Altronix ACM8

Altronix ACM8 Access Power Controller 8 Fused Trigger

Manuale di istruzioni

1. Introduzione

The Altronix ACM8 Access Power Controller is designed to manage power distribution for access control systems. This unit features eight individually fused trigger outputs, providing reliable power and protection for various access control devices. It is suitable for a range of applications requiring controlled power distribution.

2. Prodotto finitoview

The ACM8 is a versatile power distribution board, ideal for integrating with access control panels. It provides individually fused outputs, ensuring protection for connected devices. The board is constructed from durable phenolic or fiberglass material and is UL Recognized, meeting UL294 standards for access control system units.

Altronix ACM8 Access Power Controller board with eight fused outputs

Figura 1: Dall'alto verso il basso view of the Altronix ACM8 Access Power Controller board, showing the eight fused outputs, relays, and terminal blocks.

Altronix ACM8 Access Power Controller board at an angle

Figura 2: Angolato view of the Altronix ACM8 Access Power Controller, highlighting the compact design and component layout.

3 Caratteristiche

  • Eight individually fused outputs for device protection.
  • Ingresso volumetage: 12 to 24 Volt AC or DC.
  • Volume di uscitatage: 12 to 24 Volt AC or DC.
  • UL Recognized and UL294 compliant for access control applications.
  • Constructed from durable Phenolic or Fiberglass material.
  • Dimensioni compatte per una facile integrazione.

4. Specifiche

SpecificazioneDettaglio
Numero di modelloACM8
Dimensioni del prodotto (L x P x A)8 x 4.5 x 1.25 pollici
Ingresso volumetage12 to 24 Volt AC or DC
Volume di uscitatage12 to 24 Volt AC or DC
Numero di uscite8 (Fused)
MaterialePhenolic or Fiberglass
StandardUL RECOGNIZED, UL294
Peso dell'articolo11.2 once
ProduttoreAltronix

5. Impostazione

  1. Montaggio dell'unità: Securely mount the ACM8 board in a suitable enclosure or panel using appropriate hardware. Ensure adequate ventilation if enclosed.
  2. Collegamento elettrico: Connect the main power source (12-24V AC or DC) to the designated input terminals. Observe correct polarity when using a DC input. Refer to the board markings for positive (+) and negative (-) terminals.
  3. Connessioni di uscita: Connect your access control devices (e.g., locks, readers) to the individually fused output terminals. Each output provides power when triggered. Ensure proper wiring for each connected device according to its specifications.
  4. Ingresso trigger: Connect the trigger input from your access control panel or other control device to the ACM8's trigger terminals. This signal will activate the corresponding output.
  5. Messa a terra: Ensure the unit is properly grounded according to local electrical codes and safety standards.

6. Istruzioni per l'uso

  1. Accendere: Once all connections are secure and verified, apply power to the ACM8 unit.
  2. Indicatori LED: Each output has an associated LED indicator. When an output is active and power is flowing correctly through its fuse, the corresponding LED will illuminate.
  3. Funzionalità di attivazione: When a trigger signal is received at the input, the ACM8 will activate the designated output, providing power to the connected access control device.
  4. Fuse Monitoring: The LED indicators also serve as a visual check for fuse integrity. If an LED is off when the output should be active, it indicates a potential blown fuse or a wiring issue to the connected device.

7. Manutenzione

  • Ispezione regolare: Controllare periodicamente tutti i collegamenti elettrici per assicurarsi che siano saldi e privi di corrosione o danni.
  • Sostituzione fusibile: If an output fuse blows, always replace it with a fuse of the same type and rating (e.g., 250V, 2A). Using an incorrect fuse can damage the unit or connected devices.
  • Pulizia: Keep the unit free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
  • Condizioni ambientali: Ensure the operating environment remains within specified temperature and humidity ranges to prevent malfunction.

8. Risoluzione Dei Problemi

  • No Power to Any Outputs:
    • Verify that the main input power supply is active and correctly connected to the ACM8.
    • Check the main fuse (if applicable to your power supply) and ensure it is intact.
  • Individual Output Failure (LED off when active):
    • Check the specific output fuse for the affected channel. Replace if blown.
    • Verify the wiring to the connected device for shorts or disconnections.
    • Ensure the trigger signal for that specific output is being received correctly.
  • Funzionamento intermittente:
    • Inspect all terminal connections for looseness.
    • Controllare il volumetage fluctuations from the input power supply.

9. Garanzia e supporto

For detailed warranty information, technical assistance, or to inquire about service, please contact Altronix customer service directly or visit the official Altronix webluogo. Conserva la ricevuta di acquisto per eventuali richieste di garanzia.

Documenti correlati - ACM8

Preview Guida all'installazione dei kit Altronix Trove2/Mercury con uscite con fusibile
Guida all'installazione per i kit Altronix Trove2/Mercury, che descrive in dettaglio vari modelli di uscite con fusibile, opzioni di configurazione e istruzioni di montaggio per i sistemi di controllo accessi. Include oltreview, tabelle di configurazione, fasi di installazione e dimensioni dell'involucro.
Preview Guida all'installazione del kit di integrazione di accesso e alimentazione Trove Paxton Altronix T2PXK78 e T2PXK78D
Comprehensive installation guide for Altronix Trove Paxton kits (T2PXK78, T2PXK78D). Learn how to set up advanced access control and power integration systems featuring Altronix power supplies, controllers, and Paxton Net2 Plus modules.
Preview Altronix AL175UL Alimentatore/Caricabatterie per Controllo Accessi - Specifiche Tecniche e Guida all'Installazione
Specifiche tecniche dettagliate, istruzioni di installazione e diagrammi applicativi per l'alimentatore/caricabatterie per il controllo degli accessi Altronix AL175UL, progettato per applicazioni di interfaccia antincendio e UL294.
Preview Altronix/Trove3 Mercury Kits Installation Guide
Comprehensive installation guide for Altronix Trove3 Mercury Kits, detailing models T3MK75F16, T3MK75F16D, T3MK77F16, and T3MK77F16D. Covers product overview, configuration chart, hardware, mechanical specifications, step-by-step installation instructions, and LINQ2 network module features.
Preview Guida all'installazione dei controller di accesso a doppia alimentazione Altronix Maximal V Series
This installation guide provides comprehensive instructions for setting up and configuring the Altronix Maximal V Series Dual Power Supply Access Power Controllers. Designed for robust access control systems, these units offer 16 fused, independently controlled outputs with dual power supply capabilities.
Preview Guida all'installazione dei kit Wiegand Altronix/DMP 734/734N
Guida completa all'installazione per i kit Wiegand Altronix/DMP 734/734N, inclusi i modelli T1DMK3F4, T1DMK3F4D, T2DMK7F8 e T2DMK7F8D. Copre oltre il kitviews, elenchi dei componenti, una tabella di configurazione, procedure di installazione passo passo, requisiti hardware, schemi di montaggio dei moduli, dimensioni dell'involucro e informazioni sul modulo di comunicazione di rete LINQ2 opzionale. Essenziale per integratori e tecnici che configurano le soluzioni di alimentazione per il controllo degli accessi Altronix.