1. Introduzione
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Daikin BRC944 Series Line Controller Display Panel. Please read this manual thoroughly before using the product and keep it for future reference.
The Daikin BRC944 series are advanced line controller display panels designed for commercial air conditioning systems, offering intuitive control over various functions.

2. Configurazione e installazione
The Daikin BRC944 series line controller is designed for professional installation. Ensure all power to the air conditioning unit is disconnected before beginning installation.
2.1 Contenuto della confezione
Verificare che tutti i componenti siano presenti nella confezione:
- Daikin BRC944 Series Display Panel
- Cavi di collegamento
- Viti di montaggio
- Accessory Box (may contain additional connectors or components)
- Manuale dell'utente (questo documento)

2.2 Montaggio del pannello
- Choose a suitable indoor location for the panel, away from direct sunlight, heat sources, and areas with high humidity.
- Ensure there is sufficient space for wiring access behind the panel.
- Secure the mounting bracket (if separate) to the wall using the provided screws.
- Attach the display panel to the mounting bracket.
2.3 Collegamenti di cablaggio
Connect the display panel to the indoor unit of the air conditioning system using the provided communication cables. Refer to the wiring diagram specific to your air conditioning unit model for correct terminal connections. Improper wiring can damage the unit or the controller.

Warning: All wiring must be performed by a qualified technician in accordance with local electrical codes and regulations.
3. Istruzioni per l'uso
The BRC944 series offers intuitive control over your Daikin air conditioning system. The following describes common functions based on the BRC944B1C panel layout.

3.1 Controlli di base
- Pulsante ON/OFF: Premere per accendere o spegnere l'unità di aria condizionata.
- Pulsante MODE: Passa attraverso le modalità di funzionamento (ad esempio, Raffreddamento, Riscaldamento, Ventilatore, Deumidificazione, Auto).
- Pulsante VENTOLA: Regola la velocità della ventola (ad esempio, Bassa, Media, Alta, Auto).
- UP/DOWN Buttons (TEMP): Regola l'impostazione della temperatura desiderata.
- Pulsante IMPOSTA: Used to confirm selections in menu or timer settings.
- Pulsante TIMER: Accesses the timer settings for scheduled operation.
3.2 Setting the Timer (BRC944B1C Example)
The BRC944B1C panel includes a diagram for setting the timer. Follow these steps:
- One-Time Timer:
- Premere il pulsante TIMER.
- Use UP/DOWN to set the desired ON or OFF time.
- Premere SET per confermare.
- Timer giornaliero:
- Press the TIMER button repeatedly until 'DAILY TIMER' is selected.
- Use UP/DOWN to set the desired ON or OFF time.
- Premere SET per confermare.
The display will show the active timer settings. To cancel a timer, navigate to the timer setting and press the TIMER button until the timer indicator disappears or select 'CANCEL' if available.
4. Manutenzione
Regular maintenance ensures optimal performance and longevity of your display panel.
- Pulizia: Wipe the display panel surface with a soft, dry cloth. For stubborn dirt, use a slightly damp cloth with mild detergent, then wipe dry. Do not use abrasive cleaners, solvents, or chemical sprays directly on the panel.
- Evitare l'umidità: Keep the panel dry and away from water or excessive humidity.
- Ispezione: Periodically check the panel for any physical damage or loose connections.
Caution: Do not attempt to open the display panel housing. Refer all internal servicing to qualified personnel.
5. Risoluzione Dei Problemi
If you encounter issues with your display panel, try the following basic troubleshooting steps:
- Panel is unresponsive/blank display:
- Controllare se l'unità di aria condizionata è alimentata.
- Assicurarsi che tutti i collegamenti elettrici siano sicuri.
- Try cycling the power to the air conditioning unit (turn off at the breaker for a few minutes, then turn back on).
- Letture di temperatura errate:
- Ensure the panel is not exposed to direct heat sources or drafts that could affect its internal temperature sensor.
- I pulsanti non rispondono:
- Gently clean the button area to remove any dust or debris.
If the problem persists after attempting these steps, contact a qualified service technician.
6. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Numeri di modello | BRC944C1C, BRC944B1C, BRC944A1C |
| Tipo | Montaggio dell'aria condizionata / Parti del condizionatore d'aria |
| Applicazione | Commerciale |
| Certificazione | CE |
| Origine | Cina continentale |
| Dimensioni imballo (L x P x A) | Dimensioni: 18 cm x 18 cm x 6 cm |
| Peso del pacco | 1.0 kg |
7. Suggerimenti per l'utente
- For optimal energy efficiency, set your desired temperature and allow the system to maintain it rather than frequently adjusting.
- Familiarize yourself with the different operation modes (Cool, Heat, Fan, Dry) to select the most appropriate one for current conditions.
- Utilize the timer function to pre-cool or pre-heat your space before arrival, saving energy and enhancing comfort.
8. Garanzia e supporto
For warranty information, technical support, or service requests, please contact your original point of purchase or an authorized Daikin service center. Keep your purchase receipt and product model information handy when contacting support.