The Leviton 8215-PLC is a 15 Amp, 125 Volt, NEMA 5-15P, 2-pole, 3-wire, straight blade grounding plug designed for hospital grade applications. This transparent plug features a power indication LED, allowing for visual confirmation of power presence. Constructed with a super tough nylon body and solid brass blades and contacts, it offers durability, superior conductivity, and resistance to impact, abrasion, and chemicals.

Leviton 8215-PLC Hospital Grade Plug

Image: The Leviton 8215-PLC Hospital Grade Plug, transparent with a green power indicator.

Informazioni sulla sicurezza

AVVERTIMENTO: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

Configurazione e installazione

This section provides instructions for properly wiring the Leviton 8215-PLC plug to a power cord. Ensure the power cord is appropriate for the intended application and current rating.

Strumenti necessari:

Istruzioni di cablaggio:

  1. Preparare il cavo: Carefully strip the outer jacket of your power cord to expose approximately 1.5 to 2 inches of the insulated wires (typically black, white, and green/bare copper). Then, strip about 1/2 inch of insulation from the ends of the black (hot), white (neutral), and green/bare copper (ground) wires.
  2. Smontare la spina: Unscrew the assembly screws on the plug body to separate the front and back sections. Slide the back cover and cord clamp components onto the power cord in the correct orientation.
  3. Collegare i fili: The Leviton 8215-PLC features internal wiring chambers designed to isolate individual conductors. Connect the wires to the appropriate terminals:
    • Green/Bare Copper Wire: Connettiti al verde (grounding) screw terminal.
    • filo bianco: Connettiti al argento (neutral) screw terminal.
    • Filo nero: Connettiti al ottone (hot) screw terminal.
    Ensure all wire strands are securely under the screw heads and tightened firmly. Trim any excess wire strands to prevent short circuits.
  4. Secure the Cord Clamp: Position the cord clamp around the power cord and tighten the screws to provide a secure grip without damaging the cord's outer jacket. This prevents strain on the wire connections.
  5. Rimontare la spina: Carefully align the front and back sections of the plug, ensuring no wires are pinched. Securely fasten the assembly screws.
Internal wiring chambers of the plug

Immagine: Primo piano view of the internal wiring chambers, showing isolated conductors and screw terminals.

Plug with cord clamp securing a cable

Image: The plug's cord clamp mechanism, designed to secure the power cord and prevent strain.

Istruzioni per l'uso

Once properly wired, the Leviton 8215-PLC plug is ready for use.

  1. Connettiti all'alimentazione: Insert the plug firmly into a compatible 125V, 15A NEMA 5-15R receptacle.
  2. Verify Power Indication: The long-life LED bulb on the transparent body of the plug will illuminate green when power is present at the device. This provides a quick visual confirmation that the circuit is live and the plug is receiving power.
  3. Disconnessione: To disconnect, grasp the plug body firmly and pull it straight out from the receptacle. Do not pull by the cord.

Manutenzione

Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 8215-PLC plug.

Risoluzione dei problemi

If you encounter issues with your Leviton 8215-PLC plug, refer to the following troubleshooting steps:

Specifiche

Numero di modello 8215-PLC
Amprabbia 15 Amps
Voltage 125 Volt
Configurazione NEMA dalle 5:15 alle XNUMX:XNUMX
Poli/fili Messa a terra a 2 poli e 3 fili
Grado del prodotto Grado ospedaliero
Materiale Super Tough Nylon (Body), Thermoplastic (Back Cover)
Colore Trasparente
Indicazione di potenza Lampadina LED
Approvazioni UL 498, CSA C22.2, NOM 057
Peso dell'articolo 0.01 once
Dimensioni del prodotto 9.38 x 7.13 x 9 pollici

Informazioni sulla garanzia

This Leviton product is covered by the manufacturer's limited lifetime warranty. For detailed information regarding warranty terms, conditions, and registration, please refer to the official Leviton website or contact Leviton customer service directly. Keep your proof of purchase for warranty claims.

Assistenza clienti

Per assistenza tecnica, richieste di informazioni sui prodotti o ulteriore supporto, visitare il sito ufficiale Leviton website or contact their customer service department. Contact information can typically be found on the Leviton websito o confezione del prodotto.

Levitone Websito: www.leviton.com

Documenti correlati - 8215-PLC

Preview Guida alla selezione degli interruttori Leviton di livello commerciale e industriale
Una guida completa alla selezione di Leviton che descrive in dettaglio gli interruttori di livello commerciale e industriale, tra cui interruttori a levetta, Decora Plus, Lev-lok, antimicrobici e speciali, con dettagli applicativi e schemi elettrici.
Preview Guida all'installazione e al collaudo della presa GFCI Leviton
Una guida completa su come installare e testare una presa GFCI Leviton SmartLock Pro, comprese istruzioni di cablaggio, precauzioni di sicurezza e suggerimenti per la risoluzione dei problemi.
Preview Leviton EV40P EV Serie 40 AMP Manuale di installazione del caricabatterie plug-in
Manuale di installazione per Leviton EV40P EV Series 40 AMP Caricabatterie plug-in per veicoli elettrici. Include avvertenze di sicurezza, specifiche, fasi di installazione, procedure operative, utilizzo della scheda RFID, messaggi di errore, informazioni sulla manutenzione e sulla garanzia.
Preview Manuale di installazione e funzionamento della presa GFCI Leviton con porte USB
Guida completa per l'installazione e il funzionamento delle prese GFCI Leviton con porte USB, comprese istruzioni di cablaggio, avvertenze di sicurezza, procedure di collaudo e informazioni sulla garanzia.
Preview Installazione e test della presa GFCI intelligente Leviton: una guida completa
Istruzioni dettagliate per l'installazione e il collaudo delle prese GFCI Leviton Smart (modelli D2GF1, D2GF2). Scopri di più sulla funzionalità GFCI, sul cablaggio, sulla risoluzione dei problemi e sulle precauzioni di sicurezza.
Preview Istruzioni per l'installazione del contenitore del centro di carico Leviton
Istruzioni di installazione dettagliate per i contenitori per centri di carico Leviton, modelli LP2xx, LP3xx, LP4xx e LP6xx. ...