Aideepen TS457

TS457 High-precision Lithium Battery Internal Resistance Meter

Manuale d'uso

1. Introduzione e oltreview

The TS457 DC5V High-precision Lithium Battery Internal Resistance Meter is a versatile tool designed for accurately measuring the internal resistance and voltage of lithium batteries. This device is ideal for electricians, hobbyists, and anyone needing to assess battery health and performance. It features a clear display, intuitive controls, data storage capabilities, Bluetooth connectivity for app integration, and adjustable settings for enhanced usability.

TS457 Lithium Battery Internal Resistance Meter front view
Figure 1: TS457 Lithium Battery Internal Resistance Meter

2. Informazioni sulla sicurezza

  • NON FARE test AC power with this device.
  • NON FARE test volumetages above 45V to prevent damage to the meter and ensure user safety.
  • Ensure proper insulation when connecting wires, especially the yellow charging status wire, which should not be connected normally during operation.
  • Always handle batteries with care and follow battery manufacturer safety guidelines.

3. Contenuto della confezione

Si prega di controllare la confezione per verificare la presenza dei seguenti elementi:

  • 1 x TS457 Internal Resistance Tester
  • 1 x XH-2.54-3P Red-Black-Yellow Power Cable (150mm long)
  • 1 x XH-2.54-4P Signal Acquisition Cable (400mm long)

4. Specifiche

Caratteristica Descrizione
Metodo di alimentazione DC 5V power supply or 18650 battery power supply or 18650 battery + power adapter board (sold separately)
Volume di eserciziotage DC 5V (Do not exceed the voltage limite)
Principio di prova AC 4-wire method
Voltage Intervallo di prova 0.001V ~ 45.00V (Maximum Resolution: 0.001V)
Internal Resistance Measurement Range 0.1mΩ ~ 7.999Ω (Maximum Resolution: 0.1mΩ)
Registrazione dei dati Supports recording 20 sets of internal resistance measurement data. Only the most recent 5 sets are viewable on the device; all 20 sets can be viewed tramite l'app.
Voltage Display Fine-tuning Supportato
Internal Resistance Display Fine-tuning Supportato
Spegnimento automatico Supports 1-9 minutes of standby time adjustment
Luminosità della retroilluminazione Supports 1-9 levels of backlight brightness adjustment
Accessorio 1 XH-2.54-3P Red-Black-Yellow Power Cable (150mm)
Accessorio 2 XH-2.54-4P Signal Acquisition Cable (400mm)
Dimensioni del prodotto Dimensioni: 79 mm x 43 mm x 26 mm
Dimensioni dell'apertura di installazione 75 mm x 39 mm
Peso del prodotto Net weight 38g, with packaging 64g
Product dimensions and installation opening size
Figure 2: Product Dimensions and Installation Opening

5. Impostazione

5.1 metodi di alimentazione

The TS457 offers two primary methods for power supply:

  1. DC 5V Two-Wire Power Supply:

    • Connect the thin red wire to the positive electrode of your DC 5V power source.
    • Connect the thin black wire to the negative pole of your DC 5V power source.
    • The yellow wire indicates charging status and should NOT be connected normally during operation. Ensure proper insulation for this wire if not in use.
  2. 18650 Battery + Power Adapter Board:

    • Utilize an 18650 battery in conjunction with a compatible power adapter board (purchased separately) for portable operation.
Diagram showing two power supply methods for the TS457
Figure 3: Two Power Supply Methods

5.2 Connecting for Measurement (Kelvin Clamp Metodo)

For accurate measurements, especially of internal resistance, the AC 4-wire (Kelvin) method is recommended. You will need an XH2.54-4P signal acquisition cable and Kelvin clamps (accessories may need to be purchased separately).

  1. Prepare a 5V power supply or an 18650 battery for the meter.
  2. Connect the XH2.54-4P signal acquisition cable to the back of the meter.
  3. Attach Kelvin clamps to the ends of the signal acquisition cable.
  4. Connect the Kelvin clamps to the positive and negative terminals of the battery or component you wish to test. Ensure good contact.
Diagram demonstrating clamp test setup with Kelvin clamps
Figura 4: Clamp Test Demonstration with Kelvin Clamps
Diagram showing how to test using a battery test stand
Figure 5: Testing with a Battery Test Stand

6. Istruzioni per l'uso

6.1 Accensione/spegnimento

Premere il tasto ACCESO/SPENTO pulsante per accendere o spegnere il dispositivo.

