1. Introduzione
This manual provides essential information for the safe and efficient operation, setup, and maintenance of your Hobbywing 12L Brushless Water Pump. This high-performance peristaltic pump is designed for demanding applications such as agricultural sprayers and drones, offering precise flow control and robust construction. Please read this manual thoroughly before installation and use.
2. Informazioni sulla sicurezza
- Scollegare sempre l'alimentazione prima di eseguire qualsiasi operazione di installazione, manutenzione o risoluzione dei problemi.
- Ensure all electrical connections are secure and properly insulated to prevent short circuits and electric shock.
- Operate the pump within its specified voltage range (14-18S LiPo, 44-81V) to prevent damage.
- Avoid direct contact with moving parts during operation.
- Do not immerse the pump in water beyond its IP66 rating. While water-resistant, it is not designed for continuous submersion.
- Use appropriate personal protective equipment (PPE) when handling chemicals or operating the pump in hazardous environments.
- Tenere fuori dalla portata dei bambini.
3. Prodotto finitoview
The Hobbywing 12L Brushless Water Pump is a compact and powerful unit featuring a brushless motor for efficiency and longevity. It supports both CAN and PWM control for flexible integration into various systems. Its peristaltic design ensures consistent flow and prevents fluid contamination of internal components.
Caratteristiche principali:
- Brushless Motor: For high efficiency and extended lifespan.
- Dual Control Modes: Supports CAN and PWM for versatile integration.
- High Flow Rate: Up to 12L/min (2 channels, 6L/min each).
- Ampio volumetage Range: Compatible with 14-18S LiPo batteries (44-81V).
- IP66 Protection: Resistant to dust and powerful water jets.
- Peristaltic Design: Ensures precise dosing and prevents fluid contact with pump mechanics.
Componenti:
The pump unit includes the main pump body, integrated brushless motor, control electronics, and connection cables for power and signal. Mounting brackets are typically integrated into the design for easy installation.


4. Specifiche
| Parametro | Valore |
|---|---|
| Utilizzando il voltage | 14-18S LiPo (44-81V) |
| Potenza nominale | 150W |
| Maximum Opening Flow | 12L/min (2 channels, 6L/min each) |
| Minimum Opening Flow | 0.6 l/min |
| Canali | 2 |
| Grado di protezione | Grado di protezione IP66 |
| Peso | 778g |
| Size (excluding wire) | 151 x 75 x 124 mm |
| Inner Diameter of Inlet Water Pipe | 8mm |
| Inner Diameter of Outlet Water Pipe | 8mm |
| Fixed PWM Throttle Travel | 1050-1950 μs |
| PWM Level | 3.3 V/5 V |
5. Impostazione
5.1 Montaggio
Securely mount the pump to a stable surface on your agricultural sprayer or drone using appropriate fasteners. Ensure the mounting location allows for proper hose routing and access for maintenance. The pump should be mounted in an orientation that minimizes strain on the water pipes and electrical connections.

5.2 Water Pipe Connections
- Connect the inlet water pipe (8mm inner diameter) from your fluid reservoir to the designated inlet port(s) on the pump.
- Connect the outlet water pipe(s) (8mm inner diameter) from the pump to your spray nozzles or distribution system.
- Ensure all pipe connections are tight and leak-free. Use hose clamps if necessary to prevent accidental disconnections or leaks during operation.
5.3 collegamenti elettrici
- Collegamento elettrico: Connect the main power cable of the pump to a compatible 14-18S LiPo battery or power source. Observe correct polarity (red for positive, black for negative).
- Control Signal Connection:
- Controllo PWM: Connect the PWM signal wire to your flight controller or control unit. Ensure the PWM level is 3.3V or 5V and the throttle travel is within 1050-1950μs.
- CAN Control: If using CAN, connect the CAN bus wires (CAN-H and CAN-L) to your CAN-enabled flight controller or control system. Refer to your flight controller's manual for specific CAN bus setup.
- Double-check all electrical connections before applying power.
6. Istruzioni per l'uso
6.1 Controllo pre-operativo
- Verify all connections (power, signal, water pipes) are secure.
- Ensure the fluid reservoir contains sufficient liquid.
- Check for any obstructions in the water pipes or nozzles.
6.2 Avviamento della pompa
Once all connections are verified and the system is ready, apply power to the pump. The pump will typically enter a standby mode. Use your flight controller or control unit to send the appropriate PWM or CAN command to start the pump.
6.3 Regolazione della portata
The flow rate can be adjusted via the PWM signal (throttle travel 1050-1950μs) or CAN commands from your control system. Experiment with different signal values to achieve the desired flow for your application.
6.4 Arresto della pompa
Send a stop command via PWM or CAN from your control unit. Disconnect the main power source after use.
7. Manutenzione
7.1 Pulizia regolare
- After each use, especially when spraying chemicals, flush the pump and lines with clean water to prevent residue buildup and corrosion.
- Pulisci l'esterno della pompa con dell'adamp stoffa. Non utilizzare prodotti chimici o solventi aggressivi.
7.2 Ispezione
- Periodically inspect water pipes for cracks, kinks, or blockages.
- Check electrical cables for any signs of wear, fraying, or damage.
- Ensure mounting screws remain tight.
7.3 Conservazione
Store the pump in a clean, dry environment away from direct sunlight and extreme temperatures. If storing for an extended period, ensure the pump and lines are thoroughly cleaned and dry.
8. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| La pompa non si avvia | No power; incorrect voltage; faulty signal connection; pump damaged. | Check power supply and connections; verify voltage is within 14-18S; inspect signal wiring; contact support if pump is damaged. |
| Nessun flusso di fluido | Empty reservoir; clogged pipes/nozzles; air in the system; pump not primed. | Refill reservoir; clear obstructions; ensure system is free of air; prime the pump if necessary. |
| Inconsistent flow | Partial blockage; fluctuating power/signal; worn peristaltic tubing. | Check for partial blockages; ensure stable power and control signal; inspect peristaltic tubing for wear. |
| Rumore/vibrazioni eccessivi | Loose mounting; foreign object in pump; motor issue. | Tighten mounting screws; inspect pump for foreign objects (after disconnecting power); contact support if motor issue suspected. |
9. Suggerimenti per l'utente
- For optimal performance and longevity, always use clean fluids and regularly flush the system.
- When integrating with a flight controller, ensure the PWM or CAN settings are correctly configured to match the pump's requirements.
- Consider using a filter on the inlet line to prevent debris from entering the pump and clogging nozzles.
- Regularly check the condition of the peristaltic tubing, as it is a wear item and may need replacement over time depending on usage and fluid type.
10. Garanzia e supporto
Per informazioni sulla garanzia, supporto tecnico o richieste di assistenza, contattare direttamente il rivenditore o il produttore. Conservare la prova d'acquisto per eventuali reclami in garanzia.





