This manual provides instructions for the proper installation, operation, and maintenance of the Mars 33490 Heat Pump Defrost Thermostat. This device is designed to manage the defrost cycle of heat pump systems, ensuring efficient operation by sensing the temperature of the outdoor coil.

2. Caratteristiche del prodotto

  • Designed specifically for heat pump defrost applications.
  • Features a 3/8 inch tube mounting mechanism for secure attachment.
  • Equipped with 54 inch leads for flexible and convenient wiring.
  • Activates (opens) at approximately 80°F (26.7°C) to terminate defrost.
  • Deactivates (closes) at approximately 30°F (-1.1°C) to initiate defrost.

3. Informazioni sulla sicurezza

Importanti istruzioni di sicurezza

Read all instructions carefully before installation or operation. Failure to follow these instructions could result in property damage, personal injury, or death.

  • Always disconnect power to the heat pump system at the circuit breaker before installing or servicing the thermostat.
  • Installation should be performed by a qualified HVAC technician or licensed electrician to ensure safety and proper function.
  • Assicurarsi che tutti i cablaggi siano conformi ai codici e alle normative elettriche locali.
  • Do not operate the heat pump system if the thermostat or any associated components are visibly damaged.
  • This product may be subject to California Proposition 65. For more information, visit www.P65Warnings.ca.gov. Lavarsi le mani dopo la manipolazione.

4. Configurazione e installazione

Guida all'installazione

The Mars 33490 defrost thermostat is designed for secure mounting on a 3/8 inch diameter tube within the heat pump system.

  1. Disconnessione dell'alimentazione: Before commencing any work, ensure the main power supply to the heat pump unit is completely disconnected at the circuit breaker to prevent electrical shock.
  2. Posizione di montaggio: Identify a suitable 3/8 inch diameter tube on the heat pump's outdoor coil. This location should accurately reflect the coil's temperature for effective defrost control.
  3. Montaggio del termostato: Securely attach the thermostat to the selected 3/8 inch tube using its integrated mounting clip. Ensure there is good thermal contact between the thermostat's sensor and the tube for accurate temperature readings.
  4. Cablaggio: Connect the 54 inch leads of the thermostat into the heat pump's control circuit. Refer to the heat pump manufacturer's specific wiring diagram for correct connections. Typically, this thermostat is wired in series with the defrost control board's sensor input.
  5. Verifica connessioni: Double-check all wiring connections to ensure they are secure and correctly terminated according to the wiring diagram.
  6. Ripristina alimentazione: Once installation is complete and all connections have been verified, safely restore power to the heat pump system.
Mars 33490 Heat Pump Defrost Thermostat with 3/8 inch tube mount and wiring leads
Image 1: Mars 33490 Heat Pump Defrost Thermostat. This image shows the compact design of the thermostat, featuring its white cylindrical body, copper-colored base, metal mounting clip, and black electrical leads. The 3/8 inch tube mount is visible, designed for secure attachment to a heat pump's refrigerant line.
Lato view of Mars 33490 Heat Pump Defrost Thermostat showing wiring and mounting clip
Immagine 2: Lato view of the Mars 33490 Heat Pump Defrost Thermostat. This perspective highlights the robust metal mounting clip that secures the thermostat to a refrigerant tube, along with the entry point of the black wiring leads into the thermostat body. The product identification numbers are faintly visible on the white casing.

5. Funzionamento

Operazione funzionale

The Mars 33490 is an automatic defrost thermostat that operates by sensing the temperature of the outdoor coil. It functions as follows:

  • When the coil temperature rises to approximately 80°F (26.7°C), the thermostat's internal switch will open. This signal typically indicates that the coil is clear of ice and signals the defrost cycle to terminate.
  • When the coil temperature drops to approximately 30°F (-1.1°C), the thermostat's internal switch will close. This action initiates or allows the defrost cycle to begin, provided other defrost conditions (e.g., time, pressure differential) are met by the heat pump's main control board.

This thermostat works in conjunction with the heat pump's main control board to ensure efficient defrosting, preventing excessive ice buildup on the outdoor coil and maintaining optimal heating efficiency.

6. Manutenzione

Linee guida per la manutenzione

The Mars 33490 Defrost Thermostat is designed for reliable, long-term operation and is generally maintenance-free. However, periodic inspection is recommended to ensure continued optimal performance.

