ABB RC5

ABB RC5-1/250 Surge Suppressor User Manual

Model: RC5-1/250 | Part Number: 1SBN050100R1002

1. Introduzione

This manual provides essential information for the safe and effective installation, operation, and maintenance of the ABB RC5-1/250 Surge Suppressor. Please read this manual thoroughly before using the product and retain it for future reference.

The ABB RC5-1/250 is designed to protect electrical equipment from transient overvoltages, ensuring reliable performance and extending the lifespan of connected devices. It is suitable for use with N, A9...A40, AS, NS series contactors and motor starters.

2. Informazioni sulla sicurezza

AVVERTIMENTO: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect power before installation or servicing.

Observe all local and national electrical codes. Failure to follow these instructions may result in serious injury or death.

3. Prodotto finitoview

The ABB RC5-1/250 is a compact surge suppressor designed for easy integration with ABB control devices. Its primary function is to absorb transient voltage spikes, protecting sensitive electronic components.

ABB RC5-1/250 Surge Suppressor, top-side view

Figure 3.1: Top-side view of the ABB RC5-1/250 Surge Suppressor. The image shows the grey rectangular body with two metal prongs extending from the bottom. Markings on the top surface include "ABB", "RC5-1/250", "110-250V~", UL and CE certifications, and "Use with: N, A9...A40, AS, NS".

Caratteristiche principali:

4. Configurazione e installazione

The RC5-1/250 surge suppressor is designed for simple, direct mounting onto compatible ABB contactors and motor starters.

  1. Disconnessione dell'alimentazione: Ensure all power to the control circuit and associated equipment is disconnected and locked out before beginning installation. Verify with a voltagetester.
  2. Identificare la posizione di montaggio: Locate the designated top or side mounting slots on your ABB N, A9...A40, AS, or NS series contactor or motor starter.
  3. Insert Suppressor: Align the prongs of the RC5-1/250 suppressor with the corresponding slots on the contactor. Gently push the suppressor firmly into place until it clicks or is securely seated. Ensure a proper electrical connection is made.
  4. Verifica connessione: Visually inspect the installed suppressor to ensure it is flush and securely attached to the contactor.
  5. Ripristina alimentazione: Una volta completata e verificata l'installazione, ripristinare l'alimentazione al circuito.

For detailed diagrams specific to your contactor model, refer to the contactor's instruction manual.

5. Istruzioni per l'uso

The ABB RC5-1/250 Surge Suppressor operates passively and requires no user interaction once installed. It continuously monitors the control circuit for transient overvoltages and diverts excess energy to protect the connected equipment.

Its operation is automatic and transparent to the user. The suppressor functions as a protective device, activating only when a voltage spike occurs. There are no indicators or controls on the suppressor itself.

6. Manutenzione

The ABB RC5-1/250 Surge Suppressor is a maintenance-free device. Regular inspection of the electrical system it protects is recommended.

Always disconnect power before performing any inspection or maintenance.

7. Risoluzione Dei Problemi

The RC5-1/250 is a passive component, and direct troubleshooting is limited. Most issues related to surge protection will manifest in the protected equipment.

ProblemaPossibile causaSoluzione
Protected equipment still experiences damage from voltage picchi.
  • 1. Suppressor is damaged or has reached end-of-life.
  • 2. Incorrect suppressor installed for the application.
  • 3. Surge event exceeds suppressor's capacity.
  • 4. Installazione non corretta.
  • 1. Replace the RC5-1/250 suppressor.
  • 2. Verify the suppressor's specifications match the circuit requirements.
  • 3. Consider additional surge protection measures for the entire electrical system.
  • 4. Re-check installation as per Section 4.
Suppressor appears physically damaged (e.g., cracked casing, burnt marks).Severe overvoltage event or internal failure.Immediately disconnect power and replace the suppressor. Do not attempt to repair.

If issues persist, contact a qualified electrician or ABB technical support.

8. Specifiche

ParametroValore
Numero di modelloRC5-1/250
Numero di parte1SBN050100R1002
MarcaFIGURA
Volume di eserciziotage110-250 V CA, 50/60 Hz
CompatibilitàABB N, A9...A40, AS, NS series contactors/motor starters
Tipo di montaggioTop/Side Mounted
Dimensioni del prodotto (L x P x A)9.06 x 14.57 x 12.4 inches (Packaging/Shipping dimensions, actual unit is smaller)
Peso dell'articolo18.3 Pounds (Shipping weight, actual unit is lighter)
CertificazioniUL Listed, CE, EAC

Note: Product dimensions and weight listed are typically for shipping packaging. The actual suppressor unit is compact.

9. Garanzia e supporto

For information regarding product warranty, please refer to the official ABB warranty policy available on the ABB website or contact your local ABB distributor.

For technical support, product inquiries, or service, please visit the official ABB website or contact ABB customer service through the contact information provided on their website. When contacting support, please have your product model number (RC5-1/250) and part number (1SBN050100R1002) ready.

ABB Ufficiale Websito: www.abb.com

Documenti correlati - RC5

Preview ABB High VoltagGuida all'acquisto degli scaricatori di sovratensione: selezione e informazioni tecniche
Guida completa per l'acquirente di ABB che descrive in dettaglio l'alta volatilitàtagScaricatori di sovratensione (PEXLIM, TEXLIM, EXLIM). Include specifiche tecniche, procedure di selezione, caratteristiche progettuali e linee guida applicative per la protezione delle infrastrutture elettriche.
Preview Controllore per robot industriali ABB IRC5: caratteristiche, varianti e specifiche
Scopri il controller per robot industriali ABB IRC5, una soluzione leader nel campo della robotica. Questo documento ne descrive le caratteristiche principali, tra cui controllo avanzato del movimento, funzionalità di sicurezza e ampia compatibilità. Descrive inoltre le diverse varianti del controller IRC5: Single Cabinet, Compact, PMC e Paint, insieme alle relative specifiche tecniche e all'hardware associato, come FlexPendant e RobotStudio Online.
Preview Interruttore automatico ABB Vmax: istruzioni per l'installazione e la manutenzione
Manuale completo di installazione e assistenza per ABB Vmax medium voltage circuit breakers, covering models from 12-17.5 kV, 630-1250 A, and 16-31.5 kA. Includes safety guidelines, operational procedures, maintenance, and spare parts information.
Preview ABB i-bus KNX 4-Channel SMI LoVo Shutter/Blind Actuator REG SJR/S 4.24.2.1
Technical data and connection diagram for the ABB i-bus KNX 4-channel SMI LoVo Shutter/Blind Actuator, model SJR/S 4.24.2.1. This device controls up to four SMI LoVo shutter or blind drives (24V) for positioning blinds, shutters, awnings, and other coverings via ABB i-bus KNX. It features manual operation buttons and status LEDs.
Preview Guida all'installazione del gateway ABB Ability™ Smart Sensor con Huawei E8372
Istruzioni dettagliate per l'installazione e la configurazione dell'ABB Ability™ Smart Sensor Gateway utilizzando un modem WiFi USB Huawei E8372. Scopri come connetterti, impostare i parametri di rete e verificare lo stato del gateway.
Preview ABB PCS100 AVC-20 Active VoltagCatalogo tecnico e Conditioner
Questo catalogo tecnico fornisce informazioni complete sul convertitore di frequenza attivo ABB PCS100 AVC-20tage Conditioner, che descrive in dettaglio le sue caratteristiche, i vantaggi, le specifiche tecniche, le applicazioni, la guida alla selezione, le planimetrie, le opzioni, l'interfaccia utente, i collegamenti, i requisiti di installazione e il supporto tecnico.