1. Introduzione
This manual provides detailed instructions for the safe and effective use of the LUTRON CL-2006 Residual Oxygen Detector Chlorine Analyzer Tester. Please read this manual thoroughly before operating the device and keep it for future reference.
Prodotto finitoview
The LUTRON CL-2006 is a precision instrument designed for the detection of residual chlorine content. It features a clear LCD display and is suitable for various applications requiring accurate chlorine measurement. It also functions as a residual oxygen detector.



2. Contenuto della confezione
Upon unpacking, please verify that all items listed below are present and in good condition. If any items are missing or damaged, contact your supplier immediately.

- LUTRON CL-2006 Chlorine Meter
- Certificato di calibrazione
- Sample Bottles (with red caps)
- Panno per la pulizia
- Manuale di istruzioni (questo documento)
- Custodia per il trasporto
Nota: Shipping regulations may prohibit the inclusion of liquids, powders, and dry batteries. Please check your local regulations and product packaging for exact contents.
3. Specifiche
| Caratteristica | Dettagli | |
|---|---|---|
| Monitor | Display LCD da 41 x 34 mm | |
| Free Residual Chlorine | Total Residual Chlorine | |
| Campo di misura | 0.00~3.50ppm (mg/L) | 0.00~3.50ppm (mg/L) |
| Potere di risoluzione | 0.01 ppm | 0.01 ppm |
| Precisione | ±0.02 ppm a 1.00 ppm | ±0.02 ppm a 1.00 ppm |
| Temperatura ambiente di esercizio | da 0 a 50℃ (da 32 a 122℉) | |
| Umidità dell'ambiente operativo | Meno dell'85% di umidità relativa | |
| Sampling tempo | Circa 1 secondo | |
| Alimentazione elettrica funzionante | 1.5V (AAA) No. 3 battery * 6 | |
| Peso | 320g/0.70lb (including battery) | |
| Misurare | 155 x 76 x 62 mm (6.1 x 3.0 x 2.4 pollici) | |
Caratteristiche aggiuntive:
- Light source: Light emitting diode, wavelength 525nm
- Light source detection: Photocell
- Sampling capacity: 10mL
- Records maximum value, minimum value, and reading lock function.
4. Configurazione e installazione della batteria
Installazione della batteria
The LUTRON CL-2006 requires six 1.5V (AAA) No. 3 batteries for operation. Ensure correct polarity when inserting batteries.
- Individuare il vano batteria sul retro del dispositivo.
- Aprire il coperchio del vano batterie.
- Insert six 1.5V (AAA) batteries, observing the polarity markings (+/-).
- Chiudere saldamente il coperchio del vano batterie.
Nota: Se il misuratore non viene utilizzato per un periodo prolungato, rimuovere le batterie per evitare perdite e danni.
5. Funzionamento
Procedura di misurazione di base
- Accensione: Press the "POWER" button to turn on the device. The LCD display will illuminate.
- Sampla Preparazione: Collect a 10mL sample of the water to be tested into one of the provided sample bottiglie.
- Aggiunta del reagente: Add the appropriate reagent for Free Residual Chlorine or Total Residual Chlorine measurement to the sample. Follow the reagent manufacturer's instructions for dosage and mixing.
- Inserisci Sampon: Posizionare il preparato sample bottle into the meter's sampla camera.
- Avvia misurazione: Press the "TEST" button to begin the measurement. The device will take approximately 1 second to sample and display the reading.
- Leggi valore: The residual chlorine content (in ppm or mg/L) will be displayed on the 41 x 34mm LCD screen.
Funzioni avanzate
- Funzione HOLD: Premere il pulsante "HOLD" per bloccare la lettura corrente sul display. Premere nuovamente per rilasciare.
- Registrazione MAX/MIN: The device can record the maximum and minimum values measured. Refer to the full instruction manual for detailed steps on accessing and clearing these records.
- Calibrazione ZERO: For accurate measurements, perform a ZERO calibration as needed. This typically involves using a blank sample (distilled water) and following the calibration procedure outlined in the full manual.
6. Manutenzione e cura
- Pulizia: Use the provided cleaning cloth to wipe the meter's exterior and the sample chamber. Do not use abrasive cleaners or solvents.
- Magazzinaggio: Store the meter in its carrying case in a cool, dry place away from direct sunlight and extreme temperatures. Remove batteries if storing for extended periods.
- Calibrazione: Regular calibration is recommended to ensure accuracy. Refer to the full manual for detailed calibration procedures using appropriate standards.
- Gestione dei reagenti: Always handle chemical reagents with care, following safety guidelines provided by the reagent manufacturer.
7. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il dispositivo non si accende | Batterie scariche o installate in modo errato | Replace batteries with new 1.5V (AAA) batteries, ensuring correct polarity. |
| Letture imprecise |
|
|
| "Low Battery" indicator | Le batterie sono scariche | Replace all six 1.5V (AAA) batteries. |
8. Suggerimenti per l'utente
- Always use fresh reagents for the most accurate results.
- Garantire sample bottles are thoroughly cleaned and rinsed with distilled water before each use to avoid contamination.
- Perform a ZERO calibration frequently, especially if moving the device to a new environment or after prolonged storage.
- Keep the LCD screen clean for clear readability.
9. Garanzia e supporto
The LUTRON CL-2006 is certified with CE, indicating compliance with European safety, health, and environmental protection requirements.
For technical support, service, or warranty inquiries, please contact your local distributor or the manufacturer directly. Refer to your purchase documentation for specific warranty terms and contact information.