Oakton WD-35413-00

Manuale utente del misuratore da banco Oakton WD-35413-00 pH/CON 700

Modello: WD-35413-00

1. Introduzione

The Oakton WD-35413-00 Instruments Series pH/CON 700 Benchtop Meter is a versatile laboratory instrument designed for precise measurement of pH, conductivity, and temperature. This meter is supplied with a pH electrode, a conductivity/temperature probe, and an electrode stand, operating on 110/220 VAC. It is engineered for reliable performance in various scientific and industrial applications.

Oakton WD-35413-00 pH/CON 700 Benchtop Meter with electrodes and stand

Figure 1: Oakton WD-35413-00 pH/CON 700 Benchtop Meter setup, showing the main unit, electrode stand, pH electrode, and conductivity/temperature probe immersed in a beaker.

2. Installazione e assemblaggio

Proper setup ensures accurate measurements and extends the life of your instrument. Follow these steps for initial assembly:

  1. Disimballaggio: Carefully remove all components from the packaging. Verify that all items listed in the packing list are present: the pH/CON 700 meter, pH electrode, conductivity/temperature probe, electrode stand, and power adapter.
  2. Positioning the Meter: Place the meter on a stable, level surface away from direct sunlight, heat sources, and strong electromagnetic fields.
  3. Assembling the Electrode Stand:
    • Attach the base of the stand to the main support rod.
    • Secure the electrode holder arm to the support rod at a suitable height.
    • Ensure the stand is stable and can securely hold the electrodes.
  4. Connecting Electrodes and Probes:
    • Connect the pH electrode to the designated BNC connector on the back of the meter.
    • Connect the conductivity/temperature probe to its respective port.
    • Carefully place the electrodes into the electrode holder on the stand.
  5. Collegamento elettrico: Connect the provided 110/220 VAC power adapter to the meter's power input and then to a suitable power outlet.
  6. Accensione iniziale: Premere il pulsante di accensione () to turn on the meter. The display should illuminate.

3. Istruzioni per l'uso

This section outlines the basic operation for pH and conductivity measurements.

3.1. Misurazione del pH

  1. Preparazione: Rinse the pH electrode with distilled water and gently blot dry with a lint-free tissue.
  2. Calibrazione:
    • Premere il tasto MODALITÀ pulsante per selezionare la modalità pH.
    • Premere il tasto CAL/MEAS pulsante per accedere alla modalità di calibrazione.
    • Immerse the pH electrode into the first pH buffer solution (e.g., pH 7.00). Wait for the reading to stabilize.
    • Premere ENTER/RANGE per confermare il punto di calibrazione.
    • Rinse the electrode and repeat for subsequent buffer solutions (e.g., pH 4.01 and pH 10.00).
    • Once calibration is complete, the meter will return to measurement mode.
  3. Sample Misurazione:
    • Rinse the calibrated pH electrode with distilled water.
    • Immergere l'elettrodo nella sample solution. Ensure the electrode junction is fully submerged.
    • Allow the reading to stabilize. The pH value and temperature will be displayed.
    • Premere PRESA per bloccare la lettura corrente sul display. Premere di nuovo per rilasciare.

3.2. Misurazione della conducibilità

  1. Preparazione: Rinse the conductivity/temperature probe with distilled water.
  2. Calibrazione:
    • Premere il tasto MODALITÀ button to select Conductivity mode.
    • Premere il tasto CAL/MEAS pulsante per accedere alla modalità di calibrazione.
    • Immerse the probe into a standard conductivity solution (e.g., 1413 µS/cm). Wait for the reading to stabilize.
    • Premere ENTER/RANGE per confermare il punto di calibrazione.
    • Rinse the probe and repeat for other standard solutions if multi-point calibration is desired.
  3. Sample Misurazione:
    • Rinse the calibrated conductivity probe with distilled water.
    • Immergere la sonda nel sample solution. Ensure the probe tip is fully submerged and free of air bubbles.
    • Allow the reading to stabilize. The conductivity value and temperature will be displayed.

4. Manutenzione

Regular maintenance ensures the longevity and accuracy of your Oakton pH/CON 700 meter.

