STEPPERONLINE CL86Y, 34HS59-6004D-E1K-1M5

STEPPERONLINE CL86Y Closed Loop Stepper Motor Kit Instruction Manual

Model: CL86Y Driver & 34HS59-6004D-E1K-1M5 Motor

1. Finitaview

This manual provides instructions for the STEPPERONLINE Closed Loop Stepper Motor Kit, which includes a CL86Y Stepper Driver and a 34HS59-6004D-E1K-1M5 Nema 34 Closed Loop Stepper Motor. This kit is designed for applications requiring high precision, high torque, and reliable motion control, such as CNC machines, 3D printers, and automation equipment. The closed-loop system ensures no loss of steps by providing encoder feedback to the driver.

2. Configurazione e installazione

2.1 Componenti del kit

  • 1 x CL86Y Closed Loop Stepper Driver
  • 1 x 34HS59-6004D-E1K-1M5 Nema 34 Closed Loop Stepper Motor with 1.5 Meter Cables

2.2 Driver Overview (CL86Y)

The CL86Y driver features various input/output terminals and DIP switches for configuration. Familiarize yourself with the layout before making connections.

STEPPERONLINE CL86Y Stepper Driver with terminal labels and DIP switch settings

Figure 1: CL86Y Stepper Driver. This image displays the CL86Y driver, highlighting its various connection terminals for input, output, encoder, and high voltage, along with the DIP switch settings for pulse/revolution configuration.

2.3 Motor Overview (34HS59-6004D-E1K-1M5)

The Nema 34 closed-loop stepper motor is equipped with an integrated encoder for precise position feedback.

STEPPERONLINE Nema 34 Closed Loop Stepper Motor

Figure 2: Nema 34 Closed Loop Stepper Motor. This image shows the Nema 34 stepper motor, featuring its robust construction and integrated encoder at the rear.

2.4 Collegamenti di cablaggio

Ensure all connections are secure and correct before applying power. Incorrect wiring can damage the components.

Motor and encoder cables with exposed wires

Figure 3: Motor and Encoder Cables. This image displays the two sets of cables provided with the kit, showing the individual colored wires for motor and encoder connections.

2.4.1 Motor and Encoder Connection Diagram

Motor and Encoder Connection Table

Figure 4: Motor and Encoder Connection Table. This diagram provides a clear mapping of wire colors to their respective motor and encoder terminals (A+, A-, B+, B- for motor; EA+, VCC, GND, EB+, EB-, EA- for encoder).

Refer to the table below and Figure 4 for correct wiring:

Cablaggio del motore
terminaleColore del filo
A+Nero
A-Verde
B+Rosso
B-Blu
Cablaggio dell'encoder
SPILLOColore del filo
EA+Nero
VCCRosso
TerraBianco
MIB+Giallo
MI-Verde
EA-Blu

2.4.2 Collegamento dell'alimentazione

  • Connect the power supply to the AC/DC terminals on the CL86Y driver.
  • Ingresso volumetage: 20-80VAC or 30-110VDC. A typical operating voltage is 48VDC or 60VDC.
  • Ensure the power supply is capable of providing the required current for the motor (up to 8.5A peak output from the driver).

2.4.3 Collegamento del segnale di controllo

  • Connect your controller's pulse (PU+ / PU-), direction (DR+ / DR-), and enable (MF+ / MF-) signals to the corresponding terminals on the CL86Y driver.
  • The logic signal current is typically 10mA (range 7-16mA).

2.5 Driver Configuration (DIP Switches)

The CL86Y driver uses DIP switches (SW1-SW6) to configure microstep resolution and pulse/direction mode.

2.5.1 Pulse/Revolution Table (Microstep Settings)

Use SW2, SW3, SW4, SW5, and SW6 to set the desired microstep resolution. The table below shows common settings:

Pulse/Revolution Settings
Impulso/giroSW2SW3SW4SW5SW6
800ONONONONON
1600ONONONONSPENTO
3200SPENTOONONONON
6400ONSPENTOONONON
12800SPENTOSPENTOSPENTOONON
25600ONSPENTOSPENTOONON
51200SPENTOSPENTOONONON
1000ONONSPENTOSPENTOSPENTO
2000SPENTOONSPENTOSPENTOSPENTO
4000ONSPENTOSPENTOSPENTOSPENTO
5000SPENTOSPENTOSPENTOSPENTOSPENTO
8000ONONONSPENTOSPENTO
10000SPENTOONONSPENTOSPENTO
20000ONSPENTOONSPENTOSPENTO
40000SPENTOSPENTOSPENTOSPENTOSPENTO

Nota: The maximum step count is 40,000 steps, allowing for extremely accurate operation with encoder feedback.

2.5.2 Pulse/Direction Mode (SW1)

  • SW1: OFF = PU+DR- (Pulse/Direction mode where Pulse is positive and Direction is negative)
  • SW1: ON = CW/CCW (Clockwise/Counter-Clockwise mode)

3. Istruzioni per l'uso

3.1 Sequenza di accensione

  1. Assicurarsi che tutti i collegamenti elettrici siano corretti e sicuri.
  2. Apply power to the CL86Y driver. The ALARM/PWR indicator should light up, indicating power is supplied.
  3. The motor will briefly engage and then settle, ready to receive commands.

