Leviton 5266-B

Levitone 15 Amp, 125 Volt, lama dritta, spina di messa a terra di livello industriale (modello 5266-B) Manuale di istruzioni

Modello: 5266-B

Introduzione

This manual provides detailed instructions for the safe and proper installation and use of the Leviton 15 Amp, 125 Volt, Straight Blade, Industrial Grade Grounding Plug, Model 5266-B. This device is designed for reliable performance in demanding environments.

Leviton 5266-B Industrial Grade Grounding Plug

Image: Leviton 15 Amp, 125 Volt, Straight Blade, Industrial Grade Grounding Plug (Model 5266-B).

Informazioni importanti sulla sicurezza

WARNING: Shock Hazard. To avoid risk of serious injury or death, turn power off at the circuit breaker before wiring any electrical device.

Configurazione e installazione

This section details the steps required to properly wire the Leviton 5266-B plug to an electrical cable.

Strumenti necessari:

Procedura di cablaggio:

  1. Preparare la spina:

    Using a Phillips head screwdriver, loosen the quick-release screws on the faceplate of the plug. Carefully remove the faceplate from the body housing.

  2. Preparare il cavo:

    Loosen the two strain relief screws on the plug's body housing. Feed the electrical cable through the strain relief and into the body housing. Strip the cord jacket according to the diagram provided in the instruction sheet (typically 1.5 inches). Remove the cord jacket to expose the individual wires.

  3. Trim the Ground Wire:

    The green (ground) wire needs to be approximately 1 inch long. Use wire strippers to cut the green wire to the appropriate length.

  4. Strip Individual Wires:

    Strip approximately 5/8 inch of insulation from all individual wires (green, white, and any hot wires). Twist the strands of each wire tightly to prevent fraying.

  5. Collegare il filo di terra:

    Loosen the green ground screw located in the center of the faceplate. Insert the stripped green (ground) wire into the wire well of the green terminal. Tighten the terminal screw securely.

  6. Collegare il filo neutro:

    Loosen the silver terminal screw. Insert the stripped white (neutral) wire into the wire well of the silver terminal. Tighten the terminal screw securely.

  7. Connect Hot Wires:

    Loosen the brass terminal screws. Insert the remaining stripped wires (hot wires, typically black or red) into the wire wells of the brass terminals. Tighten the terminal screws securely.

  8. Rimontare la spina:

    Align the channel guide on the body housing with the faceplate. Slide the faceplate into the body housing. Using a Phillips head screwdriver, tighten the quick-release screws on the faceplate to secure it to the body housing.

  9. Tighten Strain Relief:

    Tighten both screws on the strain relief to secure the cable and prevent tension on the internal wiring connections.

  10. Note for Larger Wires:

    If your cable is larger than the groove on the strain relief, a section of the strain relief can be removed to accommodate larger wire gauges.

Video di installazione:

For a visual guide on wiring the Leviton Black and White Plug and Connector, please refer to the video below:

Video: Instructions on how to wire a Leviton Black and White Plug and Connector. This video demonstrates the step-by-step process of disassembling the plug, preparing the cable, connecting the ground, neutral, and hot wires, and reassembling the device, including tightening the strain relief.

Istruzioni per l'uso

Once properly wired and assembled, the Leviton 5266-B plug is ready for use. Insert the plug into a compatible 125V, 15 Amp receptacle. Ensure a secure connection. This industrial-grade plug is designed for demanding applications, providing reliable power transmission.

Manutenzione

Risoluzione dei problemi

ProblemaPossibile causaSoluzione
Nessuna alimentazione al dispositivo collegatoLoose wire connection; tripped circuit breaker; faulty receptacle.Check all wire connections inside the plug. Reset the circuit breaker. Test the receptacle with another known working device.
Plug feels hot during useOverload; loose connection; damaged wire.Reduce load on the circuit. Check for loose connections. Inspect wires for damage. Discontinue use if overheating persists.
Cable pulls out of plugLoose strain relief.Tighten the strain relief screws securely.

Specifiche

Garanzia e supporto

This Leviton product is covered by a manufacturer's warranty. For specific warranty details, claims, or technical support, please refer to the official Leviton website or contact their customer service directly. Keep your purchase receipt for warranty purposes.

Per maggiori informazioni, visita il Negozio Leviton su Amazon.

Documenti correlati - 5266-B

Preview Guida all'installazione e al collaudo della presa GFCI Leviton
Una guida completa su come installare e testare una presa GFCI Leviton SmartLock Pro, comprese istruzioni di cablaggio, precauzioni di sicurezza e suggerimenti per la risoluzione dei problemi.
Preview Leviton EV40P EV Serie 40 AMP Manuale di installazione del caricabatterie plug-in
Manuale di installazione per Leviton EV40P EV Series 40 AMP Caricabatterie plug-in per veicoli elettrici. Include avvertenze di sicurezza, specifiche, fasi di installazione, procedure operative, utilizzo della scheda RFID, messaggi di errore, informazioni sulla manutenzione e sulla garanzia.
Preview Manuale di installazione e funzionamento della presa GFCI Leviton con porte USB
Guida completa per l'installazione e il funzionamento delle prese GFCI Leviton con porte USB, comprese istruzioni di cablaggio, avvertenze di sicurezza, procedure di collaudo e informazioni sulla garanzia.
Preview Installazione e test della presa GFCI intelligente Leviton: una guida completa
Istruzioni dettagliate per l'installazione e il collaudo delle prese GFCI Leviton Smart (modelli D2GF1, D2GF2). Scopri di più sulla funzionalità GFCI, sul cablaggio, sulla risoluzione dei problemi e sulle precauzioni di sicurezza.
Preview Istruzioni per l'installazione del contenitore del centro di carico Leviton
Istruzioni di installazione dettagliate per i contenitori per centri di carico Leviton, modelli LP2xx, LP3xx, LP4xx e LP6xx. ...
Preview Catalogo Leviton L-100: Dispositivi di cablaggio e controlli di illuminazione per edilizia e manutenzione
Esplora l'ampio catalogo Leviton L-100, che offre una vasta selezione di dispositivi di cablaggio, sistemi di controllo dell'illuminazione e soluzioni elettriche di alta qualità per applicazioni industriali, commerciali e residenziali. Scopri il secolo di innovazione e l'impegno di Leviton per la qualità.