1. Introduzione
This manual provides detailed instructions for the installation, operation, and maintenance of the Aideepen 6133A LCD Battery Capacity Indicator and Voltmeter Gauge. This device is designed to accurately measure and display battery capacity and voltage for various battery types, including Lead Acid, Ternary Lithium, and Lithium Iron Phosphate (LiFePO4) batteries. It features a clear LCD display, user-configurable settings, and optional waterproof protection.
2. Informazioni sulla sicurezza
- Assicurare il volumetage detection range (DC 8V-100V) is suitable for your battery system.
- Scollegare sempre l'alimentazione prima dell'installazione o della manutenzione per evitare scosse elettriche.
- Observe correct polarity during wiring to prevent damage to the device and battery. The device includes reverse protection.
- Non esporre il dispositivo alla luce solare diretta per periodi prolungati.
- If installing a non-waterproof version, ensure it is protected from moisture.
- Questo prodotto può esporti a sostanze chimiche, tra cui il piombo, che è noto allo Stato della California come causa di cancro e difetti alla nascita o altri danni riproduttivi. Per maggiori informazioni, vai a www.P65Warnings.ca.gov.
3. Prodotto finitoview
The Aideepen 6133A is a versatile battery monitor offering high stability, strong reliability, and a long service life. It provides a visual display of battery capacity and voltage, with easy-to-use controls for configuration.
3.1 Caratteristiche principali
- Doppio display: Simultaneously shows battery capacity (percentage) e voltage(V).
- Ampio volumetage Gamma: Supports DC 8V-100V (recommended use within 90V).
- Compatibilità multi-batteria: Configurable for Lead Acid, Ternary Lithium, and Lithium Iron Phosphate (LiFePO4) batteries.
- Memoria di spegnimento: Mantiene le impostazioni dopo un'interruzione di corrente.
- Protezione inversa: Protezioni contro cablaggi errati.
- Allarme di bassa pressione: User-configurable low voltage allarme.
- Adjustable Potentiometer: For accuracy error calibration.
- Schermo LCD: Clear display with optional backlight.
- Optional Waterproof Design: Available in regular and waterproof styles.
3.2 Componenti
- 6133A Battery Capacity Indicator and Voltmeter Gauge unit
- Connection cable (with pluggable connectors)
- Manuale di istruzioni
- Double-sided adhesive (for some variants)


4. Specifiche
| Parametro | Valore |
|---|---|
| Numero di modello | 6133A (Electricity and voltage display meter) |
| Voltage Intervallo di rilevamento | DC 8V-100V (Recommended use within 90V) |
| Corrente di lavoro | ≤ 15mA |
| Metodo di visualizzazione | LCD Screen (Digital Only) |
| Colore dello schermo | Blue/White/Color (Optional) |
| Precisione di rilevamento | ± 1% |
| Frequenza di aggiornamento | 500ms/time (Approximately twice per second) |
| Hole Size (Opening Size) | 58.5 * 28.5 MM |
| Dimensions (Boundary Dimension) | 61.3 * 33.3 * 13.5 MM |
| Temperatura di esercizio | da -10°C a +70°C |
| Umidità di lavoro | 10-80% |
| Pressione di lavoro | 80-106 kPa |
| Alimentazione elettrica | DC |
| Batteria inclusa | NO |
| Funzione impermeabile | Optional (Available in some variants) |


5. Configurazione e installazione
Follow these steps for proper installation of your 6133A Battery Capacity Indicator and Voltmeter Gauge:
- Preparare la posizione di montaggio: Choose a suitable location for the display unit. Ensure the surface is flat and allows for the required hole size of 58.5mm x 28.5mm.
- Apertura di taglio: Carefully cut an opening of 58.5mm x 28.5mm in the chosen mounting surface.
- Insert Display Unit: Insert the display unit into the cut opening. The unit is designed to buckle into place for a secure fit.
- Cablaggio: Connect the provided wiring harness to the pluggable connectors on the back of the display unit. Ensure correct polarity (red wire for positive, black wire for negative). The device features reverse protection, but correct wiring is always recommended.
- Collegamento alla batteria: Connect the other end of the wiring harness to your battery system. Ensure the battery voltage rientra nell'intervallo DC 8V-100V.
- Cablaggio sicuro: Route and secure all wiring to prevent accidental disconnection or damage.
- Accensione: Once all connections are secure, power on your battery system. The display unit should light up and show the current battery capacity and voltage.

6. Istruzioni per l'uso
The 6133A features a "SET" button and a "PWR" (or power/mode) button for navigation and configuration.

