The Braun ThermoScan Tympanic Ear Thermometer, Model IRT4520MNLA, is designed to provide accurate and reliable temperature readings. Utilizing Braun's patented pre-warmed tip and ExacTemp technology, this device is a trusted choice among health professionals for its precision and ease of use. It is suitable for infants, children, and adults, offering readings in both Fahrenheit and Celsius.
Image: Braun ThermoScan Tympanic Ear Thermometer with its protective case.
Caratteristiche principali:
- Professional technology ensures accuracy every time.
- Fast, gentle, and easy to use.
- Recommended for infants, children, and adults.
- Displays readings in Fahrenheit or Celsius.
- Includes thermometer, protective case, 21 disposable lens filters, and 2 AA batteries.
Impostare
- Installa le batterie: Open the battery compartment (usually located at the bottom or back of the device). Insert the 2 AA batteries provided, ensuring correct polarity (+/-). Close the compartment securely.
- Attach a New Lens Filter: The thermometer requires a new, clean disposable lens filter for each measurement to ensure hygiene and accuracy.
- Rimuovere il termometro dalla custodia protettiva.
- Gently push a new disposable lens filter onto the thermometer tip until it clicks into place. Ensure it is seated firmly.
- Accensione iniziale: Premere il pulsante di accensione (⏻) to turn on the thermometer. The display will show a brief self-test, followed by the last temperature reading, and then three dashes (---) indicating it is ready for use.
Image: Illustration showing how to insert batteries into the thermometer.
Image: Illustration demonstrating how to attach a new disposable lens filter to the thermometer tip.
Istruzioni per l'uso
- Preparazione alla misurazione: Ensure a new, clean disposable lens filter is securely attached to the thermometer tip.
- Posizionare il termometro: Gently insert the thermometer tip into the ear canal. For accurate readings, ensure the probe is aimed towards the opposite temple. For children under 1 year, gently pull the ear straight back. For children over 1 year and adults, gently pull the ear up and back.
- Take Temperature: Press and release the temperature button (usually indicated by a thermometer icon). A long beep will signal the completion of the measurement.
- Leggi il display: The temperature reading will be displayed on the screen. The ExacTemp technology confirms secure position and accurate reading with a light and a beep.
- Remove and Discard Lens Filter: Press the eject button (usually located near the probe) to remove and discard the used lens filter. Avoid touching the used filter.
- Spegni: The thermometer will automatically turn off after 60 seconds of inactivity to conserve battery life, or you can manually press and hold the power button (⏻) finché il display non si spegne.
Image: Diagram illustrating correct thermometer positioning in an adult's ear.
Image: Diagram illustrating correct thermometer positioning in a child's ear.
Manutenzione
- Cleaning the Thermometer: After each use, and after discarding the lens filter, wipe the probe and the main body of the thermometer with an alcohol swab or a soft cloth dampened with alcohol. Do not immerse the thermometer in water or any cleaning solution.
- Sostituzione dei filtri dell'obiettivo: Always use genuine Braun disposable lens filters to ensure accuracy and hygiene. Replace the lens filter after each use.
- Sostituzione della batteria: When the low battery indicator appears on the display, replace the 2 AA batteries. Ensure the battery compartment is closed securely after replacement.
- Magazzinaggio: Store the thermometer in its protective case in a dry, clean location away from direct sunlight and extreme temperatures.
Image: A hand cleaning the thermometer probe with an alcohol wipe.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Letture imprecise | Used or improperly attached lens filter; incorrect probe positioning; earwax obstruction. | Ensure a new, clean lens filter is attached correctly. Verify proper probe positioning. Consult a healthcare professional if earwax is suspected. |
| "POS" or "ERR" displayed | Incorrect probe positioning or movement during measurement. | Re-position the thermometer correctly in the ear canal and remain still during measurement. |
| Indicatore di batteria scarica | Le batterie si stanno scaricando. | Replace the 2 AA batteries with new ones. |
| Il termometro non si accende | Batterie scariche; installazione errata delle batterie. | Controllare l'installazione delle batterie e sostituirle se necessario. |
Specifiche
- Numero modello: IRT4520MNLA
- Dimensioni del prodotto: 9.21 x 6.38 x 2.28 pollici
- Peso: 3.53 once
- Fonte di energia: 2 batterie AA (incluse)
- Tipo di visualizzazione: Digitale
- Metodo di misurazione: Tympanic (Ear)
- Caratteristica speciale: High Accuracy, ExacTemp Technology, Pre-warmed Tip
- Componenti inclusi: Thermometer, protective case, 21 disposable lens filters, 2 batteries
- Cura del prodotto: Pulisci Pulire
Garanzia e supporto
Braun products are manufactured to meet the highest quality standards. In the unlikely event of a defect in materials or workmanship, your Braun ThermoScan Tympanic Ear Thermometer is covered by a limited warranty from the date of purchase. Please refer to the warranty card included in your product packaging for specific terms and conditions.
For technical support, troubleshooting assistance, or to inquire about replacement parts (such as disposable lens filters), please visit the official Braun webo contattare il servizio clienti. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.