1. Introduzione
This manual provides essential instructions for the safe and effective operation of the Hioki 3030-10 HiTester Analog Multimeter. This device is an average-sensing, manual-ranging meter designed for measuring voltage, resistance, and current in various electrical testing applications. Please read this manual thoroughly before use and retain it for future reference.
2. Informazioni sulla sicurezza
To ensure safe operation and prevent damage to the device, observe the following safety precautions:
- The meter is designed to meet International Electrotechnical Commission (IEC) safety standard 61010.
- It is certified for Category III installations up to 600V, suitable for use with enclosed building circuit installations (e.g., service panel parts, branch circuits, fixed installations connected directly to AC power supply).
- Un 0.5-amp/250V fuse is installed to protect the operator from electric shock due to transient voltage. Do not bypass or use an incorrect fuse.
- Always select the appropriate measurement range before connecting the test leads to the circuit.
- Non superare i valori massimi di ingresso per nessuna funzione.
- Controllare i puntali per verificare che non siano danneggiati prima di ogni utilizzo. Sostituirli se l'isolamento è compromesso.
- The meter is designed to withstand falls of up to 1 meter onto hardwood or concrete. However, avoid dropping the device.
3. Contenuto della confezione
Verificare che tutti gli elementi siano presenti:
- Hioki 3030-10 HiTester Analog Multimeter
- Detachable Test Leads (Red and Black)
- Custodia per il trasporto
- Manuale dell'utente (questo documento)
4. Prodotto finitoview e Caratteristiche

Figura 1: Hioki 3030-10 HiTester Analog Multimeter. The image displays the multimeter unit, its protective carrying case, and the red and black test leads. The multimeter features a clear analog display with multiple scales for various measurements, a central rotary switch for function and range selection, and input jacks for the test leads.
The Hioki 3030-10 is an analog multimeter designed for reliable electrical measurements. Key features include:
- Display analogico: Provides a clear, real-time indication of measurements, useful for observing trends and fluctuations.
- Misurazione manuale della distanza: Requires the user to select the appropriate measurement range for precision.
- Average-Sensing: Delivers accurate readings for linear loads with undistorted waveforms.
- Funzioni di misurazione: Misura DC/AC voltage, corrente continua e resistenza.
- Battery Test Feature: Determines charge level for 1.5V batteries.
- LED Test Function: Allows testing of LED lights.
- Temperature Measurement Capability: Requires a separately sold thermistor probe.
- Conformità alla sicurezza: Meets IEC 61010, CAT III 600V safety standards.
- Design durevole: Engineered to withstand drops up to 1 meter.
5. Impostazione
5.1 Installazione della batteria
The Hioki 3030-10 requires two AAA batteries for operation. To install or replace batteries:
- Ensure the multimeter is turned OFF (rotary switch set to 'OFF').
- Individuare il coperchio del vano batterie sul retro dell'unità.
- Open the cover and insert two AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Chiudere saldamente il coperchio del vano batterie.
5.2 Collegamento del puntale di prova
Connect the detachable test leads to the multimeter:
- Inserire il puntale di prova nero nel jack di ingresso "COM" (comune).
- Insert the red test lead into the "VΩmA" input jack for voltagmisurazioni di e, resistenza e corrente.
- Prima di procedere con qualsiasi misurazione, assicurarsi che i collegamenti siano saldi.
6. Istruzioni per l'uso
The Hioki 3030-10 is a manual-ranging multimeter. Always select the appropriate function and range using the rotary switch before making a measurement.
6.1 Volume CCtage Misurazione (V)
- Impostare il selettore rotativo sul volume CC desideratotage (V) range (e.g., 0.3V, 3V, 12V, 30V, 120V, 300V, 600V). Start with the highest range if the voltage è sconosciuto.
- Collegare il puntale di prova rosso al lato positivo (+) del circuito e il puntale di prova nero al lato negativo (-).
- Leggi il vol.tage value from the appropriate DCV scale on the analog display.
6.2 Volume ACtage Measurement (~V)
- Impostare il selettore rotativo sul volume CA desideratotage (~V) range (e.g., 12V, 30V, 120V, 300V, 600V). Start with the highest range if the voltage è sconosciuto.
- Collegare i puntali di prova attraverso la tensione CAtage fonte.
- Leggi il vol.tage value from the appropriate ACV scale on the analog display.
