YASKAWA CIMR-VU4A0011FAA

YASKAWA V1000 Series AC Drive User Manual

Model: CIMR-VU4A0011FAA

Introduzione

This manual provides essential information for the safe and effective use of the YASKAWA V1000 Series AC Drive, model CIMR-VU4A0011FAA. The V1000 is a compact, high-performance variable frequency drive designed for a wide range of industrial applications, offering precise motor control and energy efficiency. Please read this manual thoroughly before installation, operation, or maintenance.

Yaskawa V1000 AC Drive, main view

Figure 1: Yaskawa V1000 AC Drive, showing the main unit with its grey casing and heat sink fins.

Informazioni sulla sicurezza

Always observe the following safety precautions to prevent injury, damage to equipment, or property loss. This drive contains high voltage components and should only be handled by qualified personnel.

Impostare

1. Disimballaggio e ispezione

Carefully remove the drive from its packaging. Inspect the unit for any signs of damage that may have occurred during shipping. Verify that all components listed in the packing list are present.

Yaskawa V1000 AC Drive with instruction manual

Figure 2: The Yaskawa V1000 AC Drive unit shown alongside its accompanying instruction manual, still in its plastic packaging.

2. Montaggio

Mount the drive vertically on a flat, stable surface. Ensure adequate clearance for ventilation around the unit. Refer to the dimensions provided in the specifications section for proper spacing. Avoid mounting in direct sunlight or near heat sources.

3. Cablaggio

All wiring must comply with national and local electrical codes. Use appropriate wire gauges for power, motor, and control circuits. Ensure proper grounding of the drive chassis and motor frame.

Metter il fondo a view of Yaskawa V1000 AC Drive

Figura 3: parte inferiore view of the Yaskawa V1000 AC Drive, showing the heat sink fins and mounting points, crucial for proper ventilation and installation.

4. Accensione iniziale

Before applying power, double-check all wiring connections. Ensure no loose wires or foreign objects are present. Apply power and observe the drive's display. The drive should power on and display its default status or a ready message.

Operativo

1. Funzionamento di base

The V1000 drive can be operated via its built-in keypad, external control terminals, or serial communication. For basic operation using the keypad:

  1. Premere il tasto CORRERE pulsante per avviare il motore.
  2. Premere il tasto FERMARE pulsante per arrestare il motore.
  3. Utilizzare il SU/GIÙ arrow keys to adjust the output frequency (motor speed) if in frequency reference mode.

2. Impostazioni dei parametri

The drive's behavior is configured through various parameters. Access the parameter menu via the keypad. Key parameters include:

Refer to the comprehensive parameter list in the full YASKAWA V1000 technical manual for detailed descriptions and settings.

Manutenzione

Regular maintenance ensures optimal performance and extends the lifespan of your V1000 AC Drive. Always disconnect power before performing any maintenance.

Risoluzione dei problemi

This section provides guidance for common issues. For detailed fault codes and advanced troubleshooting, consult the full YASKAWA V1000 technical manual.

SintomoPossibile causaAzione correttiva
L'unità non si accendeNessuna alimentazione in ingresso; fusibile bruciato; guasto internoCheck power supply; Inspect fuses; Contact support if internal fault suspected.
Il motore non funzionaIncorrect wiring; Parameter settings; External stop signal activeVerify wiring (motor/control); Check parameter settings (e.g., frequency reference, run command source); Ensure no active stop signals.
Guasto da sovracorrente (OC)Sovraccarico del motore; Cortocircuito nel motore/cavi; Rapida accelerazione/decelerazioneCheck motor load; Inspect motor and cables for damage; Increase acceleration/deceleration times.
Sovravoltagguasto e (OV)Energia rigenerativa dal motore; Alto volume di ingressotageIncrease deceleration time; Install braking resistor if necessary; Verify input voltage.

Specifiche

Key technical specifications for the YASKAWA V1000 AC Drive, model CIMR-VU4A0011FAA:

ParametroValore
Numero di modelloCIMR-VU4A0011FAA
Ingresso volumetageAC 3-Phase 380-480V
Frequenza di ingressoFrequenza 50/60 Hz
Input Current (Rated)14.0A (380V) / 10.4A (480V)
Volume di uscitatageAC 3-Phase 0-480V
Frequenza di uscitaFrequenza
Corrente di uscita (nominale)11.1A (380V) / 9.2A (480V)
Mass / Weight2.6 kg (circa 5.73 libbre)
Valutazione dell'involucroGrado di protezione IP20
ProduttoreYASKAWA
Paese di origineGiappone
ASINB008HQ5TP0
Product label of Yaskawa V1000 AC Drive showing model and electrical specifications

Figure 4: Detailed product label of the Yaskawa V1000 AC Drive, displaying the model number, input/output electrical ratings, and manufacturing information.

Garanzia e supporto

YASKAWA products are manufactured to high standards and typically come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty documentation included with your purchase or visit the official YASKAWA websito.

For technical support, service, or to inquire about replacement parts, please contact YASKAWA customer service or an authorized YASKAWA distributor. Provide your product model number (CIMR-VU4A0011FAA) and serial number when seeking assistance.

You can find more information and contact details on the official YASKAWA websito: www.yaskawa.com

Documenti correlati - CIMR-VU4A0011FAA

Preview YASKAWA AC Drive L1000A: Guida rapida per applicazioni di ascensori
Questa Guida Rapida all'Installazione del Convertitore di Frequenza Yaskawa L1000A fornisce informazioni essenziali per l'installazione, il cablaggio e la configurazione iniziale sicuri ed efficaci dei convertitori di frequenza per applicazioni in ascensori. Illustra le precauzioni di sicurezza fondamentali, l'installazione meccanica ed elettrica, l'utilizzo della tastiera e le procedure di avviamento.
Preview YASKAWA AC Drive A1000 Quick Start Guide
Quick Start Guide for the YASKAWA AC Drive A1000 series, a high-performance vector control drive. This manual provides essential information for safe installation, wiring, initial setup, operation, and troubleshooting of industrial AC drives.
Preview Manuale di comunicazione Modbus per azionamenti Yaskawa V7 e V74X
Guida alla comunicazione Modbus per gli azionamenti CA Yaskawa V7 e V74X, che copre la configurazione di rete (RS-232, RS-422, RS-485), l'accesso ai parametri, i formati dei messaggi e la risoluzione dei problemi per l'automazione industriale.
Preview Yaskawa AC Drive - Supplemento software personalizzato ad alta frequenza A1000
Questo documento integra la Guida rapida e il Manuale tecnico Yaskawa A1000, descrivendo in dettaglio le modifiche e le nuove funzioni del software personalizzato ad alta frequenza. ...
Preview Manuale utente dell'azionamento CA Yaskawa Z1000 per applicazioni di pompe e ventilatori HVAC
Questo manuale utente completo fornisce istruzioni dettagliate per l'inverter Yaskawa Z1000 AC, coprendo l'installazione, la configurazione, la programmazione, il funzionamento e la risoluzione dei problemi per applicazioni HVAC con ventilatori e pompe. Include specifiche per le classi 200 V e 400 V.
Preview Yaskawa V1000 to GA500 AC Drive Transition Guide
A comprehensive guide for OEMs, integrators, and end-users transitioning from Yaskawa V1000 series AC drives to the Yaskawa GA500 AC drives. This document covers model identification, drive selection, dimensions, wiring, and branch circuit protection.