  • Pulizia degli elettrodi:
    • After each use, rinse electrodes and probes thoroughly with distilled or deionized water.
    • For stubborn deposits, consult the electrode's specific cleaning instructions.
  • Conservazione degli elettrodi:
    • Store pH electrodes in a proper storage solution or pH 4 buffer. Never store dry.
    • Conductivity probes can typically be stored dry after rinsing.
  • Pulizia del contatore: Pulisci l'esterno del contatore con un pannoamp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the meter casing.
  • Frequenza di calibrazione: Calibrate the meter regularly, ideally before each measurement session or when high accuracy is required. Calibration frequency depends on usage and sample characteristics.

5. Risoluzione Dei Problemi

Fare riferimento a questa sezione per problemi comuni e le loro possibili soluzioni.

ProblemaPossibile causaSoluzione
Unstable pH readingsDirty electrode; air bubbles; electrode not conditioned; expired buffer.Clean electrode; ensure no air bubbles; recondition electrode; use fresh buffer.
Letture del pH impreciseImproper calibration; faulty electrode; temperature not compensated.Recalibrate with fresh buffers; replace electrode; ensure ATC probe is connected and functioning.
No conductivity readingProbe not connected; damaged probe; air bubbles in probe cell.Check probe connection; replace probe; tap probe to dislodge bubbles.
Il misuratore non si accendePower adapter disconnected; faulty power outlet.Controllare i collegamenti elettrici; provare una presa diversa.

6. Specifiche

Key technical specifications for the Oakton WD-35413-00 pH/CON 700 Benchtop Meter:

  • Numero modello: WD-35413-00
  • Produttore: Quercia
  • Dimensioni della confezione: 10 x 8 x 8 pollici
  • Peso del pacco: 5 libbre
  • Requisiti di potenza: 110/220 VAC (via supplied adapter)
  • Componenti inclusi: pH Electrode, Conductivity/Temperature Probe, Electrode Stand
  • Prima data disponibile: 7 marzo 2013

7. Garanzia e supporto

For warranty information and technical support, please refer to the official Oakton webo contattare il distributore autorizzato. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.

For further assistance, you may contact Oakton customer service directly. Contact details are typically available on the manufacturer's official websito.

Documenti correlati - WD-35413-00

Preview Timer OAKTON 410 con allarme: istruzioni per l'uso e specifiche
Istruzioni operative complete e specifiche per il timer con sveglia OAKTON 410 (modello WD-35002-00), che ne descrivono in dettaglio le caratteristiche, le funzioni dei pulsanti, le modalità di temporizzazione e le impostazioni della sveglia.
Preview Misuratori OAKTON ION Acorn Series: Istruzioni per l'uso e guida
Manuale operativo completo per i misuratori di pH/ioni OAKTON ION 5 e ION 6 della serie Acorn. Descrive la configurazione, la calibrazione, la misurazione, la manutenzione e la risoluzione dei problemi per un'analisi accurata della qualità dell'acqua.
Preview Istruzioni per l'uso del termometro a termocoppia serie Acorn OAKTON TEMP TC
Istruzioni per l'uso e specifiche per il termometro a termocoppia OAKTON TEMP TC Acorn Series, inclusi dettagli su misurazione, calibrazione, risoluzione dei problemi e accessori.
Preview Istruzioni per l'uso del misuratore di pH/ORP/TEMP OAKTON pH 700
Questo documento fornisce istruzioni operative complete per il misuratore di pH/ORP/TEMP OAKTON pH 700, che ne descrivono le caratteristiche, la calibrazione, le procedure di misurazione, la risoluzione dei problemi e le specifiche tecniche.
Preview Catalogo di misuratori e tester per la qualità dell'acqua Oakton | Cole-Parmer
Esplora la gamma completa di misuratori e tester della qualità dell'acqua Oakton di Cole-Parmer, dotati di soluzioni avanzate per la misurazione di pH, conduttività e ORP per analisi accurate.
Preview Manuale di istruzioni per il misuratore portatile della qualità dell'acqua Oakton serie 300
Manuale di istruzioni per i misuratori portatili della qualità dell'acqua Oakton serie 300 (modelli 350, 360, 380). Descrive funzionamento, calibrazione, manutenzione, sicurezza e specifiche per un'analisi accurata dell'acqua.