  • Ispezione annuale: During routine heat pump maintenance, visually inspect the thermostat for any signs of physical damage, corrosion, or loose wiring connections.
  • Pulizia: Ensure the area around the thermostat is kept free from debris, dirt, leaves, or ice buildup that could interfere with accurate temperature sensing.
  • Montaggio sicuro: Verify that the thermostat remains securely mounted to the refrigerant tube to maintain proper thermal contact and accurate temperature readings.

If any damage is observed, or if the heat pump exhibits unusual defrost behavior (e.g., no defrost, continuous defrost), consult a qualified HVAC technician for diagnosis and repair.

7. Risoluzione Dei Problemi

Risoluzione dei problemi comuni

This section provides general guidance for common issues related to defrost thermostat operation. Always consult a qualified technician for complex diagnostics and repairs, especially when dealing with electrical components.

ProblemaPossibile causaSoluzione
Heat pump not defrostingDefrost thermostat failure (stuck open circuit)A qualified technician should test thermostat continuity. Replace if faulty.
Heat pump defrosts too frequently or infrequentlyImproper thermostat mounting, poor thermal contact, or faulty thermostatVerify secure mounting and good thermal contact with the refrigerant tube. A technician can test thermostat operation and replace if necessary.
Thermostat appears physically damagedPhysical impact, environmental exposure, or wearDisconnect power and replace the thermostat immediately to prevent further system issues.

8. Specifiche

Specifiche tecniche

  • Modello: Marte 33490
  • Produttore: Marte
  • Numero parte: 33490
  • Open Temperature: 80°F (26.7°C)
  • Close Temperature: 30°F (-1.1°C)
  • Tipo di montaggio: 3/8 inch Tube Mount
  • Lunghezza del cavo: 54 pollici
  • Dimensioni del prodotto: Circa 5 x 3 x 2 pollici (12.7 x 7.6 x 5.1 cm)
  • Peso dell'articolo: Circa 4 once (113 grammi)
  • Batterie richieste: NO
  • Data prima disponibilità: 20 maggio 2010

9. Garanzia e supporto

Informazioni sulla garanzia e assistenza clienti

For specific warranty details regarding your Mars 33490 Heat Pump Defrost Thermostat, please refer to the documentation provided with your original purchase or contact Mars customer support directly.

For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact your authorized Mars dealer or visit the official Mars websito per le risorse di supporto.

Produttore: Marte

Numero parte: 33490

ASIN: B003N6AB98

Documenti correlati - 33490

Preview MARS SGF80S120D5S1A Single-StagElenco dei componenti della caldaia a gas multiposizione
Elenco ufficiale delle parti per MARS SGF80S120D5S1A Single-Stage Forno a gas multiposizione. Questo documento descrive in dettaglio i componenti, i nomi delle parti e le quantità per il forno AFUE 80% serie SE.
Preview Catalogo accessori WSHP geotermici e commerciali MARS
Questo catalogo di MARS descrive dettagliatamente gli accessori per sistemi di pompe di calore geotermiche e commerciali ad acqua (WSHP), tra cui vari centri di flusso, pompe di circuito, raccordi, utensili, controlli e kit di tubi flessibili progettati per un funzionamento efficiente e affidabile.
Preview Manuale di installazione e utilizzo del comando filaire MARS 7800-500
Guida completa per l'installazione e l'utilizzo del comando filaire MARS modello 7800-500. Scopri le procedure di installazione, le caratteristiche, le funzioni e le consegne di sicurezza per il tuo sistema CVC.
Preview Catalogo di assistenza e installazione MARS HVAC/R
Esplora l'ampio catalogo MARS di prodotti per l'installazione e la manutenzione di impianti HVAC/R. Trova componenti essenziali come staffe di montaggio per condizionatori, piastre per condensatori, kit di ventilazione, scatole di derivazione e molto altro, progettati per un'installazione professionale e prestazioni affidabili.
Preview Serie acqua-acqua MARS 24 (MW): Manuale di installazione, funzionamento e manutenzione
Guida completa per la serie MARS 24 (MW) acqua-acqua, che copre le procedure di installazione, funzionamento e manutenzione per applicazioni commerciali. Include nomenclatura dei modelli, avvertenze di sicurezza, manutenzione del sistema refrigerante, dati fisici e risoluzione dei problemi.
Preview Manuale d'uso del condizionatore d'aria inverter a scarico laterale a zona singola MARS Hyper Heat
Manuale utente completo per il condizionatore d'aria inverter a scarica laterale monozona MARS Hyper Heat. Include precauzioni di sicurezza, condizioni operative, manutenzione, risoluzione dei problemi e dettagli sulla garanzia per i modelli VCD24, 30, 36, 48 e 60 SA Series.