MOES BAT-80A

MOES Tuya BT Intelligent Dual Power Controller 80A 16KW ATS Automatic Transfer Switch User Manual

Model: BAT-80A

Introduzione

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the MOES Tuya BT Intelligent Dual Power Controller (Model: BAT-80A). This device is designed to automatically switch between two power supply systems, typically a utility grid and an off-grid solar/wind power system, to ensure continuous power supply and optimize energy usage.

The controller facilitates flexible power transfer based on user-defined parameters, such as battery voltage levels, and supports remote control via the MOES and Tuya applications.

Prodotto finitoview

The MOES BAT-80A is a second-generation intelligent automatic transfer switch featuring enhanced capabilities for smart energy management. It is compatible with various battery types and offers adjustable set-points for seamless power transitions.

MOES Tuya BT Intelligent Dual Power Controller BAT-80A with smartphone showing app interface
Figure 1: MOES Tuya BT Intelligent Dual Power Controller BAT-80A with smartphone showing app interface for smart monitoring and control.
Comparison of 1st and 2nd Generation Dual Power Controllers
Figure 2: Comparison highlighting the 2nd Generation's smart control, low power BT protocol, and adjustable battery low voltage transfer and recovery set-points.
Updated Design with New Features and Product Parameter overview
Figure 3: Visual representation of the updated design and new features, including MOES APP Control, Max. Power up to 16KW, Manual Switching, and Surge Protection.

Configurazione e installazione

Before installation, ensure all power sources are disconnected to prevent electrical shock. The controller requires connection to a battery system for power and data acquisition.

Schema elettrico

The following diagram illustrates the typical connection for the dual power controller in an off-grid solar/wind system. Ensure all connections are secure and follow local electrical codes.

Product Function Diagram showing connections for Grid, Solar/Wind, Load, and Battery
Figure 4: Product Function Diagram illustrating the automatic transfer process between public power (grid) and inverter (solar/wind/battery) based on battery consumption and recovery.

Punti di connessione:

  • Public Power (L, N): Connect to the utility grid input.
  • Output (L, N): Connect to your household load.
  • Inverter (L, N): Connect to the output of your solar/wind inverter.
  • Battery (+, -): Collegati alla tua batteria.

Accensione iniziale

  1. Connect the battery to the controller. The controller will power on using battery power.
  2. Connect the utility grid and inverter outputs to their respective inputs on the controller.
  3. Connect your loads to the controller's output.

APP Connection (MOES/Tuya)

Per abilitare il controllo e il monitoraggio remoti:

  1. Download the MOES or Tuya APP on your smartphone.
  2. Assicurarsi che il controller sia acceso.
  3. Open the APP and follow the on-screen instructions to add a new device.
  4. Connect via Bluetooth (BT). Note: Remote control requires a Tuya BT gateway (not included).

Istruzioni per l'uso

The BAT-80A controller operates primarily in automatic mode, managing power transfer based on configured settings. It also features a manual switch function for user convenience.

Automatic Transfer Mode

The controller automatically switches between the utility grid and your off-grid system based on the battery voltage set-points:

  • Quando la batteria è scaricatage drops below the configured "Battery Low Voltage Transfer Set-Point", the controller will automatically switch the load to the utility grid. This protects your battery from over-discharge.
  • Quando la batteria è scaricatage recovers and rises above the configured "Battery Recovery Set-Point", the controller will automatically switch the load back to the inverter (solar/wind power).

The APP allows you to monitor these states and adjust parameters remotely.

Large LCD Display showing various power statuses and MOES app interface
Figure 5: The large LCD display provides real-time information on battery voltage, grid status, inverter status, and load current. The app interface mirrors these readings, showing automatic mode switching for grid and inverter power.

Commutazione manuale

The controller includes an updated manual switch function, allowing you to manually override the automatic transfer for specific situations.

AC Test Function

The device features an AC test function. If the inverter AC output is abnormal, the controller will automatically switch to public power to maintain continuous supply to the load.

Schermo LCD

The large LCD display shows critical information:

  • Battery real-time voltage
  • Working status of public power (grid)
  • Working status of inverter
  • Current, power, and power consumption of the load

Manutenzione

To ensure optimal performance and longevity of your Dual Power Controller, follow these maintenance guidelines:

  • Ispezione regolare: Controllare periodicamente tutti i collegamenti elettrici per assicurarsi che siano ben saldi e privi di corrosione.
  • Pulizia: Mantenere il dispositivo pulito e privo di polvere e detriti. Utilizzare un panno morbido e asciutto per la pulizia. Non utilizzare detergenti liquidi.
  • Ventilazione: Assicurarsi che il controller sia installato in un'area ben ventilata per evitare il surriscaldamento.
  • Aggiornamenti del firmware: Check the MOES/Tuya APP regularly for any available firmware updates for the device to ensure you have the latest features and bug fixes.

