1. Introduzione
The WISRETEC Digital Display Torque Meter is a high-precision electronic device designed for accurate torque measurement. It converts any standard ratchet wrench into a digital torque wrench, offering convenience and versatility for various applications. Featuring a large screen display, multiple measurement units, and an alarm system, it ensures precise and reliable torque application.
2. Contenuto della confezione
Please check the contents of your package upon receipt. Depending on the specific model purchased, your package may include:
- Digital Torque Meter Unit
- Factory Accuracy Correction Report
- Manuale operativo
- AAA Batteries (1 pair)
- Adapters (for 'S' models, e.g., 1/2" to 3/8" square head, 1/2" to 1/4" square head)
- Scatola di imballaggio


3. Prodotto finitoview
The torque meter features a clear digital display and intuitive button controls for easy operation. It is designed to be compact and durable for various working environments.
3.1 Componenti e display

- Wrench Connection Hole: For attaching to a ratchet wrench.
- Luci LED: Red, Yellow, Green indicators for alarm.
- Pulsante '+': Aumenta il valore.
- Pulsante '-': Diminuire il valore.
- Pulsante 'M': Save/select preset torque group.
- 'P/T' Button: Short press to switch between Peak (P) and Track (T) modes. Long press to toggle buzzer on/off.
- Pulsante 'U': Short press to switch torque units. Long press to toggle backlight on/off.
- Pulsante 'C': Short press to power on/off, return, or clear.
- Area di visualizzazione: Shows Power, P/T mode, Preset Group (P#), Storage Torque, Torque Indicator, and Torque Unit (N.m, lb.ft, lb.in, kg.m, kg.cm).
4. Impostazione
4.1 Installazione della batteria
- Locate the battery compartment on the back of the torque meter.
- Aprire il coperchio della batteria.
- Inserire due batterie AAA, garantendo la corretta polarità.
- Chiudere bene il coperchio della batteria.
4.2 Attaching to a Wrench
The digital torque meter is designed to be used with a standard ratchet wrench. Simply insert the square drive of the torque meter into the corresponding socket of your ratchet wrench. Ensure a secure connection.

5. Istruzioni per l'uso
5.1 Funzionamento di base
- Accensione: Short press the 'C' button to turn on the device.
- Retroilluminazione accesa/spenta: Long press the 'U' button to toggle the display backlight. This is useful in dimly lit environments.
- Cambio unità: Short press the 'U' button to cycle through available torque units: N.m, lb.ft, lb.in, kg.m, kg.cm.
- Mode Switching (Peak/Track): Short press the 'P/T' button to switch between Peak (P) mode and Track (T) mode.
- Cicalino attivato/disattivato: Long press the 'P/T' button to enable or disable the buzzer.
5.2 Preset Torque Function (Peak Mode)
In Peak (P) mode, you can preset up to 10 different torque values (P0-P9) to meet various bolt and torque requirements. Use the '+' and '-' buttons to adjust the preset torque value.

Sistema di allarme 5.3
The device provides visual and audible alarms as you approach the preset torque value:
- 80% of Preset Torque: The orange LED light flashes, and the buzzer emits a warning sound.
- 90% of Preset Torque: The green LED light flashes, and the buzzer sound becomes more frequent.
- 100% of Preset Torque: All three LED lights (Red, Yellow, Green) flash simultaneously, and the buzzer emits a continuous, urgent sound.

5.4 Conservazione dei dati
The torque meter can store up to 500 peak torque records in its memory. These records can be queried and selectively deleted at any time.
5.5 Video didattico
6. Manutenzione
- Pulizia: Pulire il dispositivo con un panno morbido e asciutto. Non utilizzare detergenti abrasivi o solventi.
- Sostituzione della batteria: Sostituire le batterie quando sul display compare l'indicatore di batteria scarica. Rimuovere le batterie se il dispositivo non verrà utilizzato per un periodo prolungato per evitare perdite.
- Magazzinaggio: Store the torque meter in its original packing box in a dry place, away from direct sunlight and extreme temperatures. Recommended operating temperature is -20°C to 70°C, and use humidity is 15-90%.
- Calibrazione: For sustained accuracy, periodic calibration by a qualified technician is recommended.
7. Risoluzione Dei Problemi
If you encounter any issues with your WISRETEC Digital Display Torque Meter, please consider the following:
- Il dispositivo non si accende: Assicurarsi che le batterie siano installate correttamente e completamente cariche. Sostituirle con batterie nuove se necessario.
- Letture imprecise: Check that the torque meter is securely attached to the wrench. Ensure the correct unit is selected. If issues persist, the device may require recalibration.
- Problemi di visualizzazione: If the display is dim, try toggling the backlight using a long press of the 'U' button. If the display is blank, check batteries.
- Il cicalino non funziona: Check if the buzzer is disabled by long-pressing the 'P/T' button.
Per ulteriore assistenza, contattare l'assistenza clienti.
8. Specifiche
The following tables detail the specifications for various models of the WISRETEC Digital Display Torque Meter.
8.1 Models ADQ2-010 to ADQ4-340

