Introduzione
The Extech PRC30 is a handheld multifunction process calibrator designed for verifying the operation of various industrial instruments. It is suitable for use with sensors, thermocouple probes, controllers, panel meters, and other testing tools, particularly in temperature control and process troubleshooting applications.

Figura 1: Fronte view of the Extech PRC30 Multifunction Process Calibrator, highlighting its display and control panel.
Caratteristiche del prodotto
- Multifunction capability for various process calibration tasks.
- Handheld design for portability and ease of use.
- Dot matrix LCD for clear display of readings and settings.
- Intuitive button layout for operation.
Impostare
Installazione della batteria
- Individuare il coperchio del vano batteria sul retro del dispositivo.
- Aprire il coperchio facendolo scorrere o svitandolo come indicato.
- Insert the required batteries (type not specified, but typically AA or AAA) ensuring correct polarity.
- Riposizionare saldamente il coperchio del vano batteria.
Istruzioni per l'uso
Controlli e display sopraview
The Extech PRC30 features a clear dot matrix LCD and a user-friendly control panel. Refer to Figure 1 for button locations.
- Power Button (Orange, circular with power symbol): Press to turn the calibrator ON or OFF.
- Pulsanti freccia (su, giù, sinistra, destra): Used for navigation, adjusting values, and selecting options.
- Pulsante IMPOSTA: Conferma le selezioni o accede ai menu delle impostazioni.
- UNIT Button (under TYPE): Changes the measurement unit (e.g., °F, °C).
- I/O Button (under MODE): Toggles between input and output modes.
- MEM Button (under STEP): Accesses memory functions, such as saving or recalling data.
- ZERO Button (under ZERO, with lightbulb symbol): Performs zero adjustment or backlight control.
- CJC (Cold Junction Compensation) Indicator: Indicates the status of cold junction compensation.
- APO (Auto Power Off) Indicator: Shows if the auto power off function is active.
- SOURCE Indicator: Indicates the device is in source mode.
- MEM.25 Indicator: Likely indicates a memory location or a specific memory function.
Funzionamento di base
- Accensione: Press the orange power button. The display will illuminate.
- Selezione della modalità: Use the MODE (I/O) button to switch between input and output functions as required for your calibration task.
- Regolazione dei valori: Use the Up/Down arrow buttons to adjust output values or navigate through menu options. The Left/Right arrow buttons may be used for digit selection or fine-tuning.
- Modifica delle unità: Press the UNIT button to cycle through available measurement units (e.g., °F, °C).
- Regolazione zero: Use the ZERO button to perform a zero adjustment for current measurements or to activate the display backlight.
- Funzioni di memoria: Press the MEM button to save current readings or recall previously stored data.
- Spegni: Press and hold the orange power button until the display turns off. The Auto Power Off (APO) function will also turn off the device after a period of inactivity.
Manutenzione
- Pulizia: Pulire il dispositivo con un panno morbido, damp panno. Non usare detergenti abrasivi o solventi.
- Magazzinaggio: Store the calibrator in a dry, cool environment when not in use. Remove batteries if storing for extended periods to prevent leakage.
- Sostituzione della batteria: Replace batteries promptly when the low battery indicator appears on the display to ensure accurate operation.
- Calibrazione: Per mantenere la precisione delle misurazioni, si consiglia di effettuare una calibrazione regolare da parte di personale qualificato.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il dispositivo non si accende. | Batterie scariche o installate in modo errato. | Controllare la polarità delle batterie e sostituirle con batterie nuove. |
| Letture imprecise. | Needs calibration; environmental interference; incorrect settings. | Perform zero adjustment; ensure stable environment; verify measurement settings; consider professional calibration. |
| Il display è vuoto o poco luminoso. | Batteria scarica; retroilluminazione spenta. | Replace batteries; press the ZERO button to activate backlight. |
Specifiche
- Modello: PRC30
- Descrizione: Calibratore di processo multifunzione
- Tipo di visualizzazione: LCD a matrice di punti
- Dimensioni (lunghezza x larghezza x altezza): 6.375 pollici (15.9 cm) x 3.25 pollici (8 cm) x 1.75 pollici (4.4 cm)
- Intervallo di temperatura di esercizio: da 41 a 104 °F (da 5 a 40 °C)
- Intervallo di umidità operativa: <80% UR
- Fonte di energia: Batterie
- Origine: Fatto a Taiwan
Garanzia e supporto
The Extech PRC30 Multifunction Process Calibrator comes with a 1-Year Universal Guarantee.
For technical support, service, or warranty claims, please refer to the contact information provided with your purchase documentation or visit the official Extech Instruments websito.