1. Introduzione
This instruction manual provides essential information for the installation, operation, and maintenance of the Trane White Rodgers Upgraded Furnace Control Circuit Board, model 50A55-486. This board is designed as a direct replacement for the older part # 50A55-486 and is compatible with Trane and American Standard furnaces. Please read this manual thoroughly before proceeding with installation or service.
2. Informazioni sulla sicurezza
WARNING: Electrical shock hazard. Disconnect all power to the furnace before installing or servicing this control board. Failure to do so can result in serious injury or death.
- Always ensure the main power supply to the furnace is turned off at the circuit breaker or fuse box before beginning any work.
- Only qualified technicians should perform installation and service.
- Verify all wiring connections are secure and correct before restoring power.
- Non bypassare alcun dispositivo di sicurezza.
3. Prodotto finitoview
The White Rodgers 50A55-486 is an upgraded furnace control circuit board designed to manage the various functions of your furnace, including ignition, blower operation, and safety protocols. It serves as a direct replacement for the original 50A55-486 part.

Figure 1: White Rodgers 50A55-486 Furnace Control Circuit Board. This image displays the top view of the circuit board, showing various terminals, relays, and components. The board is white with green circuit traces and features multiple connection points for furnace wiring.
4. Installazione e configurazione
- Disconnessione dell'alimentazione: Before starting, ensure all electrical power to the furnace is completely disconnected at the main service panel.
- Accedi al Pannello di Controllo: Individuare e aprire il pannello di accesso alla fornace per esporre la scheda di controllo esistente.
- Documentare il cablaggio esistente: It is highly recommended to take clear photographs of all wiring connections to the old control board before disconnecting them. Labeling wires can also prevent errors during reinstallation.
- Rimuovere la vecchia scheda: Carefully disconnect all wires and mounting screws from the old control board. Note that the new board may have slightly different component layouts or terminal positions compared to the original.
- Installa la nuova scheda: Mount the new White Rodgers 50A55-486 control board in the same location as the old one. Secure it with appropriate fasteners.
- Collegare il cablaggio: Refer to your documented wiring (photos/labels) and the wiring diagram provided with your furnace or the new control board. Connect all wires to their corresponding terminals on the new board. Pay close attention to the "TWIN Y W R G C" terminals and "LINE NEUTRAL" connections.
- Verifica connessioni: Double-check all connections for tightness and correctness. Ensure no wires are loose or incorrectly placed.
- Ripristina alimentazione: Close the furnace access panel. Restore electrical power to the furnace at the main service panel.
- Operazione di prova: Initiate a heating cycle to verify proper furnace operation.
Note: Some users have reported that while this board is a direct replacement, the physical layout of terminals might differ slightly from older versions. Always cross-reference with your furnace's wiring diagram.
5. Funzionamento
The furnace control board manages the sequence of operations for your heating system. A typical heating cycle involves:
- Richiesta di riscaldamento tramite termostato: When the thermostat calls for heat, the control board initiates the heating sequence.
- Attivazione del motore induttore: The inducer motor starts to vent combustion gases.
- Chiusura del pressostato: Una volta che si è stabilito un tiraggio sufficiente, il pressostato si chiude, segnalando alla scheda di controllo di procedere.
- Sequenza di accensione: The igniter is energized, followed by the opening of the gas valve.
- Rilevamento della fiamma: The control board verifies the presence of a flame.
- Blower Motor Activation: After a short delay, the main blower motor starts to distribute heated air.
- Heating Cycle Completion: When the thermostat's set temperature is reached, the gas valve closes, the igniter de-energizes, and after a cool-down period, the blower motor shuts off.
Video 1: Oltreview of a Furnace Control Circuit Board. This video provides a visual demonstration and explanation of a furnace control board, highlighting its components and general function within a heating system. While the specific model shown may vary, the operational principles are similar.
6. Manutenzione
Regular maintenance helps ensure the longevity and efficient operation of your furnace and its control board.
- Ispezione annuale: Have a qualified HVAC technician inspect your furnace annually.
- Pulizia: Keep the area around the furnace clean and free of dust and debris. Dust accumulation on the control board can lead to overheating or malfunctions.
- Integrità del cablaggio: Periodically check for any loose or corroded wiring connections.
- Sostituzione del filtro dell'aria: Regularly replace or clean your furnace's air filter to ensure proper airflow and prevent strain on the system.
7. Risoluzione Dei Problemi
The control board often includes an LED indicator to assist with troubleshooting. Refer to the specific diagnostic codes for your furnace model, which are typically found on the furnace door or in your furnace's manual.
Common Issues and Potential Solutions:
- Nessun calore:
- Controllare le impostazioni del termostato.
- Verify power supply to the furnace.
- Inspect the furnace filter for blockage.
- Controllare che gli interruttori automatici non siano scattati o che i fusibili siano bruciati.
- Observe the LED indicator for diagnostic codes.
- Soffiatore non funzionante:
- Ensure the thermostat is set to "AUTO" or "ON" as desired.
- Check for obstructions in the blower compartment.
- Listen for any unusual noises from the blower motor.
- Funzionamento intermittente:
- Could indicate a loose connection or a failing component.
- Verificare la corretta messa a terra.
If you are unable to resolve an issue, contact a qualified HVAC technician for assistance.
8. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Marca | Trane |
| Nome del modello | 50A55-486 |
| Numero di parte | OEM Upgrd Replm. for Part # 50A55-486 |
| Peso dell'articolo | 12.6 once |
| Dimensioni del prodotto | 4 x 4 x 6 pollici |
| Tipo di installazione | Screw-in or Snap-in |
| Tipo di materiale | Rame |
| Consolle di controllo | Pomello (Note: This specification seems generic and may not directly apply to the circuit board itself, but rather the furnace it controls.) |
| Colore | Bianco |
| Data prima disponibilità | 4 giugno 2010 |
9. Garanzia e supporto
For warranty information and technical support, please refer to the documentation provided with your specific product packaging or contact the manufacturer directly. As this is a replacement part, warranty terms may vary.