Trane PSE-T19

Manuale di istruzioni del sensore di fiamma per forno Trane PSE-T19

Model: PSE-T19 (Part Number: SEN01114_v4)

1. Introduzione

This manual provides essential information for the proper installation, operation, maintenance, and troubleshooting of the Trane Furnace Flame Sensor, model PSE-T19. This component is a critical safety device designed to ensure the safe and efficient operation of your furnace. Please read this manual thoroughly before attempting any procedures.

2. Informazioni sulla sicurezza

AVVERTENZA: installazione, regolazione, alterazione, assistenza o manutenzione non corrette possono causare danni materiali, lesioni o morte. Leggere attentamente le istruzioni di installazione, funzionamento e manutenzione prima di installare o sottoporre a manutenzione questa apparecchiatura.

  • Always disconnect electrical power to the furnace before performing any service or maintenance.
  • Working with gas appliances can be hazardous. If you are not qualified to perform these procedures, contact a certified HVAC technician.
  • Indossare adeguati dispositivi di protezione individuale (DPI), come guanti e protezioni per gli occhi.
  • Ensure all gas connections are properly sealed and tested for leaks after any work involving gas lines.
  • Non bypassare alcun dispositivo di sicurezza.

3. Prodotto finitoview

The flame sensor is a safety device in a gas furnace that detects the presence of a flame in the burner assembly. If the sensor does not detect a flame after the gas valve opens, it signals the furnace control board to shut off the gas supply, preventing unburnt gas from accumulating. This specific sensor is an upgraded replacement for Trane part number SEN01114.

Image of the Trane Furnace Flame Sensor PSE-T19

Figure 1: Trane Furnace Flame Sensor PSE-T19
This image displays the Trane Furnace Flame Sensor PSE-T19. It features a white ceramic insulator body, a metal mounting bracket with a screw hole, and a metal rod that extends into the flame path to detect the presence of a flame.

4. Configurazione e installazione

Installation of the flame sensor should only be performed by a qualified technician. The following steps are for informational purposes only.

  1. Scollegare l'alimentazione: Turn off all electrical power to the furnace at the main service panel.
  2. Locate Sensor: Identify the existing flame sensor. It is typically a single metal rod positioned in the flame path of the burner assembly, often secured by one screw.
  3. Rimuovere il vecchio sensore: Carefully disconnect the wire leading to the sensor. Remove the screw holding the sensor in place and gently pull the old sensor out.
  4. Installare il nuovo sensore: Insert the new Trane PSE-T19 flame sensor into the same position. Ensure the metal rod is correctly positioned to be enveloped by the flame during operation. Secure it with the mounting screw.
  5. Collegare il cablaggio: Reconnect the wire to the new flame sensor. Ensure the connection is secure.
  6. Ripristina alimentazione: Accendere l'energia elettrica al forno.
  7. Operazione di prova: Initiate a heating cycle and observe the furnace's ignition sequence. The main burners should ignite and remain lit.

5. Principi operativi

When the furnace calls for heat, the igniter heats up, and the gas valve opens. As the gas ignites, the flame sensor, which is a small metal rod, becomes exposed to the flame. The flame rectifies a small alternating current (AC) into a direct current (DC) signal. This DC signal is sent to the furnace's control board, confirming the presence of a flame. If the control board does not receive this signal within a few seconds of ignition, it will shut off the gas supply as a safety measure, preventing unburnt gas from accumulating in the combustion chamber.

6. Manutenzione

Regular maintenance of the flame sensor is crucial for reliable furnace operation. A dirty flame sensor is a common cause of furnace malfunctions.

  • Pulizia: Annually, or if experiencing ignition issues, carefully remove the flame sensor. Use fine-grit sandpaper or steel wool to gently clean off any carbon buildup or oxidation from the ceramic insulator and the metal rod. Do not use harsh chemicals or abrasive cleaners that could damage the sensor.
  • Ispezione: While cleaning, inspect the sensor for any signs of physical damage, such as cracks in the ceramic, corrosion, or a bent rod. Replace the sensor if any damage is observed.
  • Reinstallazione: Reinstall the cleaned sensor, ensuring it is securely mounted and the wire connection is tight.

