SDC 1091AIV

SDC 1091AIV SpaceSaver Electric Bolt Lock

Manuale di istruzioni

Model: 1091AIV

1. Prodotto finitoview

The SDC 1091AIV SpaceSaver Electric Bolt Lock is an advanced locking solution designed for access control applications. Its unique design allows the stainless steel bolt to project at right angles to the lock mechanism, facilitating installation in standard 1.75-inch frames or most door lock stiles with a simple cutout. This concealed installation enhances both aesthetics and security.

Caratteristiche principali:

  • Adjustable auto relock switch
  • Fits 1-3/4-inches minimum face frames
  • Failsafe - 12/24VDC standard operation
  • Failsecure - choice of 12 or 24VDC operation
  • Aluminum finish standard
SDC 1091AIV SpaceSaver Electric Bolt Lock

Image 1: The SDC 1091AIV SpaceSaver Electric Bolt Lock, showcasing its narrow profile and bolt mechanism, alongside its strike plate.

2. Informazioni sulla sicurezza

Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in product damage, property damage, or personal injury.

  • Installazione professionale: Installation of this electric bolt lock should be performed by qualified personnel familiar with electrical systems and door hardware.
  • Sicurezza elettrica: Ensure power is disconnected before performing any wiring or maintenance. Verify correct voltage (12VDC or 24VDC) is supplied to prevent damage to the unit.
  • Voltage Compatibilità: This unit operates on 12VDC or 24VDC. Connecting to an incorrect voltage source will damage the lock.
  • Elenco UL: This product is UL listed and UL 10C positive pressure compliant. Adhere to all local building codes and regulations during installation.

3. Configurazione e installazione

3.1 Lista di controllo pre-installazione

  • Verify door frame material and dimensions. A minimum 1-3/4 inch frame is required.
  • Ensure appropriate power supply (12VDC or 24VDC) is available.
  • Gather necessary tools: measuring tape, drill, appropriate drill bits, screwdriver set, wiring tools.

3.2 Mounting the Lock

  1. Carefully measure and mark the desired location for the lock body and strike plate on the door frame and door edge, respectively.
  2. Create the necessary cutout in the door frame for the lock body. The SpaceSaver design allows for a simple cutout.
  3. Secure the lock body into the cutout using the provided fasteners. Ensure it is flush with the frame surface for proper operation and aesthetics.
  4. Install the strike plate on the door edge, aligning it precisely with the bolt mechanism of the lock.

3.3 Cablaggio

The SDC 1091AIV supports both Failsafe and Failsecure configurations. Determine the required operation before wiring.

  • Failsafe Operation: The lock will unlock when power is removed. This is typically used for egress doors where safety requires the door to open during a power failure. Connect the power supply according to the Failsafe wiring diagram provided with the product packaging.
  • Failsecure Operation: The lock will remain locked when power is removed. This is typically used for security applications where the door must remain secured during a power failure. Connect the power supply according to the Failsecure wiring diagram provided with the product packaging.
  • Assicurarsi che tutti i collegamenti elettrici siano sicuri e isolati per evitare cortocircuiti.

3.4 Regolazioni

The lock features an adjustable auto relock switch. Refer to the detailed instructions in the product packaging for specific adjustment procedures to fine-tune the relock timing.

4. Istruzioni per l'uso

The SDC 1091AIV Electric Bolt Lock operates in conjunction with an access control system or a simple switch, depending on the installation configuration.

  • To Unlock (Failsafe): Apply power to the lock. The bolt will retract, allowing the door to open. Removing power will cause the bolt to extend, locking the door.
  • To Unlock (Failsecure): Remove power from the lock. The bolt will retract, allowing the door to open. Applying power will cause the bolt to extend, locking the door.
  • The adjustable auto relock switch will automatically extend the bolt after a set delay once the door is closed and aligned with the strike plate.

5. Manutenzione

Regular maintenance ensures optimal performance and longevity of your SDC 1091AIV Electric Bolt Lock.

  • Ispezione: Periodically inspect the lock body, bolt, and strike plate for any signs of wear, damage, or misalignment. Ensure all fasteners are tight.
  • Pulizia: Clean the exterior surfaces with a soft, dry cloth. Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.
  • Lubrificazione: If the bolt mechanism appears stiff or noisy, a small amount of silicone-based lubricant can be applied to the moving parts. Do not over-lubricate.
  • Controllo del cablaggio: Annually, inspect wiring connections for any signs of corrosion or loose terminals.

