Introduzione e informazioni sulla sicurezza
This manual provides essential instructions for the safe installation, operation, and maintenance of your Oasis PG8ACSL Versa II Water Cooler. Please read all instructions carefully before installation and use to ensure proper function and to prevent injury or damage.
Prodotto finitoview
- The Oasis PG8ACSL is a split-level, refrigerated water cooler designed for durability and efficiency.
- Constructed from heavy-gauge galvanized steel with a stainless steel top and finish.
- Features energy and water conservation technology, including mechanically activated push pads and a water-saver bubbler.
- Equipped with a high-efficiency cooling system using R-134a refrigerant, delivering 8.0 gallons of chilled drinking water per hour.
- Includes a built-in 100-micron strainer to filter particles from the waterway.
- Designed to be ADA compliant when properly installed, ensuring accessibility.
- cUL listed and NSF/ANSI Standard 61, Annex G certified, ensuring quality and safety.
- Waterways are lead-free in materials and construction.
Importanti istruzioni di sicurezza
- Scollegare sempre l'alimentazione prima di effettuare qualsiasi intervento di assistenza o manutenzione.
- Assicurare una corretta messa a terra per evitare scosse elettriche.
- Non utilizzare l'unità se il cavo di alimentazione è danneggiato.
- Installation must comply with all local plumbing and electrical codes.
- Mantenere le aperture di ventilazione libere da ostruzioni.
Configurazione e installazione
Proper installation is crucial for the performance and longevity of your water cooler. It is recommended that installation be performed by a qualified plumber and electrician.
Disimballaggio e ispezione
- Estrarre con cautela il refrigeratore d'acqua dalla confezione.
- Ispezionare l'unità per verificare la presenza di eventuali danni causati dal trasporto. Segnalare immediatamente eventuali danni al fornitore.
- Ensure all components, including any plumbing tools, are present.
Requisiti di posizione
- Install on a sturdy, level surface capable of supporting the unit's weight (approximately 64 lbs).
- Garantire uno spazio adeguato attorno all'unità per la ventilazione e l'accesso per la manutenzione.
- Locate near a suitable cold water supply line and a drain.
- Ensure a properly grounded 120VAC, 4.4 Amp electrical outlet is available.
Collegamento idraulico
- Turn off the main water supply before beginning plumbing work.
- Connect the water supply line to the inlet connection on the water cooler. Refer to local plumbing codes for specific requirements.
- Assicurarsi che tutte le connessioni siano sicure e prive di perdite.
- Prima di collegare l'unità, sciacquare accuratamente le condutture dell'acqua per rimuovere eventuali detriti.
Connessione elettrica
- Ensure the electrical supply matches the unit's requirements (120VAC, 4.4 AmpS).
- Plug the polarized plug into a dedicated, properly grounded electrical outlet.
- Non utilizzare prolunghe o adattatori.
Controlli finali
- Verificare che l'unità sia livellata e stabile.
- Check for any leaks in the plumbing connections.
- Ensure side and front panels are securely in place after installation, as they provide access for maintenance.
- Confirm ADA compliance for proper height and clear floor space if applicable.

Immagine: Frontale view of the Oasis PG8ACSL Versa II Water Cooler, showcasing its stainless steel finish and dual-level design.
Istruzioni per l'uso
The Oasis PG8ACSL water cooler is designed for simple and reliable operation.
Erogazione dell'acqua
- Once the unit is properly installed and connected to power and water, it will begin chilling water. Allow approximately 30 minutes for the water to reach optimal cold temperature.
- To dispense water, press either the front or side push pad. The bubbler will activate, providing a stream of water.
- Release the push pad to stop the water flow.

Image: A person using the Oasis PG8ACSL water cooler, demonstrating the activation of the bubbler by pressing the side push pad.
Adjusting Stream Height
The water stream height can be adjusted externally. Locate the stream height adjustment screw, typically near the bubbler, and turn it clockwise to decrease the stream height or counter-clockwise to increase it. Adjust as needed to prevent splashing and ensure comfortable use.
Manutenzione
Regular maintenance ensures optimal performance and extends the life of your Oasis water cooler. Always disconnect power before performing maintenance.
Pulizia dell'esterno
- Wipe down the stainless steel exterior and basin regolarmente con un morbido, damp panno e sapone neutro.
- Evitare detergenti abrasivi o pagliette abrasive, che possono danneggiare la finitura.
- Ensure the fountain basin is kept clean to eliminate standing water and prevent mineral buildup.
Strainer Cleaning
The unit features a built-in 100-micron strainer to prevent particles from entering the waterway. Periodically, this strainer may need cleaning, especially if water flow decreases.
- Chiudere l'alimentazione dell'acqua all'unità.
- Scollegare l'alimentazione elettrica.
- Access the strainer, typically located near the water inlet. Refer to the unit's internal diagrams if necessary (access may require removing side or front panels).
- Remove and rinse the strainer under clean running water to clear any accumulated debris.
- Reinstall the strainer, reconnect water and power, and check for leaks.
Pulizia della batteria del condensatore
The condenser coils should be cleaned annually or more frequently in dusty environments to maintain cooling efficiency. Access to the coils typically requires removing the side or front panels.
- Scollegare l'alimentazione dall'unità.
- Remove the appropriate panels to access the condenser coils.
- Use a brush or vacuum cleaner to gently remove dust and lint from the coils.
- Replace panels and reconnect power.
Risoluzione dei problemi
This section addresses common issues you might encounter with your water cooler. For problems not listed here, contact customer support.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Nessun flusso d'acqua o flusso d'acqua basso |
|
|
| Water not cold |
|
|
| Water splashing or spilling |
|
|
| L'unità emette un rumore insolito |
|
|
Specifiche
| Numero di modello | PG8ACSL |
| Marca | Oasi |
| Colore/Finitura | Acciaio inossidabile |
| Capacità | 8 galloni all'ora (GPH) |
| Dimensioni (P x L x A) | 18.63" x 34.25" x 24.91" |
| Peso dell'articolo | 64 libbre |
| Tipo di installazione | piombato |
| Fonte di alimentazione | Elettricità |
| Voltage | 120 V CA |
| Amprabbia | 4.4 Amps |
| Refrigerante | R-134a |
| Conformità | ADA Compliant (when properly installed), cUL Listed, NSF/ANSI Standard 61 Annex G Certified |
| Codice UPC | 092026168871, 092026168864 |
Informazioni sulla garanzia
Oasis provides a limited 5-year warranty for the PG8ACSL Versa II Water Cooler. This warranty covers defects in materials and workmanship under normal use and service. For specific terms, conditions, and to register your product, please refer to the warranty card included with your purchase or visit the official Oasis websito.
Assistenza clienti
If you require assistance with installation, operation, maintenance, or troubleshooting beyond the scope of this manual, please contact Oasis customer support.
- Supporto online: Visit the official Oasis websito per FAQ, documentazione sui prodotti e moduli di contatto.
- Servizio tecnico: For technical inquiries or service requests, please refer to the contact information provided on the Oasis websito o la documentazione di acquisto.
When contacting support, please have your model number (PG8ACSL) and serial number ready.