1. Introduzione
The Aiphone AX-8MV is an audio/video master station designed for the AX Series integrated security system. It serves as a central communication and monitoring unit, allowing connection to multiple master stations, door stations, and sub-master stations. This manual provides essential information for the proper setup, operation, and maintenance of your AX-8MV unit.
2. Configurazione e installazione
2.1. Cosa c'è nella scatola
- Aiphone AX-8MV Master Station
- Staffa di montaggio in metallo
- Supporto girevole
2.2. Opzioni di montaggio
The AX-8MV offers flexible installation. Use the included flip stand for convenient desk mounting. For wall installation, utilize the metal mounting bracket to secure the unit to a standard two-gang box or ring.
2.3. Cablaggio e alimentazione
The master station requires Cat-5e homerun wiring to the Central Exchange Unit (CEU) via an RJ45 jack. Power is supplied by the Aiphone central exchange unit (sold separately) at 24V.
3. Istruzioni per l'uso

This image displays the Aiphone AX-8MV Audio/Video Master Station. The unit features a central 3.5-inch LCD color monitor showing a person's face, flanked by two columns of call buttons with LED indicators. Below the screen are control buttons for functions such as Privacy, CO Transfer, Scan Monitor, Off, All Call, and Talk, with a prominent red Talk button.
3.1. Comunicazione di base
- Chiamate in arrivo: When an incoming call is received from an Aiphone AX Series video door station (sold separately), the 3-1/2" LCD color monitor will immediately display the video feed, assisting with visitor identification.
- Rispondere alle chiamate: To answer a call, either hold down the answering button for push-to-talk communication or tap the answering button for hands-free communication.
- Volume del tono di chiamata: The call tone volume is adjustable to suit your preference.
3.2. System Controls
- Labeled Buttons: Each master, sub-master, and door station connected to the system has its own labeled button on the master station, enabling selectable and direct calling. An LED indicator on each button shows which station is currently calling.
- All-Call Button: Press the all-call button to broadcast an announcement to every master station connected within the system.
- Pulsante Privacy: Activate the privacy button to prevent other intercom users in the system from overhearing your conversation with another intercom.
3.3. Sblocco porta
The door-release button on the AX-8MV works in conjunction with an electric strike or magnetic lock (sold separately) to remotely unlock the entrance for a visitor.
3.4. Connessioni esterne
- Headset/Handset/Speaker: A 3.5-mm jack is provided for connecting a headset, handset, or external speaker (sold separately).
- Interruttore a pedale: A footswitch (sold separately) can be attached for hands-free operation of the master station.
- Chiamate da rete fissa: Calls can be routed directly to a landline phone through the use of a Viking K-1900-5 callswitch (sold separately).
4. Espansione del sistema
The AX Series system can be expanded significantly. Up to seven Aiphone AX-16SW selectors (sold separately) can be integrated to connect a total of 112 additional sub-master or door stations, allowing for comprehensive building-wide security and communication.
5. Manutenzione
To ensure optimal performance and longevity of your Aiphone AX-8MV master station, follow these maintenance guidelines:
- Pulizia: Regularly wipe the unit's black ABS plastic housing and screen with a soft, dry cloth. Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the surface and electronic components.
- Ambiente: Assicurarsi che l'unità sia installata in un ambiente asciutto, lontano dalla luce solare diretta, da temperature estreme e da polvere eccessiva.
- Ispezioni: Controllare periodicamente tutti i collegamenti elettrici per accertarsi che siano sicuri e privi di danni.
6. Risoluzione Dei Problemi
If you encounter issues with your AX-8MV master station, consider the following common troubleshooting steps:
- Nessun potere: If the unit does not power on, ensure the Aiphone central exchange unit is properly connected and supplying the required 24V. Check all power connections.
- Unclear Communication: If audio communication is unclear or intermittent, verify that all Cat-5e homerun wiring to the CEU and RJ45 jack connections are secure and undamaged.
- Nessun feed video: If the video feed from a door station is not displayed, confirm that the video door station is correctly installed, powered, and properly connected to the AX Series system. Check for any loose video cables.
- Pulsanti che non rispondono: If buttons are not responding, try restarting the entire AX Series system by cycling power to the central exchange unit. If the issue persists, contact technical support.
7. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Dimensioni complessive (A x L x P) | 6-7/8 x 7-5/8 x 1-7/8 pollici (175 x 194 x 48 mm) |
| Cablaggio compatibile | Cat-5e homerun to CEU |
| Collegamento del cablaggio | Presa RJ45 |
| Requisiti di potenza | 24V supplied by Aiphone central exchange unit (sold separately) |
| Materiale dell'alloggiamento | Plastica ABS nera |
| Monitor | 3-1/2" LCD color |
8. Garanzia e supporto
Aiphone is committed to quality and reliability, meeting International Organization for Standardization (ISO) standards 9001 and 14001. For specific warranty details, technical assistance, or customer support, please refer to the official Aiphone webo contattare il rivenditore Aiphone autorizzato. Conservare la ricevuta d'acquisto per eventuali reclami in garanzia.