Concord MC-880

Manuale utente del controller del compressore d'aria a vite Concord MC-880

Model: MC-880 | Brand: Concord

1. Introduzione

Welcome to the user manual for the Concord MC-880 Screw Air Compressor Controller. This robust display panel is designed for efficient and reliable control of screw air compressors. This manual provides essential information for proper installation, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your controller.

2. Prodotto finitoview

The MC-880 controller features a clear display and intuitive button interface for managing your air compressor. It is designed for integration into industrial electrical systems.

2.1 Pannello frontale

The front panel includes a digital display, along with several control buttons:

  • I (Green): Start/Power On
  • O (Red): Stop/Power Off
  • S: Set/Enter
  • C: Cancel/Clear
  • (Up Arrow): Navigate Up/Increase Value
  • (Down Arrow): Navigate Down/Decrease Value
Davanti view of the Concord MC-880 air compressor controller, showing the display and control buttons.
Figura 2.1: Fronte view of the MC-880 Controller

2.2 Pannello posteriore

The back panel houses the electrical connections and a product label detailing model specifics.

Indietro view of the Concord MC-880 controller, showing the product label with model, voltage, and power details.
Figura 2.2: Indietro view of the MC-880 Controller with product label

2.3 Video del prodottoview

Guarda questo breve video per una panoramica visivaview del prodotto.

Video 2.3: General product overview del controllore.

3. Specifiche

CaratteristicaDettaglio
ModelloMC-880 (Variants: V100, V40)
MarcaConcordia
OrigineCina continentale
Categoria Forniture Fai da TeElettrico
Voltage220 V CA
FrequenzaFrequenza 50/60 Hz
Consumo energetico5W
Lunghezza22 centimetri
Larghezza22 centimetri
Altezza11 centimetri
Peso1.0 kg

Nota: Always verify the specific model variant (e.g., V100 or V40) and its corresponding voltage requirements as indicated on the product label before installation.

Indietro view of two MC-880 controllers, showing labels for V100 and V40 variants with their respective specifications.
Figure 3.1: MC-880 Controller variants (V100 and V40) with specification labels

4. Impostazione

Safety First: Ensure all power to the air compressor system is disconnected before beginning installation. Only qualified personnel should perform electrical installation.

4.1 Montaggio

  1. Select a suitable panel location for mounting the controller, ensuring adequate ventilation and protection from moisture and excessive heat.
  2. Cut an opening in the panel according to the controller's dimensions, allowing for a snug fit.
  3. Secure the controller into the panel using appropriate fasteners (screws, clips) through the mounting holes.

4.2 Cablaggio

  1. Refer to the wiring diagram provided with your air compressor system and the specific terminal markings on the back of the MC-880 controller.
  2. Connect the power supply (220V AC, 50/60Hz) to the designated power input terminals.
  3. Connect control signals for the air compressor (e.g., motor start/stop, pressure sensors, emergency stop) to the corresponding input/output terminals on the controller.
  4. Ensure all connections are secure and properly insulated. Double-check all wiring against the system's electrical schematics.

4.3 Accensione iniziale

  1. After all connections are verified, restore power to the air compressor system.
  2. The controller display should illuminate. If not, check power connections and fuses.
  3. Perform initial configuration as required by your air compressor system's specific needs.

5. Istruzioni per l'uso

5.1 Accensione/spegnimento

  • To power on the compressor, press the green I pulsante.
  • To power off the compressor, press the red O pulsante.

5.2 Accesso alle Impostazioni

  • Premere il tasto S pulsante per accedere al menu delle impostazioni.
  • Utilizzare il (Su) e (Down) arrow buttons to navigate through menu options or adjust values.
  • Premere S again to confirm a selection or save a value.
  • Premere il tasto C button to exit a menu or cancel an operation without saving changes.

5.3 Monitoraggio

  • The display will typically show real-time operational parameters such as pressure, temperature, or operating status.
  • Use the arrow buttons to cycle through different display modes or monitored values if available.

