Aideepen 6133A

Manuale d'uso

Aideepen 6133A LCD Battery Capacity Indicator & Voltmeter Gauge

Modello: 6133A

1. Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of the Aideepen 6133A LCD Battery Capacity Indicator and Voltmeter Gauge. This device is designed to accurately measure and display battery capacity and voltage for various battery types, including Lead Acid, Ternary Lithium, and Lithium Iron Phosphate (LiFePO4) batteries. It features a clear LCD display, user-configurable settings, and optional waterproof protection.

2. Informazioni sulla sicurezza

  • Assicurare il volumetage detection range (DC 8V-100V) is suitable for your battery system.
  • Scollegare sempre l'alimentazione prima dell'installazione o della manutenzione per evitare scosse elettriche.
  • Observe correct polarity during wiring to prevent damage to the device and battery. The device includes reverse protection.
  • Non esporre il dispositivo alla luce solare diretta per periodi prolungati.
  • If installing a non-waterproof version, ensure it is protected from moisture.
  • Questo prodotto può esporti a sostanze chimiche, tra cui il piombo, che è noto allo Stato della California come causa di cancro e difetti alla nascita o altri danni riproduttivi. Per maggiori informazioni, vai a www.P65Warnings.ca.gov.

3. Prodotto finitoview

The Aideepen 6133A is a versatile battery monitor offering high stability, strong reliability, and a long service life. It provides a visual display of battery capacity and voltage, with easy-to-use controls for configuration.

3.1 Caratteristiche principali

  • Doppio display: Simultaneously shows battery capacity (percentage) e voltage(V).
  • Ampio volumetage Gamma: Supports DC 8V-100V (recommended use within 90V).
  • Compatibilità multi-batteria: Configurable for Lead Acid, Ternary Lithium, and Lithium Iron Phosphate (LiFePO4) batteries.
  • Memoria di spegnimento: Mantiene le impostazioni dopo un'interruzione di corrente.
  • Protezione inversa: Protezioni contro cablaggi errati.
  • Allarme di bassa pressione: User-configurable low voltage allarme.
  • Adjustable Potentiometer: For accuracy error calibration.
  • Schermo LCD: Clear display with optional backlight.
  • Optional Waterproof Design: Available in regular and waterproof styles.

3.2 Componenti

  • 6133A Battery Capacity Indicator and Voltmeter Gauge unit
  • Connection cable (with pluggable connectors)
  • Manuale di istruzioni
  • Double-sided adhesive (for some variants)
Aideepen 6133A Meter Head, Instruction Manual, and Connection Line
Figure 1: Product components (Meter head, instruction manual, connection line).
Visible details of the 6133A meter showing pluggable connectors and voltage regolazione
Figure 2: Visible details showing pluggable connectors for quick replacement and a rotation point for voltage level adjustment.

4. Specifiche

ParametroValore
Numero di modello6133A (Electricity and voltage display meter)
Voltage Intervallo di rilevamentoDC 8V-100V (Recommended use within 90V)
Corrente di lavoro≤ 15mA
Metodo di visualizzazioneLCD Screen (Digital Only)
Colore dello schermoBlue/White/Color (Optional)
Precisione di rilevamento± 1%
Frequenza di aggiornamento500ms/time (Approximately twice per second)
Hole Size (Opening Size)58.5 * 28.5 MM
Dimensions (Boundary Dimension)61.3 * 33.3 * 13.5 MM
Temperatura di esercizioda -10°C a +70°C
Umidità di lavoro10-80%
Pressione di lavoro80-106 kPa
Alimentazione elettricaDC
Batteria inclusaNO
Funzione impermeabileOptional (Available in some variants)
Product Parameters and Performance Table for 6133A Battery Detector
Figure 3: Detailed product parameters and performance indicators.
Diagramma delle dimensioni del prodotto che mostra le dimensioni di 61.3 mm, 33.3 mm e 13.5 mm
Figura 4: Dimensioni del prodotto.

