1. Prodotto finitoview
The Aiphone LEF-10S is an Open Voice Selective Call Master Intercom designed for surface mounting. It facilitates audio communication with visitors at a door and with other rooms within a building. This master intercom supports connection with up to 10 Aiphone LAF and LEF Series master intercoms, and LA, LE, or LS Series door and sub-master intercoms.
Key features include an All-Call button for broadcasting messages and a Door Release button for remote access control.

Image of the Aiphone LEF-10S Open Voice Selective Call Master Intercom, showing its front panel with buttons and speaker.
1.1 Cosa c'è nella scatola?
- Aiphone LEF-10S master intercom unit
- Hardware di montaggio
- Manuale di istruzioni
2. Informazioni sulla sicurezza
Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or damage to the product.
- Sicurezza elettrica: Ensure all power is disconnected before performing any wiring or installation procedures. Installation should be performed by qualified personnel in accordance with all local electrical codes.
- Condizioni ambientali: Do not expose the intercom to extreme temperatures, humidity, or direct water contact.
- Gestione: Maneggiare l'unità con cura per evitare danni fisici.
3. Installazione
The LEF-10S master intercom is designed for surface mounting.
3.1 Montaggio
- Select a suitable location for the master intercom, ensuring it is easily accessible and within reach of necessary wiring.
- Use the provided mounting hardware to securely attach the intercom unit to a desktop or wall surface.
3.2 Cablaggio
The system requires hardwiring and is powered by a 12V power supply (e.g., Aiphone PS-1225UL, sold separately).
- Alimentazione elettrica: Connect the 12V power supply to the designated terminals on the LEF-10S.
- Connessioni Intercom: Connect the LEF-10S to door, sub-master, or other master intercoms using appropriate wiring. Maximum distance from door/sub to master is 650 ft. using 22 AWG wire, or 1,600 ft. using 18 AWG wire.
- Collegamento del battente della porta: For door access control, connect an electric strike (sold separately) via an Aiphone RY-PA relay (sold separately). Each intercom in the system must be connected to an Aiphone RY-PA relay.
- All-Call Functionality: To enable the All-Call broadcast feature, connect an Aiphone BG-10C adapter (sold separately) to the system.
- Dispositivi aggiuntivi: The RY-PA relay can also connect other devices such as CCTV cameras and lights (sold separately).
4. Impostazione
4.1 Accensione iniziale
Once all wiring is complete and secure, connect the 12V power supply to an electrical outlet. The intercom system will power on.
4.2 Regolazione del volume
The chime and audio volume can be adjusted using the dedicated controls on the master intercom unit. Adjust to a comfortable listening level.
5. Funzionamento
5.1 Effettuare una chiamata
- Press one of the 10 selectable buttons corresponding to the desired door or sub-master intercom. An LED indicator will illuminate.
- Premere e tenere premuto il tasto Premi per parlare button to speak.
- Rilasciare il Premi per parlare pulsante per ascoltare una risposta.
5.2 Ricezione di una chiamata
When a call is received from a sub-master intercom, a momentary chime will sound, and the corresponding LED indicator above the selectable button will illuminate for 20 seconds.
- Press the illuminated button to establish communication.
- Premere e tenere premuto il tasto Premi per parlare button to speak, and release to listen.
5.3 All-Call Function
If an Aiphone BG-10C adapter is connected, the All-Chiamata button allows you to broadcast a message to every intercom connected to the system.
- Premere il tasto All-Chiamata pulsante.
- Premere e tenere premuto il tasto Premi per parlare button to broadcast your message.
- Rilasciare il Premi per parlare al termine.
5.4 Funzione di rilascio della porta
If an electric strike is connected via an RY-PA relay, the Apriporta button allows you to remotely unlock the entrance for a visitor.
- Establish communication with the door intercom.
- Premere il tasto Apriporta button to activate the electric strike.
5.5 Privacy Function
IL Riservatezza button prevents other intercom users in the system from overhearing a conversation with another intercom, ensuring confidentiality.
- During a conversation, press the Riservatezza button to activate privacy mode.
- Premere il tasto Riservatezza nuovamente il pulsante per disattivarlo.
5.6 Funzione di monitoraggio
The master intercom allows you to listen to audio transmissions from a specified door or sub-master intercom at any time.
- Select the desired door or sub-master intercom button.
- The master intercom will monitor audio from that location without requiring the Premi per parlare button to be held.
5.7 Silencing Chime Alerts
To temporarily silence incoming call chime alerts, switch the power button to the 'off' position. This will only silence the chime, not power down the unit entirely.
6. Manutenzione
6.1 Pulizia
To clean the intercom unit, gently wipe the surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the unit.
6.2 Controlli regolari
Periodically check all wiring connections to ensure they are secure. Ensure the unit is free from dust accumulation, especially around vents or speaker grilles.
7. Risoluzione Dei Problemi
If you experience issues with your Aiphone LEF-10S intercom, consider the following common troubleshooting steps:
- Nessun potere: Ensure the 12V power supply is correctly connected and plugged into a working electrical outlet. Check all power connections.
- Nessuna comunicazione: Verify that all intercom units are properly wired and connected. Check for loose or damaged wiring. Ensure the correct intercom button is selected.
- Scarsa qualità audio: Adjust the audio volume. Check for any obstructions near the microphone or speaker. Ensure wiring connections are secure and free from interference.
- Apertura porta non funzionante: Confirm that the Aiphone RY-PA relay and electric strike are correctly installed and wired. Check the power supply to the electric strike.
- All-Call Not Working: Ensure the Aiphone BG-10C adapter is correctly installed and connected to the system.
If problems persist after attempting these steps, please contact Aiphone customer support or a qualified technician.
8. Specifiche
| Specificazione | Dettaglio |
|---|---|
| Dimensioni complessive (A x L x P) | 8-1/8 x 7-1/2 x 2-3/16 inches (approx. 20.6 x 19.1 x 5.6 cm) |
| Uscita di comunicazione (ricezione) | 800 mW a 20 ohm |
| Uscita di comunicazione (trasmissione) | 500 mW a 20 ohm |
| Max. Distance (Door/Sub to Master, 22 AWG) | 650 piedi (circa 198 metri) |
| Max. Distance (Door/Sub to Master, 18 AWG) | 1,600 piedi (circa 488 metri) |
| Collegamento del battente della porta | Aiphone RY-PA relay (sold separately) |
| Requisiti di potenza | Alimentatore Aiphone PS-1225UL 12V (venduto separatamente) |
| Tipo di montaggio | Montaggio in superficie |
| Materiale dell'alloggiamento | Plastica bianca |
9. Garanzia e supporto
For detailed warranty information, please refer to the documentation included with your purchase or visit the official Aiphone website. Aiphone meets International Organization for Standardization (ISO) standards 9001 and 14001.
For technical support, troubleshooting assistance beyond this manual, or to inquire about replacement parts, please contact Aiphone customer service directly.