GewissGW96932

Gewiss GW96932 Relay User Manual

Modello: GW96932

1. Introduzione

This manual provides essential information for the safe and correct installation, operation, and maintenance of the Gewiss GW96932 Relay. This device is a 2-way (DPDT) relay designed for switching electrical circuits with a 24V DC coil and 16A contact rating. Please read these instructions thoroughly before installation and retain them for future reference.

2. Informazioni sulla sicurezza

Electrical installations must be carried out by qualified personnel in accordance with national and local wiring regulations. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect power to the circuit before installing, servicing, or removing the relay.
  • Verificare che il volume di fornituratage and current ratings match the relay's specifications.
  • Non azionare il relè se sembra danneggiato.
  • Assicurarsi che tutti i collegamenti siano sicuri e adeguatamente isolati.
  • This relay is designed for indoor use in dry environments unless otherwise specified.

3. Prodotto finitoview

The Gewiss GW96932 is a compact electromechanical relay. It features a 24V DC coil and two sets of changeover contacts (DPDT - Double Pole Double Throw), each rated for 16A. The relay is typically mounted on a DIN rail or within an enclosure.

Gewiss GW96932 Relay front view mostrando i terminali

Figura 1: Davanti view of the Gewiss GW96932 Relay. This image illustrates the general appearance of the relay, including its housing and visible terminal connections for the coil and contacts. The compact design is suitable for integration into control panels.

The relay's terminals are typically labeled for easy identification of the coil connections and the common (COM), normally open (NO), and normally closed (NC) contacts for each pole.

4. Installazione e configurazione

4.1 Montaggio

The GW96932 relay is designed for secure mounting within an electrical enclosure or on a standard DIN rail, depending on the specific model and base used. Ensure adequate ventilation around the relay to prevent overheating.

4.2 Cablaggio

Refer to the wiring diagram provided with the relay or on its housing for precise terminal connections. The following is a general guide:

  • Collegamenti della bobina: Collegare il controllo 24V DC voltage to the designated coil terminals. Observe polarity if indicated.
  • Collegamenti di contatto: Connect the load circuit to the appropriate contact terminals (Common, Normally Open, Normally Closed). Ensure the load current does not exceed 16A per contact.
  • Use appropriate wire gauges for the current being carried to prevent overheating.

Dopo aver eseguito il cablaggio, verificare nuovamente che tutti i collegamenti siano ben serrati e corretti prima di applicare l'alimentazione.

5. Istruzioni per l'uso

The Gewiss GW96932 relay operates by energizing its 24V DC coil. When the coil is energized, the internal contacts switch from their normally closed (NC) position to their normally open (NO) position. When the coil is de-energized, the contacts return to their original NC position.

  • Apply 24V DC to the coil terminals to activate the relay.
  • Remove 24V DC from the coil terminals to deactivate the relay.
  • The relay acts as a switch, controlling the flow of current through the connected load circuits.

6. Manutenzione

The Gewiss GW96932 relay is generally maintenance-free under normal operating conditions. However, periodic inspection is recommended:

  • Visually inspect the relay for any signs of physical damage, discoloration, or overheating.
  • Check all terminal connections for tightness to ensure good electrical contact.
  • Assicurarsi che l'ambiente operativo rimanga entro i limiti di temperatura e umidità specificati.

Do not attempt to open or repair the relay. If the relay malfunctions, it should be replaced by a qualified technician.

7. Risoluzione Dei Problemi

Se il relè non funziona come previsto, considerare quanto segue:

  • Relè non attivato:
    • Check if 24V DC is present at the coil terminals when activation is expected.
    • Verify coil polarity if applicable.
    • Ensure the coil terminals are securely connected.
  • Il carico non commuta:
    • Confirm the relay coil is activating (a click sound or visual indicator if present).
    • Check continuity across the contacts when the relay is activated.
    • Ensure the load circuit is correctly wired to the NO or NC contacts as intended.
    • Verify the load current does not exceed the contact rating (16A).
  • Surriscaldamento:
    • Ensure adequate ventilation around the relay.
    • Check if the load current exceeds the relay's contact rating.

If issues persist, consult a qualified electrician or contact Gewiss support.

8. Specifiche

ParametroValore
Numero di modelloGW96932
MarcaGewiss
Bobina voltage24V CC
Configurazione dei contatti2W (DPDT - Double Pole Double Throw)
Contatta la valutazione attuale16A
Volume di eserciziotage (Contatti)Up to 250 Volts (AC/DC, depending on load type)
ColoreWhite (Farbe Weiß)
Quantità1

9. Smaltimento

This product should not be disposed of with household waste. Please dispose of it in accordance with local regulations for electronic waste. Proper disposal helps prevent potential negative consequences for the environment and human health.

10. Garanzia e supporto

Gewiss products are manufactured to high-quality standards. For information regarding warranty terms, technical support, or spare parts availability, please refer to the official Gewiss website or contact your local Gewiss distributor. Keep your purchase receipt as proof of purchase.

Documenti correlati - GW96932

Preview GEWISS CHORUSMART CVD 4X10A DIN Rail LED Dimmer Booster - Specifiche Tecniche
Specifiche tecniche dettagliate e guida all'installazione del booster per guida DIN GEWISS CHORUSMART CVD 4X10A, progettato per estendere la capacità di controllo dei dimmer LED.
Preview GEWISS JOINON GWJ8037 & GWJ8038 Interfaccia di rete RJ45 Guida all'installazione
Installazione e sistema finitoview per moduli di interfaccia di rete RJ45 CAT. 5 F/UTP GEWISS JOINON GWJ8037 (1PH) e GWJ8038 (3PH), inclusi schemi elettrici e integrazione del sistema con l'energia solare.
Preview Modulo di comando assiale ausiliario GEWISS Chorusmart GW10677/GW10678: Guida all'installazione e alla tecnica
Guida completa per i moduli di comando assiale ausiliario GEWISS Chorusmart GW10677 e GW10678. Copre sicurezza, informazioni generali, funzioni LED, collegamento examples, assemblaggio, manutenzione e specifiche tecniche per la domotica intelligente.
Preview Modulo dimmer assiale connesso Gewiss CHORUSMART - Guida all'installazione e alla tecnica
Guida completa per il modulo dimmer assiale connesso Gewiss CHORUSMART (GWA1221, GWA1222), che copre installazione, funzioni, specifiche tecniche, connettività Zigbee e informazioni sulla sicurezza.
Preview Apparecchio di illuminazione a LED GEWISS SMART [3] - Guida all'installazione e avvertenze
Guida all'installazione e avvertenze di sicurezza per l'apparecchio di illuminazione a LED GEWISS SMART [3]. Scopri i gradi di protezione IP66/IP69, le precauzioni per l'installazione in esterni e la sicurezza elettrica.
Preview Booster GEWISS CHORUSMART per dimmer LED CVD 4x16A - Montaggio su guida DIN
Specifiche tecniche e guida all'installazione del Booster GEWISS CHORUSMART, modello GW90768, progettato per estendere la capacità di controllo dei dimmer LED CVD fino a 16 A per canale. Adatto al montaggio su guida DIN e ai sistemi KNX.