5.4 Arresto di emergenza

In case of an emergency, immediately press the main emergency stop button on your air compressor system, which should also cut power to the controller.

6. Manutenzione

6.1 Pulizia regolare

  • Keep the controller's display and buttons clean and free from dust, dirt, and moisture.
  • Per la pulizia, utilizzare un panno morbido e asciutto. Evitare detergenti abrasivi o solventi.

6.2 Ispezione visiva

  • Ispezionare periodicamente il controller per verificare la presenza di eventuali segni di danni fisici, collegamenti allentati o corrosione.
  • Ensure all cables are securely connected and not frayed.

6.3 Condizioni ambientali

Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage to the electronic components.

6.4 Aggiornamenti firmware

Consult your air compressor manufacturer for information on potential firmware updates for the controller.

7. Risoluzione Dei Problemi

7.1 Controller Not Powering On

  • Check the main power supply to the air compressor system.
  • Verify the power connections to the controller are secure and correctly wired.
  • Inspect for any blown fuses in the control circuit.

7.2 Display Not Working/Blank

  • Assicurarsi che il controller sia alimentato.
  • Try cycling the power to the unit.
  • Se il problema persiste, contattare l'assistenza.

7.3 Il compressore non si avvia

  • Check if the controller is in an "OFF" state (red O button pressed).
  • Verify all safety interlocks on the air compressor are satisfied (e.g., pressure switches, thermal overload).
  • Check for any error messages on the controller display and refer to your air compressor's specific manual for error code interpretations.

7.4 Letture errate

  • Ensure all sensors connected to the controller are properly installed and calibrated.
  • Check sensor wiring for damage or loose connections.

For complex issues, consult a qualified technician or contact product support.

8. Suggerimenti per l'utente

  • Voltage Verifica: Ricontrolla sempre il voltage requirements on the back label of your specific MC-880 unit (e.g., V100 or V40) to ensure compatibility with your power supply.
  • Documentazione: Keep this manual and your air compressor's specific documentation handy for quick reference during operation or troubleshooting.
  • Ambiente pulito: Maintaining a clean and dry environment around the controller can significantly extend its lifespan and prevent malfunctions.

9. Garanzia e supporto

For technical assistance, questions about the product, or large quantity orders, please contact the seller directly:

Documenti correlati - Modello MC-880

Preview Guida rapida al pannello solare Concord QC5528 per telecamere a batteria Wi-Fi
Guida rapida per il pannello solare Concord QC5528, progettato per alimentare telecamere Wi-Fi a batteria. Scopri come installare, posizionare e collegare il pannello solare per prestazioni ottimali.
Preview Manuale di assistenza per la caldaia a gas 97G2UHV
Manuale di assistenza completo per la caldaia a gas 97G2UHV, che descrive in dettaglio le specifiche tecniche, l'installazione, il funzionamento, la manutenzione e la risoluzione dei problemi.
Preview Guida rapida all'installazione e alla configurazione del Concord Wireless Battery NVR
Inizia a utilizzare il tuo sistema NVR wireless a batteria Concord. Questa guida rapida fornisce informazioni essenziali su configurazione, collegamento delle telecamere, creazione di password e configurazioni di base per il tuo sistema di sorveglianza.
Preview Guida rapida all'avvio di Concord NVR
Una guida rapida per configurare e collegare il sistema Concord Network Video Recorder (NVR), incluso il collegamento di telecamere, monitor e alimentazione.
Preview Manuale utente NVR Concord CNK8845P-A: Guida all'installazione e al funzionamento
Manuale utente completo per il sistema di videosorveglianza di rete NVR ad altissima definizione Concord CNK8845P-A. Informazioni su installazione, configurazione, accesso remoto e risoluzione dei problemi.
Preview Guida rapida alla videocamera Wi-Fi alimentata a batteria Concord QC3910
Una guida rapida per la telecamera Wi-Fi alimentata a batteria Concord QC3910, che illustra la configurazione, l'installazione e gli indicatori di stato LED.