| Caratteristica | ADQ2-010 | ADQ2-030 | ADQ3-060 | ADQ3-100 | ADQ3-135 | ADQ4-200 | ADQ4-340 |
|---|---|---|---|---|---|---|---|
| Archiviazione dei dati | 500 pezzi) | ||||||
| Precisione | CW:2%, CCW:2.5% | ||||||
| Risoluzione | 0.1 N·m, 0.1 ft·lb, 0.1 in·lb, 0.1 kg·cm, 0.01 kg·m | ||||||
| Display range (N·m) | 0.1-10 | 0.3-30 | 0.6-60 | 1-100 | 1.35-135 | 2-200 | 3.4-340 |
| Gamma di allarme | 0.5-10 | 1.5-30 | 3-60 | 5-100 | 6.7-135 | 10-200 | 17-340 |
| Precision warranty scope | 20%-100% (maximum range) | ||||||
| Dimensioni del connettore | 1/4" | 3/8" | 1/2" | ||||
| Modalità di lavoro | Peak p / Tracking t | ||||||
| Torque unit | Nm, lb.ft, lb.in, kg.m, kg.cm | ||||||
| Body length/width/height (mm) | 75*47*44mm | ||||||
| Peso corporeo (kg) | 0.16 | 0.16 | 0.17 | 0.17 | 0.19 | 0.19 | 0.19 |
| Packing box size (mm) | Dimensioni: 120*76*60 | ||||||
| Peso dell'imballaggio (kg) | 0.26 | 0.26 | 0.28 | 0.28 | 0.3 | 0.3 | 0.3 |
| Batteria | AAA*2 pezzi | ||||||
| Pulsante | 6 | ||||||
| Temperatura di esercizio | -20°C~70°C | ||||||
| Usa l'umidità | 15-90% | ||||||
| Tempo di spegnimento automatico | 90S | ||||||
8.2 Models ADQ6-600 to ADQ10-2000

| Caratteristica | ADQ6-600 | ADQ8-1000 | ADQ9-1000 | ADQ10-1500 | ADQ10-2000 |
|---|---|---|---|---|---|
| Archiviazione dei dati | 500 pezzi) | ||||
| Precisione | CW:2%, CCW:2.5% | ||||
| Risoluzione | 0.1 N·m, 0.1 ft·lb, 1 in·lb, 1 kg·cm, 0.01 kg·m | ||||
| Display range (N·m) | 6-600 | 10-1000 | 10-1000 | 15-1500 | 20-2000 |
| Gamma di allarme | 30-600 | 50-1000 | 50-1000 | 75-1500 | 100-2000 |
| Precision warranty scope | 20%-100% (maximum range) | ||||
| Dimensioni del connettore | 3/4" | 1" | |||
| Modalità di lavoro | Peak p / Tracking t | ||||
| Torque unit | Nm, lb.ft, lb.in, kg.m, kg.cm | ||||
| Body length/width/height (mm) | Dimensioni: 100*73*58 | Dimensioni: 100*73*58 | |||
| Peso corporeo (kg) | 0.76 | 0.71 | |||
| Packing box size (mm) | Dimensioni: 175*105*95 | ||||
| Peso dell'imballaggio (kg) | 1.01 | 0.95 | |||
| Batteria | AA * 2 PZ | ||||
| Pulsante | 6 | ||||
| Temperatura di esercizio | -20°C~70°C | ||||
| Usa l'umidità | 15-90% | ||||
| Tempo di spegnimento automatico | 90S | ||||