Leviton 24W49

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug

Model 24W49 Instruction Manual

1. Prodotto finitoview

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is a robust wiring device designed for demanding industrial environments. This plug features a polarized, grounding, L6-15P configuration with 3 wires, rated for 250V AC and 15 Amps. It is constructed from EPTR rubber material in a yellow color, ensuring water-tight performance and resistance to various harsh conditions. The Wetguard line meets IP67 and NEMA ratings for water ingress protection, offering superior durability and reliability.

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug, Model 24W49

Figure 1: Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49)

2. Caratteristiche principali

  • Industrial Grade Construction: Built to withstand harsh industrial environments.
  • Watertight and Dust-tight: Meets IP67 and NEMA ratings for protection against water and dust ingress.
  • Materiale durevole: Made from EPTR rubber, resistant to water, acids, alkalis, lubricants, cleaners, and solvents.
  • Resistenza alla corrosione: Blades, contacts, terminal screws, and wiring clamps are electroless nickel-coated brass.
  • Cablaggio semplice: Deep wire wells in the wiring module facilitate easier wiring.
  • Ispezione visiva: Clear housing aids in inspecting for proper wire insertion and connection.
  • Connessione sicura: Patented compression nut and strain relief system ensure integrity of both the watertight seal and electrical connection.
  • Configurazione: L6-15P, 2-pole, 3-wire grounding.
  • Certificazioni: UL 498, CSA C22.2, NOM 057 approved.

3. Specifiche

SpecificazioneValore
Numero di modello24W49
Amprabbia15 Amps
Voltage250 Volt
Formato plugType A (L6-15P)
Numero di fili3
Numero di poli2
Messa a terra
MaterialeEPTR Rubber
ColoreGiallo
Compatibilità delle dimensioni del cavoDa 0.234 a 0.687 pollici
Dimensioni del prodotto1.44 x 1.3 x 3.54 pollici
Peso dell'articolo3.2 once
CertificazioniUL 498, CSA C22.2, NOM 057

4. Informazioni sulla sicurezza

Always follow local electrical codes and regulations when installing or servicing electrical devices. Improper installation or use can result in serious injury or death. Disconnect power at the circuit breaker or fuse box before working on any electrical wiring.

  • Ensure the power supply is OFF before installation or maintenance.
  • Utilizzare dispositivi di protezione individuale (DPI) adeguati, come occhiali di sicurezza e guanti isolanti.
  • Verify correct wiring polarity and grounding connections.
  • Non superare il volume specificatotage e amperage ratings of the device.
  • Keep the device clean and free from debris to maintain its watertight integrity.
  • If the device shows signs of damage, discontinue use and replace it immediately.

5. Installazione

This section outlines the general steps for wiring the Leviton Wetguard Locking Plug. For detailed wiring diagrams and specific instructions, refer to the packaging or consult a qualified electrician.

  1. Preparare il cavo: Strip the outer jacket of the cable to the appropriate length, exposing the insulated conductors. Strip the insulation from each conductor.
  2. Smontare la spina: Unscrew the compression nut and separate the plug housing components.
  3. Inserire il cavo: Feed the prepared cable through the compression nut and into the plug housing.
  4. Connessioni dei cavi: Connect the conductors to the appropriate terminal screws. The clear housing allows for visual verification of proper wire insertion. Ensure all connections are tight and secure.
  5. Montare la spina: Reassemble the plug housing, ensuring the internal components are correctly aligned. Tighten the compression nut to create a watertight seal and engage the strain relief system.
  6. Verificare: Double-check all connections and ensure the plug is securely assembled before restoring power.

6. Funzionamento

The Leviton Wetguard Locking Plug is designed for secure and reliable electrical connections in wet or dusty environments. To operate:

  1. Collegare: Align the blades of the locking plug with the corresponding slots on a compatible locking receptacle.
  2. Gira per bloccare: Insert the plug fully and twist it clockwise until it locks into place. This action creates a secure mechanical and electrical connection, preventing accidental disconnection.
  3. Disconnetti: Per scollegare, ruotare la spina in senso antiorario per sbloccarla, quindi estrarla dalla presa.