Modalità di navigazione 6.1
- Short press the "SET" button to cycle through display modes (e.g., voltage, capacity, temperature if applicable).
- Long press the "SET" button (for 2 seconds) to enter the settings menu.
- In settings, use the "PWR" button (bottom right) to change values or bits, and the "SET" button (top right) to confirm and save, or to shift between settings.
- Long press the "SET" button (for 2 seconds) to exit settings and return to the main display.
6.2 Battery Type Settings (Modes 1, 2, 3)
The device supports Lead Acid (P), Ternary Lithium (L), and Iron Lithium (F) batteries. These settings are retained in power-off memory.
- Lead Acid Battery (Mode 1-P):

Figure 7: Lead Acid Battery Setting (1-P 12 example). On the lead-acid battery settings page, the voltage value flashes. Short press the bottom right button (PWR) to select the desired battery voltage (e.g., 12V, 36V, 48V, 60V, 72V, 84V). After selecting the voltage, short press the top right button (SET) to confirm and save the value. Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.
- Ternary Lithium Battery (Mode 2-L):

Figure 8: Ternary Lithium Battery Setting (2-L 03 example). On the ternary lithium-ion battery settings page, the battery string number value flashes. Short press the bottom right button (PWR) to select the desired battery string number (from L03 to L20). After selecting the string number, short press the top right button (SET) to confirm and save the value. Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.
- Iron Lithium Battery (Mode 3-F):

Figure 9: Iron Lithium Battery Setting (3-F 03 example). On the iron lithium battery settings page, the battery string number value flashes. Short press the bottom right button (PWR) to select the desired battery string number (from F03 to F23). After selecting the string number, short press the top right button (SET) to confirm and save the value. Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.
6.3 Custom High and Low Voltage Settings (Mode 4)

On this page, "00.0" on the left represents the low voltage, and "000" on the right represents the saturation voltage. (Tip: The actual value of 000 on the right is 00.0, for example, 255 shows 25.5).
- Short press the bottom right button (PWR) to set the bit value.
- After the bit value is set, long press the bottom right button (PWR) for 2 seconds to shift to the next bit.
- Once both the low voltage e saturazione voltage are set, short press the top right button (SET) to confirm and save the values (all values remain lit).
- Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.
6.4 Display Backlight Settings (Mode 5-b)

On the backlight setting page, "ON/OFF" flashes.
- Short press the bottom right button (PWR) to select ON or OFF.
- SOPRA: The display screen automatically delays for 10 seconds before turning off.
- OFF: The display screen remains on.
- Short press the top right button (SET) to confirm and save the options.
- Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.
6.5 Low Pressure Alarm Settings (Mode 6-Lo)

On the Low Voltage Alarm Settings page, "00.0" on the left is the setting value.
- Short press the bottom right button (PWR) to set the bit value.
- After the bit value is set, long press the bottom right button (PWR) for 2 seconds to shift.
- After the alarm voltage is set, short press the top right button (SET) to confirm and save the value (all values remain lit).
- Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.
6.6 Alarm Sound Settings (Mode 7-A)

On the alarm sound setting page, the ON/OFF button flashes.
- Short press the bottom right button (PWR) to select ON or OFF.
- SOPRA: Turn on the alarm sound.
- OFF: Disattiva il suono della sveglia.
- Short press the top right button (SET) to confirm and save the options.
- Long press the top right button (SET) for 2 seconds to return to the main page, or short press it to set other modes.
7. Manutenzione
- Pulizia: Utilizzare un panno morbido e asciutto per pulire il display e casing. Non utilizzare detergenti abrasivi o solventi.
- Ispezione: Controllare periodicamente i collegamenti elettrici per verificarne la tenuta e l'eventuale presenza di segni di usura o corrosione.
- Magazzinaggio: If storing the device for an extended period, ensure it is in a dry, cool environment, away from direct sunlight and extreme temperatures.
- Calibrazione della precisione: The device features an adjustable potentiometer for accuracy error calibration. If you suspect inaccurate readings, this can be adjusted by a qualified technician.
8. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il display non si accende | No power, incorrect wiring, or faulty connection. | Check power source. Verify wiring polarity (red to positive, black to negative). Ensure connectors are securely plugged in. |
| Vol non correttotaglettura e/capacità | Incorrect battery type setting, calibration error, or battery issue. | Verify the correct battery type (Lead Acid, Ternary Lithium, Iron Lithium) and string number/voltage is set in the operating modes. If persistent, consider accuracy calibration via the potentiometer. Check battery health. |
| Low pressure alarm not working or false alarms | Alarm settings incorrect or battery voltage fluctuating. | Check and adjust the low pressure alarm settings (Mode 6-Lo). Ensure the alarm sound is enabled (Mode 7-A). |
| Display backlight always on/off (when not desired) | Backlight setting incorrect. | Adjust the display backlight settings (Mode 5-b) to ON (10-second delay) or OFF (always on). |
9. Suggerimenti per l'utente
- The compact dimensions (61.3*33.3*13.5MM) make this meter suitable for installations where space is limited.
- The digital display provides clear and accurate readings of electricity and voltage, which is beneficial for monitoring battery status.
- Remember to set the correct battery type and voltage/string number for accurate readings, as the device has power-off memory for these settings.
10. Garanzia e supporto
For any issues or questions not covered in this manual, please contact your retailer or the manufacturer's customer support. Keep your purchase receipt for warranty claims.
This product is intended for DIY electrical applications. Ensure you have adequate knowledge and take necessary precautions when working with electrical systems.