Leviton IPS02-1LW

Manuale di istruzioni dell'interruttore a parete con sensore di movimento Leviton Decora IPS02-1LW

Model: IPS02-1LW | Brand: Leviton

Introduzione

This manual provides detailed instructions for the installation, setup, and operation of your Leviton Decora Motion Sensor In-Wall Switch (Model IPS02-1LW). This device is designed to automatically turn lights ON when motion is detected and OFF when the room is vacated, offering convenience and energy savings. Please read all instructions carefully before beginning installation.

Informazioni importanti sulla sicurezza

WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF THE POWER AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING.

  • L'installazione richiede circa 15 minuti.
  • The wiring device shown in this video may be different from the one you are installing.
  • This device may be used with copper or copper-clad wire only.
  • For use with #12 AWG through #14 AWG wire.
  • If you are unsure about any part of the instructions or are uncomfortable, contact a qualified electrician.

Strumenti necessari

Ensure you have the following tools on hand before beginning installation:

  • Cacciavite a testa piatta
  • Cacciavite con testa Phillips
  • Mini cacciavite a testa piatta
  • Electrician's Pliers
  • Spellafili
  • Nastro elettrico
  • Handheld VoltageTester

Istruzioni per l'installazione

1. Prepararsi per l'installazione

  1. Spegni l'alimentazione: Locate the circuit breaker or fuse that controls the power to the switch you are replacing. Turn it OFF.
  2. Verificare che l'alimentazione sia disattivata: Use a handheld voltage tester to confirm that the power is completely off at the switch box. Test all wires.
  3. Identify Hot Wire: Turn the circuit breaker back ON briefly. Carefully use the voltage tester to identify the hot wire (the tester will indicate voltage). Once identified, immediately turn the circuit breaker OFF again and re-test to ensure power is off. Label the hot wire with a small piece of electrical tape for easy identification.
  4. Identify Load and Ground Wires: In a typical wall box for this device, you will find one black wire (hot), a bare copper wire (ground), and another black wire (load). The color of wires can vary; if unsure, consult an electrician.
  5. Preparare i cavi: Ensure wires are straight and stripped according to the strip gauge located on the back of the device.

2. Wiring the Motion Sensor Switch

The IPS02-1LW switch offers the option of either wrapping leads around the terminal screws or using an external back-wire clamp. This guide demonstrates back-wiring.

  • Collegare il filo di carico: Connect the load wall box wire to the terminal screw marked "RD" (Red).
  • Collegare il filo caldo: Connect the line hot wall box wire to the terminal screw marked "BK" (Black).
  • Collegare il filo di terra: Connect the green or bare copper wire in the wall box to the green terminal screw on the device.
  • Filo neutro: Neutral wires are NOT required for this installation and should be capped off and placed back into the wall box if present.

3. Montaggio del dispositivo

  1. Posizionare tutti i cavi in ​​modo da lasciare spazio nella scatola a muro per il dispositivo.
  2. Ensure the word "TOP" is facing up on the device.
  3. Partially screw in the mounting screws into the wall box mounting holes.

4. Guida video all'installazione

This video demonstrates the installation process for Leviton IPS02, IPS05, IPS06 Occupancy Sensors and IPV02, IPV05 Vacancy Sensors, including wiring and initial setup steps. It covers identifying wires, making connections, and mounting the device.

5. Immagini del prodotto

Leviton Decora Motion Sensor In-Wall Switch IPS02-1LW
Davanti view of the Leviton Decora Motion Sensor In-Wall Switch (IPS02-1LW) in white, showing the sensor lens and manual override button.
Leviton Decora Motion Sensor In-Wall Switch IPS02-1LW Dimensions
Technical drawing showing the dimensions of the Leviton Decora Motion Sensor In-Wall Switch (IPS02-1LW) in inches and millimeters.

Istruzioni per l'uso

1. Initial Power-Up and Testing

  1. Ripristinare l'alimentazione dall'interruttore automatico o dal fusibile.
  2. For IPS02 (Occupancy Sensor): Lights will automatically turn ON after power is applied.
  3. For IPV02/IPV05 (Vacancy Sensor): Press and release the push pad to turn the lights ON.

2. Adjusting Time-Out and Light Sensitivity

To access the adjustment dials, gently remove the face cover of the sensor.

