1. Prodotto finitoview
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Trane 3 x 18" CCW Fan Blade. This fan blade is a brand new replacement part designed for HVAC condenser units, featuring a 3-blade configuration and a 24-inch length, with counter-clockwise rotation.

Image 1.1: The Trane 3-blade HVAC condenser fan blade. This image shows the metallic fan blade with three distinct blades radiating from a central hub, designed for counter-clockwise rotation in HVAC condenser units.
2. Guida all'installazione (configurazione)
La sicurezza prima di tutto: Before attempting any installation or maintenance, ensure the HVAC unit's power supply is completely disconnected at the circuit breaker. Failure to do so can result in serious injury or death. Wear appropriate personal protective equipment (PPE), including gloves and eye protection.
Strumenti necessari:
- Wrench set or socket set
- Cacciavite (a croce o a taglio, a seconda delle necessità)
- Guanti
- Occhiali di sicurezza
Fasi di installazione:
- Scollegare l'alimentazione: Turn off the main power to the HVAC condenser unit at the electrical panel. Verify power is off using a voltagetester.
- Accesso al vano ventola: Carefully remove the top grille or access panel of the condenser unit to expose the fan motor and blade assembly. Note the orientation of the existing fan blade.
- Remove Old Fan Blade: Loosen the set screw(s) on the fan blade hub that secure it to the motor shaft. Carefully slide the old fan blade off the motor shaft. If the blade is stuck, a penetrating lubricant may be needed.
- Ispezionare l'albero motore: Clean the motor shaft of any debris or corrosion.
- Install New Fan Blade: Slide the new Trane fan blade onto the motor shaft. Ensure the blade is oriented correctly for counter-clockwise rotation (CCW). The flat side of the blade hub should align with the flat side of the motor shaft, if applicable.
- Secure Fan Blade: Position the fan blade at the correct height on the shaft (refer to the original blade's position or manufacturer's specifications for the unit). Tighten the set screw(s) firmly to secure the blade to the motor shaft. Ensure the blade is level and does not wobble.
- Controllare l'autorizzazione: Manually rotate the fan blade to ensure it spins freely without hitting any part of the condenser unit housing or wiring.
- Rimontare l'unità: Replace the top grille or access panel, ensuring all screws are tightened.
- Ripristina alimentazione: Turn the main power back on at the electrical panel.
- Operazione di prova: Start the HVAC unit and observe the fan blade operation. Listen for unusual noises or vibrations.
3. Funzionamento
The Trane 3 x 18" CCW Fan Blade is designed to work in conjunction with your HVAC condenser motor to facilitate heat exchange. When the condenser unit is active, the motor drives the fan blade, drawing air across the condenser coils. This airflow helps dissipate heat from the refrigerant, allowing the air conditioning system to cool effectively. The counter-clockwise rotation ensures proper airflow direction for optimal system performance.
4. Manutenzione
Regular maintenance of the fan blade can extend its lifespan and ensure efficient operation of your HVAC system. Always disconnect power before performing any maintenance.
- Pulizia annuale: At least once a year, or more frequently in dusty environments, clean the fan blades. Dust and debris accumulation can unbalance the blade and reduce airflow efficiency. Use a soft brush or cloth to gently wipe down the blades.
- Ispezionare per danni: Periodically inspect the fan blade for any signs of damage, such as bends, cracks, or corrosion. A damaged blade can lead to imbalance, excessive vibration, and premature motor failure.
- Check Set Screws: Ensure the set screws securing the blade to the motor shaft remain tight. Loose screws can cause the blade to slip or wobble.
- Lubrificazione: The fan blade itself does not require lubrication. Any lubrication needs would be for the fan motor bearings, as specified by the motor manufacturer.
5. Risoluzione Dei Problemi
This section addresses common issues related to the fan blade. For complex issues, consult a qualified HVAC technician.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Rumore/vibrazioni eccessivi | Unbalanced blade (debris, damage), loose set screws, worn motor bearings. | Clean blades, inspect for damage, tighten set screws. If motor bearings are suspected, consult a technician. |
| La ventola non gira | No power to unit, faulty motor, seized blade (obstruction), capacitor issue. | Check power supply, remove obstructions. For motor or capacitor issues, professional diagnosis is required. |
| Flusso d'aria ridotto | Dirty coils, incorrect blade rotation, motor running slow. | Clean condenser coils, verify correct CCW rotation, check motor speed. |
6. Specifiche
| Attributo | Dettaglio |
|---|---|
| Marca | Trane |
| Numero di modello (ASIN) | B00EKSWD2Q |
| Dimensioni del prodotto | 24 x 7 x 24 pollici |
| Peso dell'articolo | 6 libbre |
| Numero di lame | 3 |
| Rotazione | Counter-Clockwise (CCW) |
| Produttore | LAU |
| Paese di origine | U.S.A. |
| Dispositivi compatibili | Commercial Building, Residential Building HVAC Condensers |
7. Garanzia e supporto
This Trane replacement fan blade is designed for durability and performance. Specific warranty details may vary depending on the seller and purchase date. Please retain your proof of purchase for any warranty claims.
For technical support, installation assistance, or warranty inquiries, please contact the seller or a certified HVAC professional. You may also visit the official Trane website for general product information and authorized service providers.
Informazioni sui contatti:
- Seller: North America HVAC (as per product listing)
- General Trane Information: www.trane.com