6. Risoluzione Dei Problemi

If you encounter issues with your SDC 1091AIV Electric Bolt Lock, refer to the following troubleshooting guide:

ProblemaPossibile causaSoluzione
Lock not engaging/disengagingNo power, incorrect wiring, bolt obstruction, misalignment.Check power supply, verify wiring against diagram, ensure no physical obstructions, adjust lock/strike plate alignment.
Funzionamento intermittenteLoose wiring connections, fluctuating power supply, worn components.Secure all wiring connections, test power supply stability, inspect for wear.
Rumore eccessivo durante il funzionamentoLack of lubrication, mechanical interference, worn parts.Apply a small amount of silicone lubricant to moving parts, check for obstructions, consider professional inspection if noise persists.
Auto relock not functioningIncorrect adjustment, sensor issue, door not closing properly.Adjust the auto relock switch settings, ensure the door closes fully and aligns with the strike plate.

If troubleshooting steps do not resolve the issue, contact SDC technical support or a qualified technician.

7. Specifiche

CaratteristicaDettaglio
MarcaSDC
Nome del modelloSalvaspazio
Numero di parte1091AIV
Tipo di bloccoElectric Mortise Lock
MaterialeAlluminio
ColoreAcciaio inossidabile
Fonte di alimentazioneDC (12VDC / 24VDC)
Caratteristica specialeBlocco chiave
Peso dell'articolo1.45 libbre
Dimensioni del pacco10.8 x 3.4 x 2.4 pollici
Minimum Frame Fit1-3/4 pollici
Metodo di controlloApp (as per product specifications, verify compatibility with specific access control systems)
CertificazioniUL Listed, UL 10C Positive Pressure Compliant

8. Garanzia e supporto

For specific warranty information regarding your SDC 1091AIV SpaceSaver Electric Bolt Lock, please refer to the documentation included with your purchase or contact the seller or manufacturer directly.

For technical assistance, installation support, or to report any issues, please contact SDC customer service through their official websito o le informazioni di contatto fornite al momento dell'acquisto.

Documenti correlati - 1091AIV

Preview Guida all'installazione della serratura a mortaio nascosta extra stretta Failsafe SDC 1490AI
Istruzioni di installazione dettagliate per la serratura a mortaio nascosta extra stretta Failsafe SDC 1490AI, inclusi schemi elettrici, specifiche tecniche e suggerimenti per la risoluzione dei problemi.
Preview Istruzioni per l'installazione della serratura a mortaio nascosta extra stretta Failsecure SDC 2490AH
Guida completa all'installazione della serratura a catenaccio a scomparsa SDC 2490AH, che copre il montaggio sopraelevato e laterale, le configurazioni di cablaggio con e senza il regolatore di potenza PR-1000, la risoluzione dei problemi e i riferimenti dimensionali.
Preview Istruzioni per l'installazione della serratura a mortaio nascosta Fail-Secure SDC 1291AHWD
Questo documento fornisce istruzioni dettagliate per l'installazione della serratura a chiavistello a scomparsa SDC 1291AHWD Fail-Secure, incluse procedure di montaggio orizzontale e verticale, schemi elettrici, specifiche elettriche e guida alla risoluzione dei problemi. Descrive inoltre l'utilizzo del regolatore di potenza PR-1000 e dell'interruttore ARS.
Preview SDC 1190AIWD Fail-Safe Concealed Mortise Bolt Lock Installation Guide
Comprehensive installation instructions for the SDC 1190AIWD Fail-Safe Concealed Mortise Bolt Lock, including wiring diagrams, technical specifications, and troubleshooting tips.
Preview Istruzioni per l'installazione della serratura a mortaio nascosta a prova di errore SDC 1091AI/1091AIDL
Guida completa all'installazione per le serrature a mortasa a scomparsa a prova di guasto SDC 1091AI e 1091AIDL. Include istruzioni dettagliate per il montaggio a soffitto e a montante laterale, schemi elettrici, risoluzione dei problemi e specifiche tecniche.
Preview SDC 1291AH Fail-Secure Concealed Mortise Bolt Lock Installation Instructions
Comprehensive installation guide for the SDC 1291AH Fail-Secure Concealed Mortise Bolt Lock. Covers overhead and sidejamb installation, wiring configurations with and without the PR-1000 Power Regulator, troubleshooting tips, and detailed technical specifications for metal doors and frames.