6.2 Encoder Operation

The device features an encoder knob for efficient and fast operation. Rotate the knob to navigate menus and adjust settings. Press the knob to confirm selections.

Image highlighting the encoder knob for operation
Figure 6: Encoder Knob for Navigation and Adjustment

6.3 Visualizzazione dell'interfaccia

The TS457 features a clear display that shows voltage, resistance, and data. The interface changes based on the measurement status and selected menu.

Examples of different interface displays on the TS457
Figure 7: Various Interface Displays (Not Measured, During Measurement, Result Pass/Fail, Settings)

6.4 Archiviazione e ripristino dei datiview

The device can store up to 20 sets of internal resistance measurement data. While only the most recent 5 sets are directly viewable on the meter, all 20 sets can be accessed and reviewed through the dedicated mobile application.

Image showing 20 sets of data storage capacity
Figure 8: Data Storage Capacity

6.5 Calibrazione del display

The TS457 supports voltage and internal resistance display calibration, allowing users to fine-tune measurement results for optimal accuracy.

Image indicating support for display calibration
Figure 9: Display Calibration Feature

6.6 Regolazione della luminosità della retroilluminazione

Customize the screen brightness with 1 to 9 levels of adjustment to suit various lighting conditions.

Image showing 1-9 level backlight brightness adjustment
Figura 10: Regolazione della luminosità della retroilluminazione

6.7 Standby Time Settings

The automatic shutdown standby time can be flexibly set from 1 to 9 minutes, helping to extend battery life.

Image showing 1-9 minute standby time settings
Figure 11: Standby Time Settings

6.8 Bluetooth (BT) Communication and App Integration

The TS457 features built-in Bluetooth communication, allowing it to connect to a dedicated mobile application (e.g., Wuzhi Zhilian APP). The app provides extended functionality, including displaying, setting, and viewing historical data, as well as remote firmware updates.

Image showing BT communication with mobile app
Figure 12: Bluetooth Communication with App

6.9 Aggiornamento firmware OTA

The device supports Over-The-Air (OTA) firmware updates via the mobile app, enabling remote upgrades and customization.

  1. Add the ZK-T459 device to the Wuzhi Zhilian App.
  2. Fare clic sull'icona del dispositivo per accedere all'interfaccia operativa normale.
  3. Click on "OTA". If a new firmware prompt appears, click "Confirm".
  4. The app will go back to the list of application devices, and the "firmware update" option will appear.
  5. Press and hold the knob button on the device to turn on or set up the interface firmware upgrade, and enter the OTA mode interface.
  6. Click on "Firmware Update" in the top right corner of the device list interface of the APP application to enter the OTA operation interface. At this time, the BT connection icon will be displayed on the screen of the device to be upgraded.
  7. Click on 'Get device information', then click on 'Firmware Update'.
  8. The app will automatically complete the firmware upgrade.
  9. The progress bar for the upgrade is displayed as complete, and the APP automatically disconnects the BT connection of the device. Click "" to return to the APP device list interface.
Diagram showing OTA firmware update process via app
Figure 13: OTA Firmware Update Process

6.10 External Signal Ports

The device reserves NG/OK external signal ports for docking with automation equipment, facilitating automated batch testing, or expanding sound and light alarm prompt modules or other uses.

Image showing communication interface and NG/OK external signal port
Figure 14: Rich Interfaces with Communication and NG/OK Ports

7. Manutenzione

  • Keep the device clean and dry. Use a soft, dry cloth to wipe the screen and casing.
  • Evitare di esporre il dispositivo a temperature estreme, umidità o luce solare diretta.
  • Quando non lo si utilizza, conservare il misuratore in un luogo fresco e asciutto.
  • Non tentare di smontare o riparare il dispositivo da soli, poiché ciò invaliderebbe la garanzia e potrebbe causare danni.