The watertight design ensures safe operation even when exposed to moisture, provided the connection is properly mated and sealed.

7. Manutenzione

Regular maintenance helps ensure the longevity and safe operation of your Leviton Wetguard Locking Plug.

  • Ispezione periodica: Visually inspect the plug and cable for any signs of wear, cuts, cracks, or discoloration. Check for loose connections or corrosion on the blades.
  • Pulizia: Clean the exterior of the plug with a damp cloth. Avoid using harsh chemicals or abrasive cleaners that could damage the rubber material. Ensure the plug is dry before use.
  • Magazzinaggio: When not in use, store the plug in a clean, dry environment to prevent damage and prolong its lifespan.
  • Integrità del sigillo: Periodically check the integrity of the compression nut and strain relief system to ensure the watertight seal is maintained.

8. Risoluzione Dei Problemi

If you encounter issues with your Leviton Wetguard Locking Plug, consider the following common troubleshooting steps:

  • Nessun potere:
    • Check the power source (circuit breaker, fuse).
    • Ensure the plug is fully inserted and locked into the receptacle.
    • Ispezionare il cavo per danni.
  • Collegamento allentato:
    • Ensure the plug is twisted and locked securely.
    • If the internal wiring feels loose, disconnect power and re-check the terminal screw connections as per installation instructions.
  • Ingresso d'acqua:
    • Verify that the compression nut is tightly secured.
    • Inspect the rubber housing for any cracks or damage that could compromise the seal.

If the problem persists after attempting these steps, contact Leviton customer support or a qualified electrician.

9. Related Product Information (Video)

Il seguente video fornisce una panoramicaview of the Leviton Wetguard line of watertight wiring devices, showcasing their features and applications in various industrial environments. While the video may feature different models within the Wetguard series, the core principles of durability, watertight sealing, and robust construction apply to the 24W49 locking plug.

Video: Oltreview of Leviton Wetguard Watertight Wiring Devices

10. Garanzia e supporto

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the product packaging or visit the official Leviton websito.

For technical assistance, product inquiries, or support, please contact Leviton Customer Service:

  • Websito: www.leviton.com
  • Assistenza clienti: Fare riferimento al websito per informazioni di contatto regionali.

Documenti correlati - 24W49

Preview Guida alla selezione degli interruttori Leviton di livello commerciale e industriale
Una guida completa alla selezione di Leviton che descrive in dettaglio gli interruttori di livello commerciale e industriale, tra cui interruttori a levetta, Decora Plus, Lev-lok, antimicrobici e speciali, con dettagli applicativi e schemi elettrici.
Preview Guida all'installazione e al collaudo della presa GFCI Leviton
Una guida completa su come installare e testare una presa GFCI Leviton SmartLock Pro, comprese istruzioni di cablaggio, precauzioni di sicurezza e suggerimenti per la risoluzione dei problemi.
Preview Leviton EV40P EV Serie 40 AMP Manuale di installazione del caricabatterie plug-in
Manuale di installazione per Leviton EV40P EV Series 40 AMP Caricabatterie plug-in per veicoli elettrici. Include avvertenze di sicurezza, specifiche, fasi di installazione, procedure operative, utilizzo della scheda RFID, messaggi di errore, informazioni sulla manutenzione e sulla garanzia.
Preview Manuale di installazione e funzionamento della presa GFCI Leviton con porte USB
Guida completa per l'installazione e il funzionamento delle prese GFCI Leviton con porte USB, comprese istruzioni di cablaggio, avvertenze di sicurezza, procedure di collaudo e informazioni sulla garanzia.
Preview Installazione e test della presa GFCI intelligente Leviton: una guida completa
Istruzioni dettagliate per l'installazione e il collaudo delle prese GFCI Leviton Smart (modelli D2GF1, D2GF2). Scopri di più sulla funzionalità GFCI, sul cablaggio, sulla risoluzione dei problemi e sulle precauzioni di sicurezza.
Preview Istruzioni per l'installazione del contenitore del centro di carico Leviton
Istruzioni di installazione dettagliate per i contenitori per centri di carico Leviton, modelli LP2xx, LP3xx, LP4xx e LP6xx. ...