main unit, test leads, and USB Type-C charging cable.

2.2 Caricamento della batteria

The device is equipped with a built-in 3000mAh lithium-ion battery. Before first use, fully charge the device using the provided Type-C USB cable and a compatible 5V/1A power adapter (not included). The charging indicator will show the battery status.

FNIRSI DST-210 showing Type-C charging port and battery icon

Figure 2: Device showing Type-C charging port and battery information.

2.3 Accensione/Spegnimento

Premere e tenere premuto il tasto Pulsante di accensione located on the side of the device to turn it on or off. The device features an auto-shutdown function, adjustable from 15 minutes to 1 hour, to conserve battery life.

3. Funzionamento

3.1 Interfaccia generale e navigazione

The DST-210 features a 2.8-inch TFT color screen. Use the central Quadrante di funzione E ENTRARE button for mode selection and parameter adjustment. The MODALITÀ button switches between main functions (Oscilloscope, Multimeter, Signal Generator) or sub-modes within a function. The RUN/SAVE button is used for starting/stopping measurements or saving data.

FNIRSI DST-210 labeled diagram showing buttons, ports, and dial

Figure 3: Labeled diagram of the FNIRSI DST-210's controls and ports.

3.2 Modalità oscilloscopio

To enter Oscilloscope mode, rotate the Quadrante di funzione to the "Oscilloscope" position or press the MODALITÀ button until the oscilloscope interface is displayed. Connect the probe to the Scope Channel Interface.

  • Larghezza di banda: 10 MHz
  • Samptasso di ling: 48MSa / s
  • Volume massimo in ingressotage: 400V
  • Sensibilità verticale: da 10 mV/div a 10 V/div
  • Registrazione della forma d'onda: Utilizzare il RUN/SAVE button to capture and save waveform images.
  • Applicazioni: Ideal for CAN bus noise detection, audio signal analysis, and power supply ripple visualization.
FNIRSI DST-210 in use for CAN bus, audio analysis, and power supply testing

Figura 4: Esamples of oscilloscope applications including CAN bus, audio, and power supply analysis.

3.3 Modalità multimetro digitale

Ruotare il Quadrante di funzione to the desired measurement type (e.g., V~ for AC Voltage, V- per DC Voltage, Ω for Resistance). Connect test leads to the appropriate input jacks (10A, mA, COM, VΩHz).

  • Display: 19,999 counts with Max/Min value display and curve recording.
  • Misure: Volume AC/DCtage, AC/DC Current, Resistance, Capacitance, Frequency, Diode, Temperature.
  • Funzioni speciali: Continuity test, Live/Neutral wire detection, Auto-ranging, Data Hold.
FNIRSI DST-210 displaying multimeter readings with curve and Max/Min values

Figure 5: Multimeter interface showing voltage measurement with data logging and curve display.

3.3.1 Specific Multimeter Measurements

  • Volume AC/DCtage: Select V~ or V- on the dial. Connect leads in parallel to the circuit.
  • Corrente CA/CC: Select A~ or A- on the dial. Connect leads in series with the circuit. Use 10A or mA input as appropriate.
  • Resistenza (Ω): Select Ω on the dial. Connect leads across the component.
  • Test di continuità: Select the continuity symbol on the dial. A buzzer sounds for low resistance.
  • Prova del diodo: Select the diode symbol. Measures forward voltage goccia.
  • Frequenza (Hz): Select Hz on the dial.
  • Capacità: Select the capacitance symbol.
  • Temperatura: Requires a K-type thermocouple (not included).
  • Rilevamento del filo fase/neutro: Use the dedicated function on the dial.
FNIRSI DST-210 performing various measurements: AC/DC Voltage, Continuity, AC/DC Current, Resistance

Figura 6: Esamples of multiple measurement types using the multimeter function.

3.4 Modalità generatore di segnale DDS

Ruotare il Quadrante di funzione to the "Signal Generator" position. Connect the output to the DDS SG Output Port.

  • Forme d'onda: Generates 13 types of waveforms (e.g., Sine, Square, Triangle, Sawtooth, Half-wave, Full-wave, Step wave).
  • Gamma di frequenza: Frequenza: da 0 a 50 kHz.
  • AmpGamma di luce: Regolabile da 0.1 V a 3.0 V.
  • Applicazioni: Utile per amplifier testing, filter tuning, and PWM simulation.
FNIRSI DST-210 displaying various signal generator waveforms

Figure 7: Signal generator interface showing different waveform options and adjustable parameters.

4. Manutenzione

4.1 Cura della batteria

To prolong battery life, avoid fully discharging the 3000mAh lithium-ion battery frequently. Recharge the device when the battery indicator is low. Store the device with a partial charge if not used for extended periods.

4.2 Pulizia

Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device openings.

4.3 Conservazione

Store the FNIRSI DST-210 in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it protected from dust and moisture.

5. Risoluzione Dei Problemi

  • Il dispositivo non si accende: Ensure the battery is charged. Connect the Type-C charger and try again. If the issue persists, press the Ripristina foro with a thin pin.
  • Letture imprecise: Check test lead connections. Ensure the correct measurement mode is selected. Calibrate if necessary (refer to advanced user guide if available).
  • Lo schermo è vuoto o bloccato: Try restarting the device. If unresponsive, use the Ripristina foro.
  • La batteria non si carica: Verify the Type-C cable and power adapter are functional. Ensure the charging port is clean.

6. Specifiche

CaratteristicaSpecificazione
ModelloOra legale-210
ProduttoreFNIRSI
DisplaySchermo TFT a colori da 2.8 pollici
Oscilloscopio
Larghezza di banda10 MHz
Samptasso di ling48MSa / s
Volume massimo in ingressotage400V
Sensibilità verticale10 mV/div - 10 V/div
Multimetro digitale
Visualizza i conteggi19,999
Funzioni di misurazioneVolume AC/DCtage, AC/DC Current, Resistance, Capacitance, Frequency, Diode, Temperature, Continuity, Live/Neutral
DDS Signal Generator
Forme d'onda13 tipi
Gamma di frequenzaFrequenza
Ampgamma di latitudine0.1V - 3.0V
Batteria3000 mAh agli ioni di litio (inclusi)
Porta di ricaricaTipo-C (5V/1A)
Spegnimento automaticoAdjustable (15 min to 1 hour)
Dimensioni19.8 x 11 x 8.9 cm (Confezione)
Peso630 grammi (Confezione)
Prima data disponibile10 settembre 2025

7. Garanzia e supporto

Information regarding specific warranty terms and customer support channels for the FNIRSI DST-210 is not available in the provided product data. Please refer to the product packaging or the manufacturer's official websito per informazioni dettagliate sulla garanzia e contatti di supporto.

  • Disponibilità ricambi: Informazioni non disponibili.
  • Aggiornamenti software: Informazione non disponibile.

© 2026 FNIRSI. All rights reserved. This manual is for informational purposes only.