8. Risoluzione Dei Problemi

Problema Possibile causa Soluzione
Il dispositivo non si accende Incorrect power supply connection; Power supply voltage too low/high; Faulty power source. Check power cable connections. Ensure power supply is DC 5V and within limits. Try a different power source.
Letture imprecise Poor contact with battery terminals; Calibration needed; Environmental interference. Ensure Kelvin clamps have good contact. Perform display calibration (refer to section 6.5). Test in a stable environment.
"oL" displayed on screen Overload or measurement out of range. Ensure the tested voltage is not above 45V and resistance is within 0.1mΩ~7.999Ω.
La connessione Bluetooth non riesce App not installed; Bluetooth disabled on phone/device; Device not in pairing mode. Install the Wuzhi Zhilian App. Enable Bluetooth on your mobile device. Follow app instructions for pairing (refer to section 6.8).
Firmware update issues Unstable Bluetooth connection; Interrupted update process. Ensure a stable Bluetooth connection during the update. Do not interrupt the process. Retry the update (refer to section 6.9).

9. Suggerimenti per l'utente

  • Leverage Data Storage: Utilize the 20-group data storage feature for comparative analysis of battery performance over time or across different batteries. Access all data via the mobile app for comprehensive review.
  • Ottimizzazione della visualizzazione: Adjust the backlight brightness (1-9 levels) to ensure optimal visibility in various working environments, from bright workshops to dimly lit areas.
  • Conserva la durata della batteria: Set the automatic standby time (1-9 minutes) to prevent unnecessary power consumption and extend the operational life of your power source.
  • Rimani aggiornato: Regularly check for and install firmware updates via the dedicated mobile app to ensure your device has the latest features and performance improvements.
  • Integrazione fai da te: For advanced users, explore the reserved NG/OK external signal ports for integration with automation systems or custom alarm modules for specialized testing setups.

10. Garanzia e supporto

Per informazioni sulla garanzia, supporto tecnico o richieste di assistenza, contattare direttamente il rivenditore o il produttore. Conservare la ricevuta d'acquisto come prova d'acquisto.

Documenti correlati - TS457

Preview TS457 VoltagManuale utente del tester di resistenza interna
Comprehensive user manual for the Aideepen TS457 Voltage Internal Resistance Tester. This guide details technical specifications, interface functions, power supply methods, testing procedures using Kelvin clamps and battery test stands, and various setting configurations for accurate DC voltage and internal resistance measurements.
Preview Aideepen ZK-T459 VoltagManuale utente e guida per tester di resistenza interna e
Manuale utente completo per Aideepen ZK-T459 Voltage tester di resistenza interna. Scopri le specifiche del prodotto, la configurazione, il funzionamento tramite manopola e app Bluetooth, i metodi di prova utilizzando Kelvin clampSupporti per batterie e batterie, aggiornamenti firmware e calibrazione. Offre test CA a 4 fili, ampi intervalli di misura e registrazione dei dati.
Preview Tester multifunzione Aideepen LCR-TC1: caratteristiche, specifiche e guida all'uso
Guida completa al tester multifunzione Aideepen LCR-TC1, che descrive in dettaglio le sue caratteristiche, i parametri prestazionali, le capacità di test dei componenti (transistor, diodi, resistori, condensatori, induttori), la decodifica IR e la risoluzione dei problemi. Scopri come utilizzare questo versatile analizzatore di componenti elettronici.
Preview Manuale utente dell'indicatore di batteria Aideepen VTM100 - Vol.tage monitoraggio SOC
Manuale utente completo per l'indicatore di batteria Aideepen VTM100. Scopri come monitorare la tensione CCtage, stato di carica (SOC) e temperatura per varie tipologie di batterie, come piombo-acido, litio ternario e LiFePO4.
Preview U-18 USB Voltage e Manuale dell'utente di Current Tester
Manuale utente completo per Aideepen U-18 USB Voltage Current Tester. Scopri le sue caratteristiche, le precauzioni di sicurezza, il funzionamento dell'interfaccia, le specifiche tecniche, i test del protocollo di ricarica rapida (QC, PD) e il software per PC per un'analisi dettagliata.
Preview Manuale utente del tester di transistor multifunzione LCR-T7 di Aideepen
Manuale utente per il tester di transistor multifunzione Aideepen LCR-T7, che illustra le caratteristiche, le istruzioni per l'uso, i test dei componenti e le specifiche tecniche dettagliate per vari componenti elettronici come BJT, diodi, condensatori e altro ancora.