1. Prodotto finitoview
The RAB Lighting LFP16A Sleek Floodlight is designed for outdoor illumination, providing efficient and durable lighting. This fixture accommodates a PAR16 type bulb and features a robust die-cast aluminum housing with a powder-coated finish for enhanced durability and weather resistance.
Caratteristiche principali:
- Designed for 60W PAR16 bulbs, delivering 650 lumens output (bulb not included).
- Durable die-cast aluminum housing with a powder-coated finish.
- Gasket and O-ring seals provide resistance against weather elements.
- Integrated shield helps reduce glare.
- Equipped with a 1/2" NPS threaded arm for secure mounting and a locking swivel for adjustable positioning.

Figure 1: RAB Lighting LFP16A Sleek Floodlight. This image shows the floodlight fixture with its threaded arm and wiring, highlighting its compact and durable design.
2. Informazioni sulla sicurezza
Si prega di leggere attentamente tutte le istruzioni prima di installare o utilizzare questo prodotto. La mancata osservanza di queste istruzioni può causare scosse elettriche, incendi o altri pericoli che potrebbero causare danni alla proprietà o lesioni personali.
- Sicurezza elettrica: Always disconnect power at the circuit breaker or fuse box before wiring or servicing the fixture.
- Elettricista qualificato: L'installazione deve essere eseguita da un elettricista qualificato, nel rispetto di tutte le normative elettriche locali e nazionali.
- Messa a terra: Assicurarsi che l'apparecchio sia correttamente collegato a terra per evitare potenziali pericoli elettrici.
- Tipo di lampadina: Use only PAR16 type bulbs with a maximum wattage di 60W. Superamento del watt massimotagpuò causare surriscaldamento e danni all'apparecchio.
- Posizione bagnata: This fixture is suitable for wet locations. Ensure all connections are properly sealed and waterproofed during installation.
- Temperatura: Do not install near combustible materials or surfaces that may be affected by heat.
3. Contenuto della confezione
Verificare che tutti i componenti siano presenti prima di iniziare l'installazione:
- RAB Lighting LFP16A Sleek Floodlight Fixture (1)
- Manuale di istruzioni (1)
Note: Light bulb and wire connectors are not included and must be purchased separately.
4. Configurazione e installazione
This floodlight is designed for wall mounting and features a 1/2" NPS threaded arm for secure attachment to a junction box or mounting accessory. Follow these steps for proper installation:
- Prepararsi per l'installazione:
- Prima di iniziare qualsiasi lavoro elettrico, disattivare l'alimentazione elettrica tramite l'interruttore automatico.
- Gather necessary tools: screwdriver, wire strippers, electrical tape, silicone sealant (for waterproofing).
- Montare l'apparecchio:
- Thread the 1/2" NPS arm of the floodlight into a compatible outdoor junction box or mounting plate. Ensure a tight and secure connection.
- Use the locking swivel to adjust the initial angle of the fixture.

Figure 2: Detail of the 1/2" NPS threaded arm and 180-degree adjustable swivel. This illustrates the mounting mechanism and flexibility of the floodlight.
- Collegamenti elettrici:
- Connect the black wire from the fixture to the hot (black) wire from the power supply.
- Connect the white wire from the fixture to the neutral (white) wire from the power supply.
- Connect the bare copper or green wire from the fixture to the ground wire from the power supply.
- Secure all connections with appropriate wire connectors and electrical tape. For outdoor installations, consider using silicone-filled wire nuts for added moisture protection.
- Installa la lampadina:
- Carefully insert a PAR16 bulb (max 60W) into the fixture socket. Do not overtighten.
- Seal and Test:
- Ensure all connections are secure and the fixture is properly sealed against moisture. Apply silicone sealant around the mounting base if necessary.
- Restore power at the circuit breaker and test the floodlight's operation.
5. Istruzioni per l'uso
Once installed and powered, the RAB Lighting LFP16A Floodlight operates by the control of the circuit it is connected to (e.g., a wall switch, timer, or photocell). There are no direct controls on the fixture itself.
- Regolazione della direzione della luce: The fixture features a locking swivel arm. To adjust the light direction, loosen the locking nut on the swivel, position the floodlight as desired, and then tighten the locking nut securely.
- Riduzione dell'abbagliamento: The built-in shield is designed to minimize glare, directing light effectively to the intended area.

Figura 3: Esample of the LFP16A floodlight used in a landscape setting, demonstrating its illumination capabilities.
6. Manutenzione
Una manutenzione regolare garantisce prestazioni ottimali e longevità del proiettore.
- Pulizia: Pulire periodicamente l'esterno dell'apparecchio con un panno morbido eamp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish. Ensure power is off before cleaning.
- Sostituzione della lampadina:
- Disattivare l'alimentazione dell'apparecchio tramite l'interruttore automatico.
- Lasciare raffreddare completamente la vecchia lampadina prima di maneggiarla.
- Carefully unscrew and remove the old PAR16 bulb.
- Insert a new PAR16 bulb (max 60W) into the socket, ensuring it is seated correctly.
- Ripristinare l'alimentazione e testare la nuova lampadina.
- Ispezione: Annually inspect the fixture for any signs of wear, damage, or loose connections. Address any issues promptly.
7. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| La luce non si accende. | Nessuna alimentazione al dispositivo. Lampadina difettosa. Collegamento del cablaggio allentato. | Controllare l'interruttore. Sostituire la lampadina. Ispezionare e fissare il cablaggio (assicurarsi che l'alimentazione sia disattivata). |
| Sfarfallio di luce. | Lampadina allentata. Tipo di lampadina incompatibile. Alimentazione elettrica fluttuante. | Stringere la lampadina. Ensure correct PAR16 bulb is used. Consult an electrician if power supply is unstable. |
| Acqua all'interno dell'apparecchio. | Sigillatura non corretta durante l'installazione. Damaged gasket/O-ring. | Turn off power, disassemble, dry, re-seal all connections and mounting points with silicone sealant. Contact RAB Lighting for replacement parts if necessary. |
8. Specifiche
| Attributo | Dettaglio |
|---|---|
| Numero di modello | LFP16A |
| Produttore | Illuminazione RAB |
| Fonte di alimentazione | Elettrico cablato |
| Voltage | 120 Volt |
| Cosatage (massimo) | 60 watt |
| Tipo di lampadina | PAR16 (HPS, LED compatible) |
| Materiale | Die-cast Aluminum (Housing), Plastic (Internal components) |
| Fine | Powder-coated (Bronze color) |
| Tipo di montaggio | Wall (1/2" NPS threaded arm) |
| Peso dell'articolo | 10.4 once |
| Diametro assemblato | 2-7/16 pollici |
| Componenti inclusi | Apparecchio di illuminazione |
| Batterie richieste | NO |
9. Garanzia e supporto
The RAB Lighting LFP16A Sleek Floodlight comes with a Garanzia del produttore di 1 anni dalla data di acquisto. Questa garanzia copre difetti di materiali e lavorazione in condizioni di normale utilizzo.
For warranty claims, technical support, or further assistance, please contact RAB Lighting customer service. Refer to the official RAB Lighting websito per le informazioni di contatto più aggiornate.
Produttore: Illuminazione RAB
Websito: www.rablighting.com (Exampil collegamento (il collegamento effettivo può variare)