Danfoss013G0003

Danfoss RA-FN 15 Thermostatic Valve Instruction Manual

Modello: 013G0003

1. Introduzione

This manual provides instructions for the installation, operation, and maintenance of the Danfoss RA-FN 15 Thermostatic Valve, model 013G0003. This valve is designed for use with radiators, featuring an angle connection without pre-setting, and includes a 1/2 inch iron connection and tailpiece. Please read these instructions carefully before installation and use to ensure proper function and safety.

2. Informazioni sulla sicurezza

Always observe general safety precautions when working with heating systems. Improper installation or maintenance can lead to property damage or personal injury.

3. Configurazione e installazione

3.1 Strumenti necessari

3.2 Preparazione

  1. Turn off the heating system and allow it to cool down completely.
  2. Close the isolation valves for the radiator where the thermostatic valve will be installed. If no isolation valves are present, the entire heating system may need to be drained.
  3. Drain any remaining water from the radiator by opening the bleed valve and loosening the existing valve connection.

3.3 Passaggi di installazione

The Danfoss RA-FN 15 valve is designed for an angle connection to the radiator. It includes a 1/2 inch iron connection and a tailpiece.

  1. Remove the old valve from the radiator connection. Clean the threads thoroughly.
  2. Apply thread sealant to the threads of the new Danfoss RA-FN 15 valve and the tailpiece.
  3. Screw the tailpiece into the radiator inlet. Tighten firmly with a wrench, but do not overtighten.
  4. Connect the main valve body to the tailpiece. Ensure the flow direction arrow on the valve body (if present) matches the direction of water flow into the radiator.
  5. Connect the other end of the valve to the heating pipework. Tighten all connections securely to prevent leaks.
  6. Once the valve is installed, slowly open the isolation valves (if closed) and then the bleed valve on the radiator to allow water to refill the system and release trapped air. Close the bleed valve once water flows steadily.
  7. Controllare che tutti i collegamenti non presentino perdite.
Danfoss RA-FN 15 Thermostatic Valve

Image showing the Danfoss RA-FN 15 thermostatic valve, including the valve body and tailpiece. This valve is designed for an angle connection.

4. Istruzioni per l'uso

The Danfoss RA-FN 15 is a thermostatic radiator valve designed to regulate the room temperature by controlling the flow of hot water through the radiator. This model does not feature pre-setting, meaning the maximum flow is determined by the system pressure and the valve's design.

4.1 Regolazione della temperatura

5. Manutenzione

Regular maintenance ensures the longevity and efficient operation of your thermostatic valve.

6. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il radiatore rimane freddoValve pin stuck; air in radiator; thermostatic head set too low; system pressure too low.Remove thermostatic head and gently press pin; bleed radiator; increase temperature setting; check system pressure.
Radiator is too hotThermostatic head set too high; valve not closing completely.Decrease temperature setting; check valve pin for debris or damage.
Perdite d'acqua dai collegamentiCollegamento allentato; sigillante per filettature insufficiente; filettature danneggiate.Tighten connections; reapply thread sealant; replace valve if threads are damaged.

If troubleshooting steps do not resolve the issue, contact a qualified heating technician.

7. Specifiche tecniche

CaratteristicaValore
Numero di modelloNumero di serie: 013G0003
Dimensione della connessione1/2 pollici (1.27 cm)
Tipo di connessioneFemale iron pipe (inlet/outlet)
KV Range0.22 - 0.7 m³/h
kVS Value0.9 m³/ora
Pressione massima di esercizio10 barre
Pressione differenziale massima0.6 barre
Temperatura massima dell'acqua120 °C
MaterialeFerro
Dimensioni del prodotto (L x P x A)Dimensioni: 9.7 x 5.3 x 2.7 cm
Peso240 grammi
Numero di porte2
CertificazioneEU RoHS (6c)

8. Garanzia e supporto

I prodotti Danfoss sono realizzati secondo elevati standard qualitativi. Per informazioni specifiche sulla garanzia, consultare la documentazione fornita con l'acquisto o visitare il sito ufficiale Danfoss. websito. Conservare la prova d'acquisto per eventuali reclami in garanzia.

For technical support, spare parts, or further assistance, please contact your local Danfoss distributor or customer service. Contact information can typically be found on the Danfoss official websito o sulla confezione del prodotto.