5. Configurazione e installazione

Follow these steps for proper installation of your 6133A Battery Capacity Indicator and Voltmeter Gauge:

  1. Preparare la posizione di montaggio: Choose a suitable location for the display unit. Ensure the surface is flat and allows for the required hole size of 58.5mm x 28.5mm.
  2. Apertura di taglio: Carefully cut an opening of 58.5mm x 28.5mm in the chosen mounting surface.
  3. Insert Display Unit: Insert the display unit into the cut opening. The unit is designed to buckle into place for a secure fit.
  4. Cablaggio: Connect the provided wiring harness to the pluggable connectors on the back of the display unit. Ensure correct polarity (red wire for positive, black wire for negative). The device features reverse protection, but correct wiring is always recommended.
  5. Collegamento alla batteria: Connect the other end of the wiring harness to your battery system. Ensure the battery voltage rientra nell'intervallo DC 8V-100V.
  6. Cablaggio sicuro: Route and secure all wiring to prevent accidental disconnection or damage.
  7. Accensione: Once all connections are secure, power on your battery system. The display unit should light up and show the current battery capacity and voltage.
Comparison of Regular and Waterproof styles of the 6133A battery detector
Figure 5: Product image display showing regular and waterproof styles. Choose the appropriate style for your environment.

6. Istruzioni per l'uso

The 6133A features a "SET" button and a "PWR" (or power/mode) button for navigation and configuration.

Diagram showing 7 modes that can be changed at will on the 6133A battery detector
Figura 6: Oltreview of the 7 configurable modes.

Modalità di navigazione 6.1

  • Short press the "SET" button to cycle through display modes (e.g., voltage, capacity, temperature if applicable).
  • Long press the "SET" button (for 2 seconds) to enter the settings menu.
  • In settings, use the "PWR" button (bottom right) to change values or bits, and the "SET" button (top right) to confirm and save, or to shift between settings.
  • Long press the "SET" button (for 2 seconds) to exit settings and return to the main display.

6.2 Battery Type Settings (Modes 1, 2, 3)

The device supports Lead Acid (P), Ternary Lithium (L), and Iron Lithium (F) batteries. These settings are retained in power-off memory.

  1. Lead Acid Battery (Mode 1-P):
    Lead acid battery setting screen showing '1-P 12'
    Figure 7: Lead Acid Battery Setting (1-P 12 example).

    On the lead-acid battery settings page, the voltage value flashes. Short press the bottom right button (PWR) to select the desired battery voltage (e.g., 12V, 36V, 48V, 60V, 72V, 84V). After selecting the voltage, short press the top right button (SET) to confirm and save the value. Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.

  2. Ternary Lithium Battery (Mode 2-L):
    Ternary lithium battery setting screen showing '2-L 03'
    Figure 8: Ternary Lithium Battery Setting (2-L 03 example).

    On the ternary lithium-ion battery settings page, the battery string number value flashes. Short press the bottom right button (PWR) to select the desired battery string number (from L03 to L20). After selecting the string number, short press the top right button (SET) to confirm and save the value. Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.

  3. Iron Lithium Battery (Mode 3-F):
    Iron lithium battery setting screen showing '3-F 03'
    Figure 9: Iron Lithium Battery Setting (3-F 03 example).

    On the iron lithium battery settings page, the battery string number value flashes. Short press the bottom right button (PWR) to select the desired battery string number (from F03 to F23). After selecting the string number, short press the top right button (SET) to confirm and save the value. Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.

6.3 Custom High and Low Voltage Settings (Mode 4)

Vol. alto e basso personalizzatotage settings screen showing '00.0 000'
Figure 10: Custom High and Low Voltage Settings.

On this page, "00.0" on the left represents the low voltage, and "000" on the right represents the saturation voltage. (Tip: The actual value of 000 on the right is 00.0, for example, 255 shows 25.5).

  • Short press the bottom right button (PWR) to set the bit value.
  • After the bit value is set, long press the bottom right button (PWR) for 2 seconds to shift to the next bit.
  • Once both the low voltage e saturazione voltage are set, short press the top right button (SET) to confirm and save the values (all values remain lit).
  • Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.

6.4 Display Backlight Settings (Mode 5-b)

Display backlight settings screen showing '5-b On'
Figure 11: Display Backlight Settings.

On the backlight setting page, "ON/OFF" flashes.

  • Short press the bottom right button (PWR) to select ON or OFF.
  • SOPRA: The display screen automatically delays for 10 seconds before turning off.
  • OFF: The display screen remains on.
  • Short press the top right button (SET) to confirm and save the options.
  • Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.

6.5 Low Pressure Alarm Settings (Mode 6-Lo)

Low pressure alarm settings screen showing '00.0 Lo'
Figure 12: Low Pressure Alarm Settings.

On the Low Voltage Alarm Settings page, "00.0" on the left is the setting value.

  • Short press the bottom right button (PWR) to set the bit value.
  • After the bit value is set, long press the bottom right button (PWR) for 2 seconds to shift.
  • After the alarm voltage is set, short press the top right button (SET) to confirm and save the value (all values remain lit).
  • Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.

6.6 Alarm Sound Settings (Mode 7-A)

Alarm sound settings screen showing '7-A On'
Figure 13: Alarm Sound Settings.