3.2 Sending Control Signals

  • The driver accepts pulse signals from your motion controller. The pulse input frequency can be up to 200kHz.
  • The pulse width should be at least 2.5µS.
  • The direction signal determines the rotation direction of the motor.
  • The enable signal (MF) can be used to activate or deactivate the motor. When disabled, the motor will be free-spinning.

3.3 Closed Loop Operation

The integrated encoder provides real-time position feedback to the CL86Y driver. This allows the driver to detect and correct any position errors, ensuring that the motor maintains its commanded position without losing steps, even under varying loads. This results in higher accuracy and reliability compared to open-loop stepper systems.

4. Manutenzione

The STEPPERONLINE Closed Loop Stepper Motor Kit is designed for durability and requires minimal maintenance. Adhere to the following guidelines to ensure optimal performance and longevity:

  • Mantenere pulito: Regularly clean the motor and driver to prevent dust and debris accumulation, which can affect cooling and component lifespan. Use a soft, dry cloth.
  • Controllare le connessioni: Periodically inspect all wiring connections for tightness and signs of wear or corrosion. Loose connections can lead to intermittent operation or damage.
  • Condizioni ambientali: Ensure the operating environment is within the specified temperature and humidity ranges to prevent overheating or condensation.
  • Ventilazione: Ensure adequate airflow around the driver and motor, especially if they are enclosed, to dissipate heat effectively.

5. Risoluzione Dei Problemi

If you encounter issues with your STEPPERONLINE Closed Loop Stepper Motor Kit, refer to the following common problems and solutions:

  • Motor Not Moving or Erratic Movement:
    • Verify all motor and encoder wiring connections are correct and secure.
    • Controllare l'alimentazione voltage and current to ensure it meets the driver's requirements.
    • Confirm that the control signals (Pulse, Direction, Enable) from your controller are correctly connected and functioning.
    • Ensure the microstep settings on the CL86Y driver (DIP switches SW2-SW6) are configured as desired.
    • Check the ALARM/PWR indicator on the driver. If it's indicating an alarm, consult the driver's specific alarm codes (if available in the full product documentation).
  • Surriscaldamento del motore:
    • Ensure adequate ventilation around the motor and driver.
    • Verify that the motor's rated current is not being exceeded.
    • Reduce the load on the motor if possible.
  • Loss of Steps (despite closed-loop):
    • While rare in closed-loop systems, extreme loads or very high speeds can still cause issues. Ensure the motor is not operating beyond its torque or speed limits.
    • Check encoder cable integrity. Damage to the encoder cable can disrupt feedback.

If the problem persists after attempting these solutions, please contact STEPPERONLINE customer support for further assistance.

6. Specifiche

6.1 Motor Specification (34HS59-6004D-E1K-1M5)

Specifiche del motore
ParametroValore
Numero di parte del produttore34HS59-6004D-E1K-1M5
Tipo di motoreBipolar Stepper
Angolo di passo1.8 gradi
Tenendo coppia12.00Nm (1699.34oz.in)
Rated Current/phase6.0A
Resistenza di fase0.59 ohm ± 10%
Induttanza4.8mH ± 20% (1KHz)
Classe di isolamentoB 130°C [266°F]
Dimensioni del telaio86 x 86 mm
Lunghezza del corpo174mm
Diametro dell'alberoΦ14mm
Lunghezza dell'albero37mm
D-Cut Length25mm
Lunghezza del cavo1500mm
Tipo di circuito di uscitaTipo differenziale
Tipo di encoderOptical Incremental
Risoluzione dell'encoder1000PPR (4000CPR)
Volume di alimentazione dell'encodertage min4V
Volume di alimentazione dell'encodertage max5V
Encoder Output Current100mA
Encoder Output High Voltage5V
Encoder Output Low Voltage4.5V
Encoder Output Frequency Max60kHZ

6.2 Driver Specification (CL86Y)

Specifiche del driver
ParametroValore
Corrente di picco in uscita0~8.5A (0~6 RMS)
Ingresso volumetage20~80VAC / 30~110VDC (Typical 48/60VDC)
Corrente del segnale logico7~16mA (Typical 10mA)
Frequenza di ingresso degli impulsi0 ~ 200 kHz
Larghezza di impulso2.5µS
Resistenza di isolamento500 MΩ
Microstep Resolutions800 - 40000 (16 subdivisions)

7. Garanzia e supporto

7.1 Informazioni sulla garanzia

For detailed warranty information regarding your STEPPERONLINE Closed Loop Stepper Motor Kit, please refer to the product's purchase documentation or contact STEPPERONLINE customer service directly. Warranty terms typically cover manufacturing defects for a specified period from the date of purchase.

7.2 Assistenza clienti

If you require technical assistance, have questions about installation, operation, or troubleshooting that are not covered in this manual, please contact STEPPERONLINE customer support. You can often find support contact information on the official STEPPERONLINE websito o tramite il rivenditore presso il quale è stato acquistato il prodotto.

Visit the official STEPPERONLINE store for more products and support resources: STEPPERONLINE Amazon Store

© 2025 STEPPERONLINE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.