1. Introduzione
The APC Back-UPS RS 700 VA Tower UPS (Uninterruptible Power Supply) provides reliable battery backup and surge protection for your electronic devices. Designed to safeguard your equipment from power outages, surges, and spikes, this unit ensures continuous operation and protects against data loss. It features a 700VA/450W capacity, offering approximately 3 minutes of full load runtime.

Figura 1: Davanti view of the APC Back-UPS RS 700 VA Tower UPS. The display shows current load, online status, estimated run time in minutes (e.g., 30 minutes), and AVR (Automatic Voltage Regulation) status. Power and display control buttons are located at the top.
Caratteristiche principali:
- Modalità verde: Patented operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Battery Failure Notification: Fornisce un'analisi tempestiva dei guasti sulle batterie consentendo una tempestiva manutenzione preventiva.
- Power-Saving Outlets: Automatically cuts power to idle equipment to conserve electricity.
- Interruttore automatico ripristinabile: Facile recupero dai sovraccarichi; non c'è bisogno di sostituire un fusibile.
- Prese protette da batteria e solo contro le sovratensioni: Protects connected equipment from power surges and spikes, while providing battery backup power during outages to critical devices.
- Cold-Start Capable: Fornisce alimentazione temporanea alla batteria quando l'alimentazione di rete è interrotta.
- Batterie sostituibili a caldo: Garantisce un'alimentazione pulita e ininterrotta alle apparecchiature protette durante la sostituzione delle batterie.
- Notifica di batteria scollegata: Avvisa quando una batteria non è disponibile per fornire alimentazione di backup.
- Protezione contro le sovratensioni della linea dati: Provides protection of connected equipment from power surges on the data lines.
- Autotest automatico: L'autotest periodico della batteria garantisce il rilevamento tempestivo di una batteria che deve essere sostituita.
- Vol. regolabiletage-Transfer Points: Massimizza la durata utile della batteria ampliando il volume di ingressotage window or tightening it to regulate output voltage.
- Vol. regolabiletage Sensibilità: Offre la possibilità di adattare l'UPS per prestazioni ottimali in ambienti di alimentazione specifici o applicazioni con generatori.
- Allarmi sonori: Provides notification of changing utility power and UPS power conditions.
- User-Replaceable Batteries: Increases availability by allowing a trained user to perform upgrades and replacements of batteries reducing Mean Time to Repair (MTTR).
- Connettività USB: Provides management of the UPS via a USB port.
- Connettività seriale: Fornisce la gestione dell'UPS tramite una porta seriale.
- Transformer-Block Spaced Outlets: Protects equipment with input transformer blocks without blocking access to other receptacles.
- Aumenta e regola il volume automaticotage Regolamento (AVR): Corrects low and high voltages without using the battery, extending battery life.
- Gestione intelligente della batteria: Massimizza le prestazioni, la durata e l'affidabilità della batteria attraverso una ricarica intelligente e precisa.
- Safety-Agency Approved: Garantisce che il prodotto sia stato testato e approvato per funzionare in sicurezza con l'apparecchiatura del fornitore di servizi collegato e all'interno dell'ambiente specificato.
- Indicatore di guasto del cablaggio dell'edificio: This LED informs users of potentially dangerous wiring problems in the wall circuit.
- Battery Replacement Without Tools: Enables quick, easy battery replacement.
- LCD Graphics Display: Provides clear, concise information with text and mimic diagrams that display modes of operation, system parameters, and alarms.
2. Impostazione
2.1 Disimballaggio e posizionamento
Carefully unpack the UPS and inspect it for any shipping damage. Place the UPS in a location that is clean, dry, and away from direct sunlight or excessive heat. Ensure adequate ventilation around the unit. The tower form factor allows for vertical placement.
2.2 Collegamento all'alimentazione
- Connect the UPS power cord to a grounded 3-prong outlet. The power cord is approximately 5 feet long, providing flexibility for placement.
- Lasciare caricare l'UPS per almeno 24 ore prima di collegare apparecchiature critiche per garantire la piena capacità della batteria.
- Observe the Building Wiring Fault Indicator. If this LED illuminates, it indicates a potential wiring problem in the wall circuit that should be addressed by a qualified electrician.
2.3 Apparecchiatura di collegamento
The UPS features both battery-protected and surge-only outlets.
- Battery-Protected Outlets (NEMA 5-15R): Connect critical equipment such as computers, monitors, and network devices (modems, routers) to these outlets. These outlets provide power during outage protezione contro le sovratensioni.
- Surge-Only Outlets (NEMA 5-15R): Connect non-critical equipment like printers, scanners, or desk lamps to these outlets. These outlets provide surge protection but do not offer battery backup during a power failure.
2.4 Data Line Protection
Connect your telephone, network, or coaxial cables through the designated ports on the UPS to protect against surges traveling through these lines.
2.5 USB and Serial Connectivity
For advanced management and monitoring, connect the UPS to your computer using the provided USB or serial cable. Install the appropriate power management software (available from APC's website) to configure settings, monitor power conditions, and perform graceful shutdowns.