7. Risoluzione Dei Problemi

If your furnace is experiencing issues related to ignition or short cycling, the flame sensor may be a contributing factor.

  • Furnace Ignites, then Shuts Off (Short Cycling): This is a classic symptom of a dirty or faulty flame sensor. The sensor detects the flame initially but then loses the signal, causing the furnace to shut down.
  • Furnace Fails to Ignite: While many factors can cause this, a completely failed flame sensor can prevent the furnace from even attempting to keep the gas valve open.

Passaggi per la risoluzione dei problemi:

  1. Clean the Flame Sensor: Follow the cleaning instructions in Section 6. This resolves most flame sensor-related issues.
  2. Controllare il cablaggio: Ensure the wire connecting the flame sensor to the control board is secure and free from damage.
  3. Ispezionare per danni: Look for any visible damage to the sensor itself.
  4. Test for Continuity (Advanced): A qualified technician can use a multimeter to test the sensor's continuity and signal output.
  5. Sostituire il sensore: If cleaning and inspection do not resolve the issue, and the sensor is suspected to be faulty, replace it with a new Trane PSE-T19 or equivalent part.

8. Specifiche

AttributoValore
Numero di modelloPSE-T19 (SEN01114_v4)
ProduttoreTrane
Dimensioni del prodotto6 x 6 x 6 pollici
Peso dell'articolo0.53 once
ASINB00ECEERIG

9. Informazioni sulla garanzia

Warranty coverage for the Trane Furnace Flame Sensor PSE-T19 is typically provided by the seller or manufacturer at the time of purchase. Please refer to your purchase documentation or contact the original point of sale for specific warranty terms and conditions.

10. Supporto

For technical assistance, installation guidance, or troubleshooting beyond the scope of this manual, please contact the seller or a qualified HVAC professional. Ensure you have your product model number (PSE-T19 or SEN01114_v4) and purchase details available when seeking support.

Documenti correlati - PSE-T19

Preview Forno a gas orizzontale a flusso ascendente/discendente Trane XL 80: specifiche e caratteristiche
Guida completa ai forni a gas Trane serie XL 80 (modelli TUD2 e TDD2), che descrive in dettaglio caratteristiche, dati sulle prestazioni, specifiche elettriche e dimensioni per installazioni a flusso ascendente, discendente e orizzontale.
Preview Manuale di installazione, funzionamento e manutenzione della caldaia a gas Trane & American Standard serie S8
Guida completa per l'installazione, il funzionamento e la manutenzione delle caldaie a gas a flusso ascendente/discendente/orizzontale Trane e American Standard serie S8 1-Stage e 2-StagForni a tiraggio indotto con motore ad alta efficienza. Include avvertenze di sicurezza, specifiche, schemi elettrici e risoluzione dei problemi.
Preview Forno a gas ad alta efficienza Trane XT95: specifiche e caratteristiche
Dati dettagliati del prodotto, caratteristiche, vantaggi, specifiche, dati sulle prestazioni, schemi elettrici e dimensioni per la serie Trane XT95 di unità monoblocco ad alta efficienzatage, forni a gas a condensazione, a ventilazione diretta, assistiti da ventilatore.
Preview Bollettino di servizio guasti scheda IFC Trane e American Standard - Rielaborazione OBBLIGATORIA
Bollettino di servizio ufficiale di Trane e American Standard relativo ai guasti della scheda Integrated Furnace Control (IFC) in specifici modelli di forni. Dettagli sul codice di errore 5, sui modelli interessati e sulle istruzioni di rilavorazione obbligatorie.
Preview Forno a gas Trane serie S9V2: Manuale di installazione, funzionamento e manutenzione
Guida completa per l'installazione, il funzionamento e la manutenzione della serie 2-s Trane e American Standard S9V2tagForni a gas a condensazione a velocità variabile. Tratta argomenti di sicurezza, procedure di installazione, specifiche e risoluzione dei problemi.
Preview Trane S9V2 Serie Due Stage Dati di prodotto della caldaia a condensazione a gas
Dati e specifiche dettagliate del prodotto per la serie Trane S9V2 Two Stage Forno a condensazione a gas, che illustra caratteristiche, vantaggi, varianti di modello, specifiche tecniche e tabelle delle prestazioni del flusso d'aria.