Risoluzione dei problemi

If you encounter issues with your Dual Power Controller, refer to the following common troubleshooting steps:

  • Il controller non si accende: Ensure the battery is properly connected and has sufficient charge. The controller is powered by the battery.
  • Nessun trasferimento automatico:
    • Verify that the "Battery Low Voltage Transfer Set-Point" and "Battery Recovery Set-Point" are correctly configured in the APP or on the device.
    • Ensure the recovery voltage is set higher than the cut-off voltage.
    • Check the status of both the utility grid and the inverter for any faults.
  • Problemi di connettività dell'APP:
    • Assicurati che il Bluetooth sia abilitato sul tuo smartphone.
    • Confirm that a Tuya BT gateway (not included) is properly set up and within range for remote control.
    • Restart the APP and the controller.
  • Abnormal Inverter AC Output: The device is designed to automatically switch to public power if it detects an abnormal AC output from the inverter. Check your inverter for any issues.

Specifiche

Detailed technical specifications for the MOES BAT-80A Dual Power Controller:

ParametroValore
ModelloBAT-80A
Potenza nominale8KW (Utility Power 100-120V); 16KW (Utility Power 220-240V)
Ingresso volumetageSelezione automatica: CA 100-120 V o CA 220-240 V
Volume di uscitatageSelezione automatica: CA 100-120 V o CA 220-240 V
Transfer Time (Inverter to Utility)≤10 ms
Transfer Time (Utility to Inverter)≤16 ms
Schermo LCDVolume della batteriatage; Power source: Utility Power or Battery-Inverter.
Volume di sistematageSelezione automatica: 12V o 24V o 48V
Batteria scaricatage Transfer Set-PointsDefault: 10.5V/21V/42V, adjustable
Battery Recovery Set-PointsDefault: 12.5V/25V/50V, adjustable
ApplicazioneOff-grid solar system; Wind generator; Hydro generator
Dimensioni dell'articolo190 * 170 * 72.5 mm (7.5 * 6.7 * 2.9 pollici)
Peso dell'articolo1.32kg (2.9lb)
Dimensioni del pacco225 * 220 * 170 mm (8.9 * 8.7 * 6.7 pollici)
Peso del pacco1.63kg (3.6lb)
Physical dimensions of the MOES BAT-80A Dual Power Controller
Figure 6: Physical dimensions of the MOES BAT-80A Dual Power Controller, showing front, side, and bottom viewcon misure.

Suggerimenti per l'utente

  • Compatibilità della batteria: The controller is suitable for various battery types, including sealed, gel, lead-acid, and lithium batteries.
  • Voltage Set-Points: Always ensure your "Battery Recovery Set-Point" is configured to be higher than your "Battery Low Voltage Transfer Set-Point" to allow for proper battery charging and system cycling.
  • Ottimizza il risparmio energetico: Utilize the MOES/Tuya APP to monitor your power consumption and adjust transfer parameters to maximize the use of your solar or wind power system, thereby increasing energy-saving efficiency.
  • Sostituzione manuale: Use the manual switch function when you need immediate control over the power source, for example, during system testing or specific load requirements.

Garanzia e supporto

The package includes one Dual Power Automatic Transfer Switch and one User's Manual. For any technical support, warranty claims, or further inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt for warranty purposes.

Documenti correlati - BAT-80A

Preview Manuale utente dell'interruttore di trasferimento automatico intelligente MOES BAT-80A ATS
Manuale utente completo per l'interruttore di trasferimento automatico intelligente (ATS) MOES BAT-80A. Include informazioni su installazione, specifiche tecniche, display LCD, funzioni dei pulsanti, raccomandazioni di sicurezza e associazione del dispositivo all'app MOES.
Preview Manuale utente dell'interruttore di trasferimento automatico intelligente (ATS) MOES BAT-80A
Manuale utente completo per l'interruttore di trasferimento automatico intelligente (ATS) MOES BAT-80A. Questa guida fornisce istruzioni dettagliate per l'installazione, schemi di collegamento, specifiche tecniche, funzionamento e risoluzione dei problemi per sistemi solari, eolici e idroelettrici fuori rete.
Preview Manuale utente dell'interruttore di trasferimento automatico
Manuale utente per l'interruttore di trasferimento automatico intelligente (ATS) Dual Power di MOES, che descrive in dettaglio installazione, funzionamento, specifiche e raccomandazioni di sicurezza per sistemi solari ed eolici fuori rete.
Preview Manuale di istruzioni del modulo commutatore intelligente ZigBee 3 Gang MS-104CZ
Guida all'installazione e all'utilizzo del modulo commutatore intelligente ZigBee 3 Gang MS-104CZ. Sono incluse le istruzioni di cablaggio, la configurazione dell'applicazione, il pannello di controllo e le informazioni di garanzia.
Preview Manuale d'uso e installazione del termostato intelligente per radiatore MOES BRT-100
Manuale utente completo per il termostato intelligente per radiatori (TRV) MOES BRT-100 Zigbee. Include istruzioni per l'installazione, il funzionamento, la programmazione, le impostazioni avanzate e la risoluzione dei problemi.
Preview Manuale utente MOES Smart Bluetooth Fingerbot BS-FB-V3
Manuale utente per MOES Smart Bluetooth Fingerbot (BS-FB-V3), che copre il prodottoview, specifiche, installazione, connessione tramite app, controllo del dispositivo e informazioni sul servizio. Scopri come automatizzare la tua casa con questo pulsante intelligente.