meterk ZL-R200A

Manuale di istruzioni del controller dello scaldabagno con pompa di calore ZL-R200A

Model: ZL-R200A

1. Introduzione

The ZL-R200A is a universal controller designed for air-source heat pump water heaters. It offers a multi-functional design to efficiently manage your water heating system. Key features include auxiliary heating control, water flow monitoring, ventilation pump control, antifreeze protection, sensor failure action, automatic and timed defrosting, auto-restart, exhaust temperature protection, and compressor delay/pressure protections.

ZL-R200A Controller in a bathroom setting, highlighting its multifunction design.
Figure 1: ZL-R200A Controller showcasing its multifunction design and two working modes.

2. Contenuto della confezione

Si prega di verificare che tutti gli articoli siano presenti e in buone condizioni all'apertura del pacco:

  • 1 x Mainboard
  • 1 x Display Panel
  • 4 x Temperature Sensors
Contents of the ZL-R200A package including the display panel, mainboard, sensors, and connectors.
Figure 2: ZL-R200A package contents, including the display panel, mainboard, and various sensors/connectors.

3. Specifiche

CaratteristicaSpecificazione
Intervalli di impostazioneda 10℃ a 70℃
Intervalli di visualizzazione-40℃ a 130℃
Temperatura di lavoro0-50℃
Temperatura di conservazione-10℃ a 60℃
Umidità ambientale20-85%RH (without dew)
Alimentazione elettrica220 V CA ±10%, 50/60 Hz
RisultatiCompressor 30A; Heaters 8A; Others 3A
Isteresi2~10℃
Water Sensors Calibration-9.9 ~ 9.9 ℃
Heater Energized From-5 ~ 25 ℃
Defrost Starting TimeDa 10 a 90 minuti
Defrost Starting Temperature-9~0℃
Defrost Stop Temperature2~30℃
Maximum Defrost TimeDa 2 a 15 minuti
Exhaust Protections Temperature50 ~ 125℃
Display Panel Dimensions86 x 86 mm (3.39 x 3.39 pollici)
Dimensioni scheda madre105 x 90 x 35 mm (4.13 x 3.54 x 1.39 pollici)
Peso del pacco651 g (1.44 libbre)
Dimensions of the ZL-R200A display panel and mainboard.
Figure 3: Dimensions of the ZL-R200A display panel and mainboard.
Detailed specifications table for the ZL-R200A controller.
Figure 4: Detailed specifications of the ZL-R200A controller.

4. Informazioni sulla sicurezza

  • Ensure U34 is set correctly; incorrect settings may prevent the system from functioning.
  • The internal real-time clock can maintain accuracy for up to 72 hours after a power loss.
  • All sensors must be installed in their correct and designated positions.
  • Never plug or unplug the panel bundle while power is supplied to the unit.
  • The display panel should be installed indoors only, not outdoors.

5. Configurazione e installazione

Careful installation is crucial for the proper functioning of the ZL-R200A controller. Refer to the wiring diagram below for correct connections.

Wiring Diagram for ZL-R200A controller, showing connections for display, sensors, compressor, heater, valve, fan, and pump.
Figure 5: ZL-R200A Wiring Diagram. Ensure all connections are made according to this diagram. Pay close attention to the 220VAC(N) and 220VAC(L) inputs, and the connections for the compressor, heater, valve, fan, and pump. Sensors for water, pipe, exhaust, outdoor, pressure, and flowing are also indicated.

Note di installazione:

  • Alimentazione elettrica: Connect 220VAC(N) and 220VAC(L) to the designated terminals.
  • Sensori: Connect the water, pipe, exhaust, and outdoor sensors to their respective inputs (T1, T2, T3, T4). Ensure correct polarity and secure connections.
  • Risultati: Connect the compressor, heater, valve, fan, and pump to their corresponding output terminals (K1, K2, K3, K4, K5).
  • Display: Connect the display panel to the mainboard using the provided cable. Remember, the panel must be installed indoors.
  • Pressure/Flowing Switches: Connect pressure and flowing switches if applicable to the designated terminals (HP, SM).

6. Istruzioni per l'uso

The ZL-R200A controller features an intuitive interface for easy operation.

ZL-R200A Instruction Manual V2.0 page showing display indications, key operations, and failure codes.
Figura 6: Oltreview of the ZL-R200A Instruction Manual V2.0, detailing display indications, key operations, and failure codes.

Operazioni chiave:

  • Imposta la temperatura dell'acqua:
    Premere or to adjust the water temperature. Holding the button will change the value faster. The setting will be saved automatically after 5 seconds of inactivity. The factory default setting is 40°C.
  • Selezione della modalità di lavoro:
    The controller has two working modes: "AUTO" and "SAVE".
    • "AUTO" Mode: The system will maintain the set temperature by heating as needed.
    • "SAVE" Mode: Heating will only occur within the three pre-set time periods. If the "Auto restart function" (U80) is disabled (set to 0), the controller will default to "AUTO" mode after a power supply interruption.
  • Impostazione dell'orologio:
    1. Premere il tasto M key. The hour digits will blink.
    2. Utilizzo or per impostare l'ora.
    3. Premere il tasto M key again. The minute digits will blink.
    4. Utilizzo or per impostare i minuti.
    5. Premere il tasto M key to exit the clock setting.
  • Periods Setting for "SAVE" Mode:
    1. Premere e tenere premuto il tasto M key for 3 seconds to enter the period setting status.
    2. Utilizzo or to select the desired period and toggle its on/off status.
    3. Utilizzo or to set the time value for the selected period.
    4. Premere e tenere premuto il tasto M key for 3 seconds to save the settings and exit.
  • Temperature Inquiry:
    When not in system parameter setting status, press the S key to consecutively display the temperature readings from all connected sensors. The results will be shown for 3 seconds.
  • Acceso/Spento:
    Premere e tenere premuto il tasto key for 3 seconds to switch the controller between online (operating) and offline (standby) modes.