On the alarm sound setting page, the ON/OFF button flashes.

  • Short press the bottom right button (PWR) to select ON or OFF.
  • SOPRA: Turn on the alarm sound.
  • OFF: Disattiva il suono della sveglia.
  • Short press the top right button (SET) to confirm and save the options.
  • Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.

7. Manutenzione

  • Pulizia: Utilizzare un panno morbido e asciutto per pulire il display e casing. Non utilizzare detergenti abrasivi o solventi.
  • Ispezione: Controllare periodicamente i collegamenti elettrici per verificarne la tenuta e l'eventuale presenza di segni di usura o corrosione.
  • Magazzinaggio: If storing the device for an extended period, ensure it is in a dry, cool environment, away from direct sunlight and extreme temperatures.
  • Calibrazione della precisione: The device features an adjustable potentiometer for accuracy error calibration. If you suspect inaccurate readings, this can be adjusted by a qualified technician.

8. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il display non si accendeNo power, incorrect wiring, or faulty connection.Check power source. Verify wiring polarity (red to positive, black to negative). Ensure connectors are securely plugged in.
Vol non correttotaglettura e/capacitàIncorrect battery type setting, calibration error, or battery issue.Verify the correct battery type (Lead Acid, Ternary Lithium, Iron Lithium) and string number/voltage is set in the operating modes. If persistent, consider accuracy calibration via the potentiometer. Check battery health.
Low pressure alarm not working or false alarmsAlarm settings incorrect or battery voltage fluctuating.Check and adjust the low pressure alarm settings (Mode 6-Lo). Ensure the alarm sound is enabled (Mode 7-A).
Display backlight always on/off (when not desired)Backlight setting incorrect.Adjust the display backlight settings (Mode 5-b) to ON (10-second delay) or OFF (always on).

9. Suggerimenti per l'utente

  • The compact dimensions (61.3*33.3*13.5MM) make this meter suitable for installations where space is limited.
  • The digital display provides clear and accurate readings of electricity and voltage, which is beneficial for monitoring battery status.
  • Remember to set the correct battery type and voltage/string number for accurate readings, as the device has power-off memory for these settings.

10. Garanzia e supporto

For any issues or questions not covered in this manual, please contact your retailer or the manufacturer's customer support. Keep your purchase receipt for warranty claims.

This product is intended for DIY electrical applications. Ensure you have adequate knowledge and take necessary precautions when working with electrical systems.

Documenti correlati - 6133A

Preview Manuale utente dell'indicatore di batteria Aideepen VTM100 - Vol.tage monitoraggio SOC
Manuale utente completo per l'indicatore di batteria Aideepen VTM100. Scopri come monitorare la tensione CCtage, stato di carica (SOC) e temperatura per varie tipologie di batterie, come piombo-acido, litio ternario e LiFePO4.
Preview Manuale di istruzioni del rilevatore di quantità elettrica 6133A
Instruction manual for the 6133A electric quantity detector, detailing product parameters, performance indicators, product description, and model specifications for various battery types.
Preview TS457 VoltagManuale utente del tester di resistenza interna
Comprehensive user manual for the Aideepen TS457 Voltage Internal Resistance Tester. This guide details technical specifications, interface functions, power supply methods, testing procedures using Kelvin clamps and battery test stands, and various setting configurations for accurate DC voltage and internal resistance measurements.
Preview U-18 USB Voltage e Manuale dell'utente di Current Tester
Manuale utente completo per Aideepen U-18 USB Voltage Current Tester. Scopri le sue caratteristiche, le precauzioni di sicurezza, il funzionamento dell'interfaccia, le specifiche tecniche, i test del protocollo di ricarica rapida (QC, PD) e il software per PC per un'analisi dettagliata.
Preview Tester multifunzione Aideepen LCR-TC1: caratteristiche, specifiche e guida all'uso
Guida completa al tester multifunzione Aideepen LCR-TC1, che descrive in dettaglio le sue caratteristiche, i parametri prestazionali, le capacità di test dei componenti (transistor, diodi, resistori, condensatori, induttori), la decodifica IR e la risoluzione dei problemi. Scopri come utilizzare questo versatile analizzatore di componenti elettronici.
Preview Modulo convertitore boost DC-DC Aideepen da 1200 W e 20 A: specifiche e guida
Specifiche dettagliate, guida all'uso e risoluzione dei problemi per il modulo convertitore boost CC-CC Aideepen 1200W 20A, un vol regolabiletagModulo di alimentazione funzionante da 8-60 V a 12-83 V.