The Leviton 15 Amp, 125 Volt, Straight Blade, Industrial Grade, Dustguard, Grounding Connector, Model 1547, is engineered for demanding environments. Its rugged construction resists impact, sunlight, chemicals, and rough use. Key features include solid one-piece contacts for superior conductivity and an ergonomic, fluted-body design with a radial gripping edge for easy handling. The unique cord clamp accommodates a wide range of cord sizes, ensuring a secure grip without damaging the cord. This connector is designed to meet IP44 splash-proof and dust-tight standards. The Santoprene Husk material provides resistance to oil, acids, alkalis, and many industrial solvents, and is developed to withstand dusty and dirty environments, cracking, fading, and temperature extremes.

Leviton 1547 Industrial Grade Straight Blade Grounding Connector

Image: Leviton 1547 Industrial Grade Straight Blade Grounding Connector, Yellow.

Informazioni importanti sulla sicurezza

ATTENZIONE: Rischio di scossa elettrica o incendio. This product must be installed and used in accordance with national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician. Always disconnect power at the circuit breaker or fuse box before installing or servicing this product. Do not use this product if it appears damaged. This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm (Proposition 65 warning).

Istruzioni per l'installazione

Follow these steps for proper wiring and assembly of the connector:

  1. Preparare il cavo: Strip the outer jacket of your electrical cable to the appropriate length, typically 1 to 1.5 inches, exposing the insulated conductors (hot, neutral, ground). Strip approximately 1/2 inch of insulation from each conductor.
  2. Smontare il connettore: Unscrew the housing of the Leviton 1547 connector to separate the body from the wiring module.
  3. Inserire il cavo: Thread the prepared cable through the cord clamp and into the connector body.
  4. Connessioni dei cavi: Connect the insulated conductors to the corresponding terminals on the wiring module.
    • Filo di rame verde o nudo: Connect to the grounding screw (green).
    • White Wire (Neutral): Connect to the silver screw.
    • Black Wire (Hot): Connect to the brass screw.
    Ensure all wire strands are securely under the screw heads and tightened firmly. Double-check that no stray wire strands are touching other terminals.
  5. Secure Cord Clamp: Stringere il cordone clamp screws to secure the cable, ensuring a firm grip without overtightening, which could damage the cord. The cord clamp prevents strain on the wire connections.
  6. Rimontare il connettore: Carefully align the wiring module with the connector body and screw the housing back together until it is tight. Ensure no wires are pinched during reassembly and that the connector is fully sealed.

Operazione

Once properly installed and assembled, the Leviton 1547 connector functions as a standard electrical plug. Insert the connector into a compatible 125 Volt, 15 Amp, straight blade receptacle (NEMA 5-15R) to establish an electrical connection. Ensure the connection is firm and secure. To disconnect, grasp the connector body and pull it straight out from the receptacle; do not pull by the cord.

Manutenzione

To ensure continued safe and reliable operation of your Leviton 1547 connector, perform the following maintenance:

Risoluzione dei problemi

If you encounter issues with your Leviton 1547 connector, refer to the following table for common problems and solutions:

ProblemaPossibile causaSoluzione
Nessuna alimentazione al dispositivo collegatoLoose wire connection inside the connector or at the receptacle.Disconnect power at the circuit breaker. Carefully disassemble the connector and re-check and tighten all wire connections. Ensure the receptacle is functioning correctly.
Connector feels hot during useOverload on the circuit, poor wire connection, or damaged connector.Immediately disconnect power. Ensure the connected device does not exceed the connector's 15 Amp rating. Inspect for loose connections or visible damage. If damage is present, replace the connector.
Connector does not fit into the receptacleIncompatible plug or receptacle type.Verify that the receptacle is a standard 125 Volt, 15 Amp, straight blade type (NEMA 5-15R). This connector is not designed for other receptacle types.
Visible damage to the connector (cracks, exposed wires)Physical stress, impact, or chemical exposure.Replace the connector immediately. Do not use damaged electrical equipment as it poses a severe safety risk.

Specifiche tecniche

CaratteristicaSpecificazione
MarcaLevitone
Numero di modello1547
Amprabbia15 Amps
Voltage125 Volt
Tipo di connettoreStraight Blade, Grounding
Tipo di spinaType B or Type NEMA 5-15
Numero di poli2
Number Of Wires3
Grado del prodottoIndustriale
MaterialeCopper (contacts), Santoprene Husk (body)
ColoreYellow (Multi)
Specifica MetNEMA, IP44 (Splash proof and dust-tight)

Garanzia e supporto

This Leviton product is backed by a Garanzia limitata di 10 anno. This warranty covers defects in materials and workmanship under normal use. For specific details regarding warranty coverage, limitations, and how to make a claim, please refer to the official Leviton websito o contattare direttamente il servizio clienti Leviton.

For technical assistance, product inquiries, or support, please visit the official Leviton webposto (www.leviton.com) or contact their customer support department. Contact information, including phone numbers and email addresses, can typically be found in the 'Support' or 'Contact Us' section of their websito.

Documenti correlati - 1547

Preview Guida all'app My Leviton: controlla i tuoi dispositivi Smart Home
Esplora la guida all'app My Leviton per registrare, integrare e personalizzare facilmente i tuoi dispositivi Decora Smart Wi-Fi e Leviton Load Center con Smart Breakers per un controllo della casa intelligente senza interruzioni.
Preview Guida alla selezione degli interruttori Leviton di livello commerciale e industriale
Una guida completa alla selezione di Leviton che descrive in dettaglio gli interruttori di livello commerciale e industriale, tra cui interruttori a levetta, Decora Plus, Lev-lok, antimicrobici e speciali, con dettagli applicativi e schemi elettrici.
Preview Leviton EV40P EV Serie 40 AMP Manuale di installazione del caricabatterie plug-in
Manuale di installazione per Leviton EV40P EV Series 40 AMP Caricabatterie plug-in per veicoli elettrici. Include avvertenze di sicurezza, specifiche, fasi di installazione, procedure operative, utilizzo della scheda RFID, messaggi di errore, informazioni sulla manutenzione e sulla garanzia.
Preview La mia guida all'app Leviton: controllo della casa intelligente per Decora Smart Wi-Fi e centri di carico
Una guida completa all'utilizzo dell'app My Leviton per la gestione dei dispositivi Leviton Decora Smart Wi-Fi e dei centri di carico Leviton con interruttori intelligenti. ...
Preview Software Leviton Building Manager Online (BMO) Oltreview
Scopri il software Building Manager Online (BMO) di Leviton, una soluzione di gestione energetica affidabile e basata su cloud per edifici commerciali. Esplora funzionalità come la visualizzazione dei consumi energetici, la fatturazione degli inquilini, la reportistica avanzata e gli strumenti di conformità alle normative, progettati per ottimizzare il consumo energetico e ridurre i costi operativi.
Preview La mia guida all'app Leviton: configurazione e controllo della casa intelligente
Guida completa al download, all'installazione e all'utilizzo dell'app My Leviton per la domotica, la gestione dei dispositivi, le attività, le pianificazioni e la modalità appaltatore. Impara a connettere i dispositivi, creare scenari personalizzati e gestire la tua casa intelligente.