1. Introduzione
This manual provides detailed instructions for the installation, operation, and maintenance of the Eltako NLZ61NP-UC Timer Relay. This device is designed for building installation and control technology applications, offering precise timing functions for various electrical circuits.
2. Istruzioni di sicurezza
Osservare sempre le seguenti precauzioni di sicurezza:
- L'installazione e la manutenzione devono essere eseguite esclusivamente da un elettricista qualificato.
- Disconnect power to the circuit before installation, wiring, or maintenance.
- Ensure all connections are secure and correctly wired according to the diagram.
- Non superare il volume specificatotage valori nominali di corrente del dispositivo.
- Proteggere il dispositivo da umidità, polvere e temperature estreme.
- Questo dispositivo è destinato esclusivamente all'uso in ambienti interni.
3. Prodotto finitoview
The Eltako NLZ61NP-UC is a compact timer relay designed for series installation. It features adjustable delay functions and robust terminal connections.
Figura 1: Eltako NLZ61NP-UC Timer Relay. This image displays the blue, octagonal-shaped timer relay with its various terminals and adjustment potentiometers. Visible labels include 'CE', 'Eltako NLZ61NP-UC', 'A1-A2 8-230V~', 'L-N 230V~', 'RV', 'AV', '12min', 'μ 10A/250V~', and connection points for L, N, and 3.
Componenti chiave:
- A1-A2 Terminals: Volume di controllotage input (8-230V~).
- L-N Terminals: Power supply input (230V~).
- 3 Terminale: Switched output (max. 10A/250V~).
- RV Potentiometer: Adjustable delay on release timer (0-12 minutes).
- AV Potentiometer: Adjustable delay on activation timer (0-12 minutes).
4. Configurazione e installazione
The NLZ61NP-UC is designed for series installation within an electrical distribution board or similar enclosure.
Fasi di installazione:
- Disconnessione dell'alimentazione: Ensure the main power supply to the installation area is completely disconnected before beginning any work.
- Montaggio: Mount the timer relay securely in the desired location, typically on a DIN rail within a suitable enclosure.
- Wiring Power Supply (L-N): Connect the live (L) and neutral (N) wires of the 230V~ power supply to the corresponding L and N terminals on the device.
- Wiring Control Voltage (A1-A2): Collegare il controllo voltage (8-230V~) to the A1 and A2 terminals. This voltage triggers the timing functions.
- Wiring Output (3): Connect the load to be switched to the '3' terminal. The other side of the load should be connected to the neutral (N) or live (L) depending on the circuit design. Ensure the load's current and voltage requirements do not exceed 10A/250V~.
- Verifica connessioni: Double-check all wiring for correctness and security to prevent short circuits or malfunctions.
- Ripristina alimentazione: Una volta verificati tutti i collegamenti, ripristinare l'alimentazione al circuito.
5. Istruzioni per l'uso
The Eltako NLZ61NP-UC features two adjustable timing functions: delay on release (RV) and delay on activation (AV).
Setting the Timer Functions:
- RV (Delay on Release): Use the RV potentiometer to set the desired delay time after the control voltage (A1-A2) is removed. The output will remain active for the set duration before switching off. The range is 0 to 12 minutes.
- AV (Delay on Activation): Use the AV potentiometer to set the desired delay time after the control voltage (A1-A2) is applied. The output will activate after the set duration. The range is 0 to 12 minutes.
- Regolazione: Rotate the respective potentiometer (RV or AV) to align the indicator with the desired time value on the scale (0, 2, 4, 8, 12 minutes).
The specific behavior of the relay (e.g., which delay function is active or if both can be combined) depends on the internal configuration and application. Refer to the detailed wiring diagram provided with the product for specific operational modes.
6. Manutenzione
The Eltako NLZ61NP-UC Timer Relay is designed for long-term, maintenance-free operation under normal conditions.
- Pulizia: Se necessario, pulire delicatamente l'esterno del dispositivo con un panno asciutto e morbido. Non utilizzare detergenti abrasivi o solventi.
- Ispezione: Periodically inspect the wiring connections for any signs of loosening or damage. Ensure the device is free from dust and debris.
- Nessuna parte riparabile dall'utente: The device contains no user-serviceable parts. Do not attempt to open or repair the unit.
7. Risoluzione Dei Problemi
If the timer relay does not function as expected, consider the following common issues:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il dispositivo non risponde | No power supply (L-N) or control voltage (A1-A2). Incorrect wiring. | Check power supply and control voltage. Verify all wiring connections according to the diagram. |
| L'uscita non commuta | Load exceeding current/voltage rating. Incorrect timing setting. Faulty load. | Ensure load is within specifications. Adjust RV/AV potentiometers. Test the load independently. |
| Tempistica errata | Potentiometer set incorrectly. | Re-adjust the RV or AV potentiometer to the desired time. |
If problems persist, contact a qualified electrician or Eltako customer support.
8. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Marca | Eltako |
| Numero di modello | NLZ61NP-UC (also 2000614, 61100704) |
| Volume di controllotage (A1-A2) | 8-230V~ |
| Volume di eserciziotage (LN) | 230V~ |
| Rated Current (Output 3) | 10 A |
| Volume nominaletage (Uscita 3) | 250 Volt |
| Timing Range (RV, AV) | 0-12 minuti |
| Materiale | Plastica |
| Dimensioni (confezione) | Dimensioni: 8.9 x 6.5 x 2.2 cm |
| Peso dell'articolo | 40 grammi |
| Tipo di montaggio | Series installation |
| Modalità operativa | ON-OFF-ON (Rotary switch type) |
9. Garanzia e supporto
For warranty information and technical support, please refer to the documentation provided with your purchase or contact Eltako customer service directly. Keep your proof of purchase for warranty claims.