  • Selezione del tempo: Use a mini flathead screwdriver to turn the Time Selection dial.
    • Position '0' = 30 seconds (recommended for testing)
    • Position '1' = 5 minutes
    • Position '2' = 15 minutes
    • Position '3' = 30 minutes
  • Regolazione del livello di luce: Use a mini flathead screwdriver to turn the Light Level Adjustment dial.
    • Turn clockwise for lights to turn ON in lighter conditions (higher sensitivity).
    • Turn counter-clockwise for lights to turn ON in less light conditions (lower sensitivity).
    • For Vacancy Sensors (IPV series), light level sensitivity does not apply as they are manual-on.

After adjusting, replace the face cover.

3. Montaggio finale

  1. Tighten the mounting screws into the wall box.
  2. Fissare la piastra a muro.
  3. Ripristinare l'alimentazione all'interruttore automatico.

Specifiche

CaratteristicaDettaglio
MarcaLevitone
Numero di modelloIPS02-1LW
ColoreBianco
Fonte di alimentazioneElettrico con cavo
Peso dell'articolo3.2 once
Portata massima900 sq. ft. (180-degree field-of-view)
Tipo di montaggioWall switch
Dispositivi compatibiliFan, Light (Incandescent, CFL, LED, electronic low voltage, magnetic low voltage loads)
Tipo di interruttore1 via (polo singolo)
Caratteristiche specialiMotion Sensor, Auto-On/Auto-Off, No Neutral Wire Required

Risoluzione dei problemi

  • Lights do not turn off after 30 seconds (IPV Series): If lights do not turn off 30 seconds after leaving the room, decrease the sensitivity of the sensor.
  • Lights do not turn on (IPS Series): If lights do not turn on automatically when you step back into the room, increase the sensitivity of the sensor.
  • Problemi generali: If lights do not turn on or off as expected, refer to the troubleshooting section of the instructions provided with the product for detailed guidance. This may include checking wiring connections, bulb compatibility, or sensor placement.

Informazioni sulla garanzia

The Leviton Decora Motion Sensor In-Wall Switch (IPS02-1LW) comes with a Garanzia limitata di 5 anno.

Supporto

Per ulteriore supporto, informazioni sul prodotto o per view other Leviton products, please visit the official Leviton websito o contattare il loro servizio clienti.

You can find more information about Leviton sensors at leviton.com/sensors.

Documenti correlati - IPS02-1LW

Preview Guida all'installazione del sensore di presenza Leviton ODS15-IDx Designer Wall Switch
Istruzioni di installazione complete e guida per l'utente per il sensore di presenza Leviton ODS15-IDx Designer Wall Switch, che illustrano caratteristiche, configurazione, programmazione, funzionamento e risoluzione dei problemi per installazioni in una o più sedi.
Preview Guida all'app My Leviton: controlla i tuoi dispositivi Smart Home
Esplora la guida all'app My Leviton per registrare, integrare e personalizzare facilmente i tuoi dispositivi Decora Smart Wi-Fi e Leviton Load Center con Smart Breakers per un controllo della casa intelligente senza interruzioni.
Preview Specifiche del prodotto Leviton Decora Wall Switch PIR Sensori di presenza PR150-1L/PR180-1L
Specifiche e caratteristiche dettagliate dei sensori di presenza PIR Decora Wall Switch di Leviton (PR150-1L e PR180-1L), tra cui applicazione, funzionamento, installazione e dati tecnici per il controllo dell'illuminazione a risparmio energetico.
Preview Leviton DOS05/DVS05 Motion Activated Light Control Installation and Operation
Comprehensive guide for installing and operating Leviton's DOS05 and DVS05 Wide View Motion Activated Light Controls, covering single pole and 3-way applications, programming, and troubleshooting.
Preview Controlli a scorrimento Leviton Toggle: stile tradizionale, prestazioni moderne
Esplora i comandi a levetta di Leviton, inclusi i dimmer (TSL06, TSM10) e i regolatori di velocità delle ventole (TSF01). Caratterizzati da un design tradizionale e da funzionalità moderne, si adattano a diverse applicazioni di illuminazione e ventilazione. Scopri caratteristiche, specifiche e installazione.
Preview La mia guida all'app Leviton: controllo della casa intelligente per Decora Smart Wi-Fi e centri di carico
Una guida completa all'utilizzo dell'app My Leviton per la gestione dei dispositivi Leviton Decora Smart Wi-Fi e dei centri di carico Leviton con interruttori intelligenti. ...