Generac 6484

Manuale utente del kit di manutenzione Generac 6484

Model: 6484 | Brand: Generac

Introduzione

The Generac 6484 Maintenance Kit is designed for Generac standby home generators with 12-18-Kilowatt 760cc - 990cc engines. Regular scheduled maintenance is essential for all standby generators to ensure optimal performance and reliability. This kit provides all the necessary components to perform routine maintenance, recommended every 200 hours of operation or every 2 years, whichever comes first. More frequent maintenance may be required if the generator operates in dusty environments.

Contenuto del kit

The Generac 6484 Maintenance Kit includes the following genuine Generac parts and accessories:

Generac 6484 Maintenance Kit components including oil filter, air filter, pre-cleaner, and two spark plugs.

Figure 1: Contents of the Generac 6484 Maintenance Kit.

Avvicinamento view of the Generac air filter, showing its yellow pleated filter material and orange frame.

Figura 2: dettagliata view of the air filter included in the kit.

Procedure di manutenzione

Performing regular maintenance helps ensure your generator operates reliably. Always refer to your generator's owner's manual for specific instructions and safety precautions before beginning any maintenance.

Preparazione generale

1. Oil Filter Replacement

The oil filter should be replaced during every scheduled maintenance interval (200 hours or 2 years).

  1. Place a drain pan beneath the oil filter to catch any oil spills.
  2. Carefully unscrew the old oil filter using an oil filter wrench.
  3. Apply a thin film of new oil to the rubber gasket of the new Generac oil filter.
  4. Avvitare manualmente il nuovo filtro dell'olio finché la guarnizione non entra in contatto, quindi serrare di un altro 1/2-3/4 di giro. Non serrare eccessivamente.
  5. Dispose of the old oil filter and drained oil responsibly according to local regulations.

2. Sostituzione del filtro dell'aria

The air filter and pre-cleaner should be inspected and replaced as part of routine maintenance.

  1. Locate the air filter housing on your generator.
  2. Open the air filter housing cover (may require unscrewing fasteners).
  3. Remove the old air filter and pre-cleaner.
  4. Install the new pre-cleaner over the new air filter.
  5. Insert the new air filter assembly into the housing, ensuring it fits securely.
  6. Chiudere e fissare il coperchio dell'alloggiamento del filtro dell'aria.

3. Sostituzione della candela

Replace spark plugs during scheduled maintenance to ensure efficient ignition.

  1. Carefully remove the spark plug wires from the existing spark plugs.
  2. Use a spark plug wrench to loosen and remove the old spark plugs.
  3. Inspect the new spark plugs. While often pre-gapped, it is recommended to verify the gap according to your generator's owner's manual (e.g., 0.020" for 816cc engines).
  4. Thread the new spark plugs into the engine by hand to prevent cross-threading.
  5. Tighten with a spark plug wrench. Do not overtighten.
  6. Ricollegare saldamente i cavi delle candele.

4. Oil Change (Oil Funnel Use)

While the kit includes an oil funnel, engine oil is sold separately. Always use the recommended oil type and viscosity for your generator model.

  1. Ensure the generator engine is warm to facilitate oil drainage.
  2. Posizionare un contenitore adatto sotto il tappo di scarico dell'olio.
  3. Rimuovere il tappo di scarico dell'olio e lasciare che tutto l'olio vecchio fuoriesca completamente.
  4. Reinstall the oil drain plug securely.
  5. Using the provided oil funnel, slowly add the recommended amount and type of new engine oil.
  6. Check the oil level using the dipstick and add more if necessary, ensuring it is within the proper range.

5. General Cleaning (Chamois Use)

Use the chamois to clean any spills or debris around the engine and components after maintenance. A clean generator is easier to inspect and maintain.

Prodotto finitoview Video

Video 1: Un prodotto completo suview of the Generac 6484 Maintenance Kit, detailing its components and benefits for generator upkeep.

Maintenance Kit Components Preview

Video 2: Una breve premessaview mostrareasing the individual components included in the Generac 6484 Maintenance Kit.

Specifiche

CaratteristicaDettaglio
MarcaGenerazione
Nome del modello6484
CompatibilitàGenerac 12-18 kW Generators with 760cc-990cc Engines
Intervallo di manutenzioneOgni 200 ore o 2 anni
Componenti inclusiPre-cleaner, Air filter, Oil filter, Oil funnel, (2) Spark plugs, Chamois
Peso dell'articolo1.28 libbre (0.58 chilogrammi)
Dimensioni del prodotto7 cm L x 7 cm P x 6 cm A
Paese di origineU.S.A.
Codice UPC696471064841

Risoluzione dei problemi comuni

While this kit is for preventative maintenance, understanding common issues can help. Always consult your generator's main owner's manual for detailed troubleshooting steps.

Garanzia e supporto

Generac stands behind its maintenance kits with a one-year warranty, ensuring quality and reliability for your generator's upkeep.

For further assistance, detailed troubleshooting, or to locate authorized service centers, please refer to your primary Generac generator owner's manual or visit the official Generac website. You can also contact Generac customer support directly for product-specific inquiries.

Documenti correlati - 6484

Preview Generatori Generac: soluzioni portatili, residenziali e commerciali
Esplora la gamma completa di generatori Generac, inclusi sistemi portatili, residenziali e commerciali. Scopri caratteristiche, specifiche e applicazioni per soluzioni di alimentazione affidabili.
Preview Manuale del proprietario dei generatori raffreddati ad aria Generac da 60 Hz (da 10 kW a 28 kW)
Manuale completo del proprietario per i generatori raffreddati ad aria Generac da 60 Hz, che copre sicurezza, funzionamento, manutenzione e risoluzione dei problemi per i modelli da 10 kW a 28 kW.
Preview Manuale d'uso dei generatori raffreddati ad aria Generac 60 Hz (10 kW - 26 kW)
Questo manuale completo del proprietario di Generac fornisce indicazioni essenziali per il funzionamento sicuro, la manutenzione e la risoluzione dei problemi dei generatori di riserva raffreddati ad aria da 60 Hz, coprendo modelli da 10 kW a 26 kW.
Preview Manuale del proprietario dei generatori raffreddati ad aria Generac da 60 Hz (da 10 kW a 28 kW)
Comprehensive owner's manual for Generac 60 Hz air-cooled standby generators, covering models from 10 kW to 28 kW. Includes safety information, general specifications, operation, maintenance, and troubleshooting.
Preview Generac 60 Hz Air-Cooled Generator Installation Guidelines (9 kW to 22 kW)
Comprehensive installation guidelines for Generac 60 Hz air-cooled generators, covering models from 9 kW to 22 kW. Includes safety, site selection, fuel and electrical connections, and start-up procedures.
Preview Manuale del proprietario del generatore raffreddato ad aria Generac 60 Hz (10 kW - 24 kW)
Manuale d'uso completo per i generatori raffreddati ad aria Generac a 60 Hz (da 10 kW a 24 kW), che tratta argomenti quali sicurezza, funzionamento, manutenzione e risoluzione dei problemi. Include specifiche dettagliate e istruzioni operative.