1. Introduzione e oltreview
The Altronix 6062 Multi-Function Timer is a versatile programmable timer designed for various applications requiring precise timing control. It operates on either 12VDC or 24VDC and features SPDT (Single Pole Double Throw) contacts rated at 8 amp/115VAC. This unit offers an adjustable timing range from 1 second to 60 minutes, with a unique capability to provide a momentary relay activation at the conclusion of a set timing cycle.
This manual provides essential information for the proper installation, operation, and maintenance of your Altronix 6062 Multi-Function Timer.
2 Caratteristiche
- Multi-function programmable timer.
- Flexible power input: 12VDC or 24VDC operation.
- High-capacity SPDT contacts rated at 8 amp/115VAC.
- Wide adjustable timing range: 1 second to 60 minutes.
- Features momentary relay activation at the end of the timing cycle.
- Design compatto e durevole.
- Prodotto in USA
- A norma RoHS.
3. Configurazione e installazione
Informazioni importanti sulla sicurezza: Installation should be performed by qualified personnel in accordance with all local and national electrical codes. Disconnect all power before installation or servicing.
3.1. Montaggio
Mount the Altronix 6062 timer in a secure, dry location, away from excessive heat or moisture. Ensure adequate ventilation around the unit.
3.2. Cablaggio
The Altronix 6062 timer requires a 12VDC or 24VDC power source. Connect the power supply to the designated input terminals, observing correct polarity. The unit features SPDT contacts for controlling external devices. Wire your load to the Normally Open (NO) or Normally Closed (NC) contacts and the Common (C) terminal as required by your application. Refer to the product's included wiring diagram for specific connection points.

Image of the Altronix 6062 Multi-Function Timer in its blue and white retail box, displaying the model number, key features, and Altronix branding.
4. Istruzioni per l'uso
4.1. Setting the Timing Range
The Altronix 6062 allows for an adjustable timing range from 1 second to 60 minutes. The timing duration is typically set via an onboard potentiometer or dip switches. Carefully adjust the setting to achieve the desired delay for your application. Test the timing repeatedly to ensure accuracy.
4.2. Momentary Relay Activation
This timer includes a feature for momentary relay activation at the completion of the set timing cycle. This can be utilized to trigger a brief event or signal after the primary delay has elapsed. Consult the specific wiring and configuration details provided with your unit for enabling and utilizing this function.
5. Manutenzione
The Altronix 6062 Multi-Function Timer is designed for reliable, maintenance-free operation under normal conditions. To ensure optimal performance and longevity:
- Controllare periodicamente tutti i collegamenti elettrici per assicurarsi che siano saldi e privi di corrosione.
- Keep the unit free from dust, dirt, and debris. Use a soft, dry cloth for cleaning.
- Do not expose the unit to extreme temperatures, humidity, or direct water contact.
- Non tentare di aprire il casing or service internal components. Refer all servicing to qualified personnel.
6. Risoluzione Dei Problemi
If you encounter issues with your Altronix 6062 Multi-Function Timer, consider the following troubleshooting steps:
- No Power/Unit Not Functioning:
- Verify that the correct DC input voltage (12VDC or 24VDC) is applied to the power terminals.
- Check for correct power supply polarity.
- Assicurarsi che tutti i collegamenti elettrici siano saldi.
- Incorrect Timing/Relay Not Activating:
- Re-adjust the timing potentiometer or settings to the desired duration.
- Confirm that the load connected to the SPDT contacts is within the specified 8 amp/115VAC rating.
- Check all load wiring connections for security and continuity.
- Ensure the timing cycle is completing as expected before the relay is supposed to activate.
For persistent issues or problems not covered here, please contact Altronix technical support.
7. Specifiche
| Attributo | Dettaglio |
|---|---|
| Produttore | Società Altronix |
| Numero di parte | 6062 |
| Numero modello articolo | 6062SP |
| Potenza in ingresso | 12 V CC o 24 V CC |
| Tipo di contatto | SPDT (polo singolo doppio lancio) |
| Valutazione del contatto | 8 amp/115 V CA |
| Intervallo di tempo | 1 secondo a 60 minuti |
| Peso dell'articolo | 2.08 once |
| Dimensioni del prodotto | 1 x 1 x 1 pollici |
| Materiale | Fibra di vetro |
| Data prima disponibilità | 25 luglio 2010 |
| Conforme alla direttiva RoHS | SÌ |
8. Garanzia e supporto
Altronix products are engineered for superior performance and reliability. The Altronix 6062 Multi-Function Timer is backed by a Garanzia a vita, garantendo tranquillità a lungo termine.
For technical support, warranty claims, or additional product information, please visit the official Altronix websito o contattare il servizio clienti:
Websito: altronix.com
Quando contatti l'assistenza, tieni a portata di mano il numero di modello del tuo prodotto (6062) e tutte le informazioni rilevanti sull'acquisto.