7. Parametri di sistema

System parameters allow for advanced configuration of the controller's behavior. Exercise caution when modifying these settings.

Accessing System Parameters:

  1. Premere E keys simultaneously to enter the password input screen.
  2. Enter the password (default is "P00" if not changed) using E .
  3. Premere S to confirm. If the password is correct, you will enter the parameter set status. If incorrect, the system will exit.

Impostazione dei parametri:

  1. Premere or per selezionare un parametro.
  2. Premere S to display the current value of the selected parameter.
  3. Premere or to adjust the parameter value.
  4. Premere S to return to parameter selection.
  5. Premere e tenere premuto S for 5 seconds to save the settings and exit. If no key operation occurs for 15 seconds, the system will exit without saving.

System Parameter Table:

NO.CodiceImpostazione della funzioneAllineareIndicazionePredefinito
1Minore 01Isteresi2~10℃5
2Minore 02Water sensor calibration-9.9~9.9℃0.0
3Minore 03Heater energized from-5~25℃La temperatura esterna12
4Minore 30Orario di inizio sbrinamentoDurata: 10~90 minuti45
5Minore 31Defrost start temperature-9~0℃-5
6Minore 32Temperatura di arresto dello sbrinamento2~30℃8
7Minore 33Tempo massimo di sbrinamentoDurata: 2~15 minuti8
8Minore 34Valve working mode0~10: Heat off, defrost on
1: Heat on, defrost off
0
9Minore 50Exhaustion protection mode0~20: Disattiva la protezione
1: Protect, fan keeps
2: Proteggere, il ventilatore si ferma
1
10Minore 51Exhaustion protection temperature50~125℃110
11Minore 60High/low pressure warning mode0~20: Disabilita
1: Warning when closed
2: Avviso quando aperto
0
12Minore 61Water flowing switch mode0~20: Disabilita
1: Effective when closed
2: Efficace quando aperto
0
13Minore 65Buzzing alarming0~10: Disabilita; 1: Abilita1
14Minore 66Backlight brightness when no key operation0~10: Dim; 1: Bright0
15Minore 80Funzione di riavvio automatico0~10: Disabilita; 1: Abilita0
16Minore 81Blocco tastiera0~10: Unlocked; 1: Locked0
17Minore 90Le password00~9911

8. Manutenzione

To ensure the longevity and optimal performance of your ZL-R200A controller, follow these maintenance guidelines:

  • Pulizia: Gently wipe the display panel with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the screen or buttons.
  • Verifiche della connessione: Periodically inspect all wiring connections to the mainboard and sensors to ensure they remain secure and free from corrosion.
  • Integrità del sensore: Verify that all temperature sensors are correctly positioned and undamaged. Damaged or improperly placed sensors can lead to inaccurate readings and inefficient operation.
  • Condizioni ambientali: Ensure the display panel remains installed indoors and is not exposed to extreme temperatures, direct sunlight, or excessive humidity, as specified in the safety information.

9. Risoluzione Dei Problemi

The ZL-R200A controller is designed to display error codes to help diagnose potential issues. Refer to the table below for common failure codes and their meanings.

Failure Code Table:

NO.CodiceFallimento
1E01Water container sensor failure
2E02Pipe Coil sensor failure
3E03Exhaustion sensor failure
4E04Outdoor sensor failure
5E05Water flow warning
6E06High/low pressure input warning
7E08Errore di comunicazione
8AdFFilling refrigerant
9UnLRestore password to "11"

Passaggi generali per la risoluzione dei problemi:

  • Nessun potere: Controllare il collegamento dell'alimentazione e assicurarsi che l'interruttore automatico non sia scattato.
  • Letture di temperatura errate: Verify that all sensors are correctly installed and securely connected. Check for any physical damage to the sensor wires.
  • Sistema non riscaldante/raffreddante: Ensure the working mode is set correctly ("AUTO" or "SAVE" with appropriate periods). Check for any active error codes.
  • Problemi di visualizzazione: If the display is blank or erratic, ensure the panel cable is securely connected to the mainboard.

10. Suggerimenti per l'utente

  • Ottimizzare l'uso dell'energia: Utilize the "SAVE" working mode and configure the time periods to match your hot water demand, reducing energy consumption during off-peak hours.
  • Monitoraggio regolare: Periodically use the temperature inquiry function (S key) to check sensor readings and ensure consistent system performance.
  • Familiarize with Error Codes: Understanding the failure codes will enable quicker diagnosis and resolution of any issues that may arise. Keep this manual handy for reference.
  • Connessioni sicure: Ensure all wiring connections are tight and properly insulated to prevent electrical issues and ensure reliable operation.

11. Garanzia e supporto

This product comes with a 1-year guarantee from the date of purchase. If your purchase does not meet merchantable quality, is unfit for purpose, or does not match the description, please contact the seller for assistance.

Richiesta di garanzia:

  • For wrongly-shipped items, please contact us within 48 hours of delivery. We will arrange to deliver the correct items or process a full refund.
  • For defective or faulty products, please provide photos or videos of the issue. Upon confirmation, we will arrange for a reshipment or refund.

For any support inquiries, please refer to the contact information provided by your retailer or the official product page.