6.3 Misurazione della corrente continua (A)
Attenzione: Collegare sempre il multimetro in serie al circuito quando si misura la corrente. Non collegarlo mai in parallelo a un voltmetro.tage fonte.
- Set the rotary switch to the desired DC Current (A) range (e.g., 60µA, 30mA, 300mA). Start with the highest range if the current is unknown.
- Break the circuit and connect the multimeter in series, ensuring the current flows through the meter.
- Read the current value from the appropriate DCA scale on the analog display.
6.4 Misurazione della resistenza (Ω)
Attenzione: Prima di misurare la resistenza, assicurarsi che il circuito sia disattivato.
- Set the rotary switch to the desired Resistance (Ω) range (e.g., x1, x10, x100, x1k).
- Before measuring, short the test leads together and adjust the "Ω ADJ" knob (if present) to zero the meter.
- Collegare i puntali di prova al componente da misurare.
- Read the resistance value from the Ω scale on the analog display and multiply by the selected range multiplier.
6.5 Battery Test (BATT 1.5V)
- Set the rotary switch to the "BATT 1.5V" position.
- Connect the red test lead to the positive (+) terminal of the 1.5V battery and the black test lead to the negative (-) terminal.
- Read the battery charge level from the "BATT" scale on the analog display.
6.6 LED Test (LED)
- Set the rotary switch to the "LED" position.
- Connect the test leads to the LED. Observe polarity; if the LED does not light, reverse the leads.
- A lit LED indicates functionality.
6.7 Misurazione della temperatura (TEMP)
This function requires a separately purchased thermistor probe. Refer to the thermistor probe's manual for specific connection and operation instructions.
- Impostare l'interruttore rotante sulla posizione "TEMP".
- Connect the thermistor probe to the designated input jacks.
- Read the temperature from the "TEMP(°C)" scale on the analog display.
7. Manutenzione
7.1 Pulizia
Pulisci il contatore casing con un morbido, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is off and disconnected from all circuits before cleaning.
7.2 Sostituzione del fusibile
If the current measurement function ceases to operate, the fuse may need replacement. The Hioki 3030-10 uses a 0.5-amp/250V fuse. Always replace with a fuse of the identical type and rating.
- Assicurarsi che il multimetro sia spento e che i puntali di prova siano scollegati.
- Refer to the device's internal diagram (if available) or contact customer support for instructions on accessing the fuse compartment.
- Carefully remove the old fuse and insert the new 0.5A/250V fuse.
- Reassemble the meter securely.
7.3 Conservazione
When not in use, store the multimeter in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if storing for extended periods to prevent leakage.
8. Risoluzione Dei Problemi
If the multimeter does not function as expected, consider the following:
- Nessun display/alimentazione: Controllare l'installazione delle batterie e assicurarsi che non siano scariche. Sostituirle se necessario.
- Letture errate:
- Assicurarsi che siano selezionati la funzione e l'intervallo corretti per la misurazione.
- Verificare che i puntali di prova siano collegati correttamente e non danneggiati.
- For resistance measurements, ensure the circuit is de-energized and the meter is zeroed.
- Current Function Not Working: Check the internal fuse (refer to Section 7.2).
- L'ago non si muove: Ensure the meter is powered on and the test leads are making good contact with the circuit. Check for open circuits.
If problems persist after attempting these steps, contact Hioki customer support for further assistance.
9. Specifiche
| Parametro | Valore |
|---|---|
| Numero di modello | 3030-10 |
| Tipo di misurazione | Analog Multimeter (Average-Sensing, Manual-Ranging) |
| Volume DCtage Intervalli | 0.3V, 3V, 12V, 30V, 120V, 300V, 600V |
| Volume ACtage Intervalli | 12 V, 30 V, 120 V, 300 V, 600 V |
| DC Current Ranges | 60µA, 30mA, 300mA |
| Intervalli di resistenza | x1, x10, x100, x1k (Max 3MΩ) |
| Test della batteria | Batterie da 1.5V |
| Protezione Fusibile | 0.5A / 250V |
| Standard di sicurezza | IEC 61010, CAT III 600 V |
| Fonte di alimentazione | 2 batterie AAA (non incluse) |
| Peso dell'articolo | 150 grammi |
| Dimensioni del prodotto (L x P x A) | Dimensioni: 15.75 x 15.49 x 5.84 cm |
| Volume di eserciziotage (Min.) | 0.3 Volt (CC) |
| Valutazione della temperatura superiore | 150 gradi Celsius |