2.6 Montaggio a parete
The unit can be wall-mounted using the keyhole slots on the back. Ensure the mounting surface is sturdy enough to support the weight of the UPS and that proper fasteners are used.
3. Funzionamento
3.1 Accensione/Spegnimento
- To power on the UPS, press the power button located on the front panel.
- To power off the UPS, press and hold the power button until the unit shuts down.
3.2 LCD Graphics Display
The LCD display provides real-time information about the UPS status, including:
- Livello di carico: Indica la percentualetage della capacità dell'UPS utilizzata dalle apparecchiature collegate.
- Stato online: Shows when the UPS is operating on utility power.
- Tempo di esecuzione stimato: Displays the approximate remaining battery runtime in minutes during a power outage.
- AVR Status: Indicates when Automatic Voltage Regulation is actively correcting input voltage senza utilizzare la batteria.
- Parametri di sistema: Provides details on input/output voltage, frequency, and battery charge level.
- Allarmi: Notifies of critical events or warnings.
3.3 Volume automaticotage Regolamento (AVR)
The Boost and Trim AVR feature automatically corrects minor voltage fluctuations (sags and surges) in incoming utility power without switching to battery power. This preserves battery life and ensures a stable power supply to your connected devices.
3.4 Potenza in uscitatage Risposta
Durante un'interruzione di correntetage, the UPS automatically switches to battery power, providing uninterrupted power to devices connected to the battery-protected outlets. Audible alarms will sound to notify you of the power event. The estimated run time will be displayed on the LCD.
3.5 Green Mode and Power-Saving Outlets
The Green Mode optimizes efficiency by bypassing internal components when utility power is stable. Power-saving outlets can be configured to automatically turn off connected devices when the master device (e.g., your computer) is turned off or goes into standby, reducing energy consumption.
4. Manutenzione
4.1 Cura e sostituzione della batteria
The UPS features user-replaceable and hot-swappable batteries, allowing for replacement without powering down connected equipment.
- Autotest automatico: The UPS performs periodic self-tests to assess battery health.
- Battery Failure Notification: The UPS will provide an early warning if the battery needs replacement.
- Notifica di batteria scollegata: An alarm will sound if the battery is not properly connected.
- Procedura di sostituzione: Batteries can be replaced without tools. Refer to the specific battery replacement instructions provided with your replacement battery or on the APC support website. Always use genuine APC replacement batteries.
4.2 Interruttore automatico ripristinabile
In case of an overload, the UPS's resettable circuit breaker may trip. Disconnect non-essential equipment, then press the circuit breaker button to reset it.
4.3 Pulizia
Keep the UPS clean and free of dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners or solvents. Ensure ventilation openings are not obstructed.
5. Risoluzione Dei Problemi
This section provides solutions to common issues you might encounter with your APC Back-UPS RS 700 VA.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| L'UPS non si accende. | Not connected to utility power; battery not charged; internal fault. | Ensure power cord is securely plugged into a live outlet. Allow 24 hours for initial battery charge. If still unresponsive, contact support. |
| L'allarme acustico suona frequentemente. | Overload; battery low/faulty; utility power issues. | Reduce connected load. Check LCD for specific alarm codes. Ensure proper ventilation. Perform a self-test. |
| Building Wiring Fault Indicator is lit. | Problema di cablaggio nella presa a muro (ad esempio, messa a terra mancante, polarità invertita). | Do not use the outlet. Consult a qualified electrician to inspect and correct the wiring. |
| Durata breve della batteria. | Battery not fully charged; battery nearing end of life; excessive load. | Ensure battery is fully charged. Reduce connected load. Consider replacing the battery if it's old or fails self-test. |
| UPS not providing power during outage. | Devices connected to surge-only outlets; battery disconnected or faulty. | Verify critical devices are connected to battery-protected outlets. Check for disconnected battery notification. Replace battery if faulty. |
6. Specifiche
- Modello: BR700G
- Capacità: Potenza: 700 VA / 450 W
- Ingresso volumetage: 120V AC (Nominal)
- Volume di uscitatage: 120V AC (Nominal)
- Connessioni di uscita: 3 x NEMA 5-15R (Battery Backup & Surge Protection), 3 x NEMA 5-15R (Surge Protection Only)
- Fattore di forma: Torre
- Peso: Circa 0.01 once (Note: This weight is as per provided data. Actual weight for a UPS of this capacity is typically much higher.)
- Ampera: 3 Amps
- Colore: Verde (Note: The product image shows a black/dark grey unit, but specifications list 'Green'.)
- Data prima disponibilità: 12 settembre 2012
- Produttore: APC
7. Garanzia
The APC Back-UPS RS 700 VA Tower UPS (Model BR700G) comes with a Garanzia del produttore di 1 anno. This warranty covers defects in materials and workmanship under normal use. For specific terms, conditions, and to initiate a warranty claim, please refer to the official APC warranty documentation or contact APC customer support.
8. Supporto
For technical assistance, product information, or to purchase replacement parts and accessories, please contact APC customer support or visit their official websito.
- Funzionario APC Websito: www.apc.com
- Assistenza clienti: Fare riferimento all'APC websito per informazioni di contatto regionali.